在全膝关节置换术中同时评估胫股和髌股力学:一种实验和计算相结合的方法。

IF 1.7 4区 医学 Q4 BIOPHYSICS Journal of Biomechanical Engineering-Transactions of the Asme Pub Date : 2024-01-01 DOI:10.1115/1.4063950
Yashar A Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W Clary
{"title":"在全膝关节置换术中同时评估胫股和髌股力学:一种实验和计算相结合的方法。","authors":"Yashar A Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W Clary","doi":"10.1115/1.4063950","DOIUrl":null,"url":null,"abstract":"<p><p>Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and midflexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for the baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root-mean-square errors (RMSE) for P-F kinematics ranging from 0.8 deg to 3.3 deg and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. By simultaneously controlling dynamic, physiological loading of the T-F and P-F joint, this novel experimental simulation and validated model will be a valuable tool for investigation of future TKA designs and surgical techniques.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach.\",\"authors\":\"Yashar A Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W Clary\",\"doi\":\"10.1115/1.4063950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and midflexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for the baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root-mean-square errors (RMSE) for P-F kinematics ranging from 0.8 deg to 3.3 deg and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. By simultaneously controlling dynamic, physiological loading of the T-F and P-F joint, this novel experimental simulation and validated model will be a valuable tool for investigation of future TKA designs and surgical techniques.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063950\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063950","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

当代全膝关节置换术(TKA)尚未完全恢复整个患者群体的自然P-F力学。先前的实验模拟在创建动态、无约束、肌肉驱动的P-F关节同时控制胫股(T-F)接触力学的能力方面受到限制。本研究的目的是开发和验证一种新的实验模拟和相应的有限元模型,以评估T-F和P-F力学。在模拟深膝关节弯曲过程中,对商用磨损模拟器进行定制夹具改造,以评估髌骨高度变化的全膝TKA力学性能。开发了相应的动态有限元模型,以根据实验测量验证运动学和动力学预测。高位髌骨在早期和中期屈曲时减少了P-F反作用力,相应地,T-F力的增加表明伸肌机构效率的增加。由于在alta条件下,伸肌机构在更深屈曲中的包裹减少,在baja和alta情况下,屈曲时的峰值P-F力分别从施加的股四头肌负荷的101%增加到135%。在实验和模型预测之间观察到强烈的一致性,P-F运动学的均方根误差(RMSE)在0.8&;amp#176;至3.3&;amp#176;P-F力的RMSE范围为7.4N至53.6N。这种新的实验模拟和验证模型将为TKA植入物的未来发展提供有用的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach.

Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and midflexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for the baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root-mean-square errors (RMSE) for P-F kinematics ranging from 0.8 deg to 3.3 deg and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. By simultaneously controlling dynamic, physiological loading of the T-F and P-F joint, this novel experimental simulation and validated model will be a valuable tool for investigation of future TKA designs and surgical techniques.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
期刊最新文献
Image-Based Estimation of Left Ventricular Myocardial Stiffness. Phenomenological Muscle Constitutive Model With Actin-Titin Binding for Simulating Active Stretching. Regulatory Role of Collagen XI in the Establishment of Mechanical Properties of Tendons and Ligaments in Mice Is Tissue Dependent. Study of the Mechanism of Perceived Rotational Acceleration of a Bionic Semicircular Canal on the Basis of the "Circular Geometry Hypothesis". Walking Slope and Heavy Backpacks Affect Peak and Impulsive Lumbar Joint Contact Forces.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1