LC-MS/MS法测定血清中十氯酮含量及检测下限的重要性。

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography B Pub Date : 2023-10-29 DOI:10.1016/j.jchromb.2023.123915
Souleiman El Balkhi , Franck Saint-Marcoux
{"title":"LC-MS/MS法测定血清中十氯酮含量及检测下限的重要性。","authors":"Souleiman El Balkhi ,&nbsp;Franck Saint-Marcoux","doi":"10.1016/j.jchromb.2023.123915","DOIUrl":null,"url":null,"abstract":"<div><p>Chlordecone is an organochlorine insecticide that has been used intensively from 1973 to 1993 in the French West Indies banana fields to control root borers. This use has resulted in persistent pollution of soils and waters, and people have been and are still exposed mainly through food. Epidemiological studies showed that this exposure is associated with health disorders, including prostate cancer, prematurity, cognitive or motor development. The measurement of chlordecone in serum is considered as the best surrogate, though no clear and definitive cut-off value has been established. This renders necessary the development of analytical methods with the lowest limit of detection as possible. While most published methods have utilized GC–MS or GC–MS/MS, in the present study we report an LC-MS/MS method based on a simple QuEChERS salts extraction. The whole procedure was validated according to ISO 15189 requirements and reached LOD and LOQ values of 0.007 and 0.02 µg/L, respectively. It was applied to more 10 000 serum samples of French Indies inhabitants. More than a half had a concentration below 0.1 µg/L and more than one third of them exhibiting a concentration below 0.05 µg/L. The capability of this LC-MS/MS method to detect very low concentrations highlights its utility in exploring the health impact of chlordecone.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1230 ","pages":"Article 123915"},"PeriodicalIF":2.8000,"publicationDate":"2023-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chlordecone determination in serum by LC-MS/MS and the importance of low limit of detection\",\"authors\":\"Souleiman El Balkhi ,&nbsp;Franck Saint-Marcoux\",\"doi\":\"10.1016/j.jchromb.2023.123915\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Chlordecone is an organochlorine insecticide that has been used intensively from 1973 to 1993 in the French West Indies banana fields to control root borers. This use has resulted in persistent pollution of soils and waters, and people have been and are still exposed mainly through food. Epidemiological studies showed that this exposure is associated with health disorders, including prostate cancer, prematurity, cognitive or motor development. The measurement of chlordecone in serum is considered as the best surrogate, though no clear and definitive cut-off value has been established. This renders necessary the development of analytical methods with the lowest limit of detection as possible. While most published methods have utilized GC–MS or GC–MS/MS, in the present study we report an LC-MS/MS method based on a simple QuEChERS salts extraction. The whole procedure was validated according to ISO 15189 requirements and reached LOD and LOQ values of 0.007 and 0.02 µg/L, respectively. It was applied to more 10 000 serum samples of French Indies inhabitants. More than a half had a concentration below 0.1 µg/L and more than one third of them exhibiting a concentration below 0.05 µg/L. The capability of this LC-MS/MS method to detect very low concentrations highlights its utility in exploring the health impact of chlordecone.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":\"1230 \",\"pages\":\"Article 123915\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2023-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023223003252\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023223003252","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

十氯酮是一种有机氯杀虫剂,从1973年到1993年,它在法属西印度群岛的香蕉田里被大量使用,以控制蛀虫。这种使用导致了土壤和水域的持续污染,人们过去和现在主要通过食物接触。流行病学研究表明,这种接触与健康障碍有关,包括前列腺癌症、早产、认知或运动发育。血清中十氯酮的测量被认为是最好的替代品,尽管还没有确定明确的临界值。这使得有必要开发检测极限尽可能低的分析方法。虽然大多数已发表的方法都使用了GC-MS或GC-MS/MS,但在本研究中,我们报道了一种基于简单QuEChERS盐提取的LC-MS/MS方法。整个过程根据ISO 15189要求进行了验证,LOD和LOQ值分别达到0.007和0.02µg/L。它被应用于10000多份法属印度群岛居民的血清样本。超过一半的浓度低于0.1µg/L,超过三分之一的浓度低于0.05µg/L。这种LC-MS/MS方法检测极低浓度的能力突出了它在探索十氯酮对健康影响方面的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Chlordecone determination in serum by LC-MS/MS and the importance of low limit of detection

Chlordecone is an organochlorine insecticide that has been used intensively from 1973 to 1993 in the French West Indies banana fields to control root borers. This use has resulted in persistent pollution of soils and waters, and people have been and are still exposed mainly through food. Epidemiological studies showed that this exposure is associated with health disorders, including prostate cancer, prematurity, cognitive or motor development. The measurement of chlordecone in serum is considered as the best surrogate, though no clear and definitive cut-off value has been established. This renders necessary the development of analytical methods with the lowest limit of detection as possible. While most published methods have utilized GC–MS or GC–MS/MS, in the present study we report an LC-MS/MS method based on a simple QuEChERS salts extraction. The whole procedure was validated according to ISO 15189 requirements and reached LOD and LOQ values of 0.007 and 0.02 µg/L, respectively. It was applied to more 10 000 serum samples of French Indies inhabitants. More than a half had a concentration below 0.1 µg/L and more than one third of them exhibiting a concentration below 0.05 µg/L. The capability of this LC-MS/MS method to detect very low concentrations highlights its utility in exploring the health impact of chlordecone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
期刊最新文献
Development and validation of a robust RP-HPLC method to quantitate residual 2-mercaptoethylamine in drug product formulations containing amino acid additives. Unraveling the molecular mechanism of aqueous extract of Sargentodoxa cuneata against ulcerative colitis from serum metabolomics and bioinformatics perspectives. Green RP-HPLC method for the estimation of carfilzomib in bulk, protein nanocarriers and human plasma: Application of chemometrics and Monte-Carlo simulations Methylated magnetic covalent organic framework for sample preparation and LC-MS/MS detection of 12 tadalafil analogs in dietary supplements Progress in the technology of solvent flotation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1