{"title":"校正用于测量时间光调制的光度计的设备","authors":"PR Dekker, A.L. van Bloois","doi":"10.1177/14771535231159289","DOIUrl":null,"url":null,"abstract":"A facility for calibration of temporal light modulation (TLM) photometers has been developed. The facility is based on a laser-fed reference integrating sphere source, the optical input power of which can be modulated with an acousto-optic modulator. A system of photodiodes, amplifiers and an analogue-to-digital converter is used to sample the temporally modulated irradiance at one of the exit ports of the source. With the facility, a TLM photometer was calibrated for display contrast ratio root mean square with an absolute combined standard uncertainty of 0.037%. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility is shown to be sufficient to accommodate measurements of flicker and the stroboscopic effect.","PeriodicalId":18133,"journal":{"name":"Lighting Research & Technology","volume":"35 9 1","pages":"414 - 419"},"PeriodicalIF":2.1000,"publicationDate":"2023-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Facility for calibration of photometers for measurement of temporal light modulation\",\"authors\":\"PR Dekker, A.L. van Bloois\",\"doi\":\"10.1177/14771535231159289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A facility for calibration of temporal light modulation (TLM) photometers has been developed. The facility is based on a laser-fed reference integrating sphere source, the optical input power of which can be modulated with an acousto-optic modulator. A system of photodiodes, amplifiers and an analogue-to-digital converter is used to sample the temporally modulated irradiance at one of the exit ports of the source. With the facility, a TLM photometer was calibrated for display contrast ratio root mean square with an absolute combined standard uncertainty of 0.037%. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility is shown to be sufficient to accommodate measurements of flicker and the stroboscopic effect.\",\"PeriodicalId\":18133,\"journal\":{\"name\":\"Lighting Research & Technology\",\"volume\":\"35 9 1\",\"pages\":\"414 - 419\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lighting Research & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/14771535231159289\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/14771535231159289","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Facility for calibration of photometers for measurement of temporal light modulation
A facility for calibration of temporal light modulation (TLM) photometers has been developed. The facility is based on a laser-fed reference integrating sphere source, the optical input power of which can be modulated with an acousto-optic modulator. A system of photodiodes, amplifiers and an analogue-to-digital converter is used to sample the temporally modulated irradiance at one of the exit ports of the source. With the facility, a TLM photometer was calibrated for display contrast ratio root mean square with an absolute combined standard uncertainty of 0.037%. In addition, the facility has been characterised with the aim of measuring flicker and stroboscopic effect, considering the Ecodesign ‘Single Lighting Regulation’. The frequency response of the facility is shown to be sufficient to accommodate measurements of flicker and the stroboscopic effect.
期刊介绍:
Lighting Research & Technology (LR&T) publishes original peer-reviewed research on all aspects of light and lighting and is published in association with The Society of Light and Lighting. LR&T covers the human response to light, the science of light generation, light control and measurement plus lighting design for both interior and exterior environments, as well as daylighting, energy efficiency and sustainability