Warangkana Juangjandee, Vicki Stevenson, Eshrar Latif
{"title":"KEY FACTORS OF OCCUPANTS’ BEHAVIOUR CHARACTERISTICS AND INDOOR AIR QUALITY PERCEPTION ON OCCUPANCY COMFORT IN MULTISTOREY RESIDENTIAL BUILDINGS IN THAILAND","authors":"Warangkana Juangjandee, Vicki Stevenson, Eshrar Latif","doi":"10.2495/arc220061","DOIUrl":null,"url":null,"abstract":"Multi-storey residential buildings in high-density urban areas, especially in a tropical climate like Thailand, tend to suffer poorer indoor environmental quality. Such a significant impact increases the risks of health issues. However, there has been little study exploring the reason and identifying potential solutions. This research tackles the problems of thermal comfort and indoor air quality (IAQ) in multi-storey residential buildings in high-density urban areas (2,400 people/km 2 ) in Chiang Mai, Thailand (equatorial, winter dry climate). The survey explored occupants’ behaviour characteristics in relation to their indoor air quality and comfort perceptions. 482 responses from adult occupants were received (400 responses were required for results to have a 95% confidence level). Cronbach’s alpha, Spearman’s rank, Pearson correlation coefficient and stepwise multiple regression analysis methods were applied to analyse data; the five key results are summarised as follows: (1) five critical factors for overall comfort satisfaction were identified as temperature, natural lighting, ventilation, room privacy, and humidity (in order of importance); (2) activities which generate moisture (e.g., washing clothes, hanging clothes to dry, cooking) have a strong negative correlation with IAQ perception; (3) factors such as natural lighting and ventilation had a significant positive relationship with IAQ, while humidity and mould had a negative relationship with the IAQ; (4) natural lighting and air freshness were the strongest influences on occupant’s humidity comfort; and (5) ventilation and air freshness positively correlate with ventilation comfort, whereas humidity negatively correlated with the comfort (at a significant level). This study proposes design guidelines to improve the comfort. Built environment professionals from Thailand will be consulted on the proposed design, which may assist architects and engineers in generating IAQ improvement for their occupants, achieving indoor comfort.","PeriodicalId":23773,"journal":{"name":"WIT Transactions on the Built Environment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"WIT Transactions on the Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/arc220061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在高密度的城市地区,尤其是像泰国这样的热带气候地区,多层住宅的室内环境质量往往较差。如此重大的影响增加了健康问题的风险。然而,很少有研究探讨原因和确定潜在的解决方案。本研究解决了泰国清迈(赤道,冬季干燥气候)高密度城市地区(2400人/平方公里)多层住宅的热舒适和室内空气质量(IAQ)问题。该调查探讨了居住者的行为特征与室内空气质量和舒适度的关系。收到了来自成年住户的482份回复(需要400份回复,结果才有95%的置信度)。采用Cronbach’s alpha、Spearman’s rank、Pearson相关系数及逐步多元回归分析方法对数据进行分析;五个关键结果总结如下:(1)确定了整体舒适度满意度的五个关键因素:温度、自然采光、通风、房间隐私和湿度(按重要性排序);(2)产生湿气的活动(如洗衣服、晾衣服、做饭)与室内空气质素感知呈强烈负相关;(3)自然采光、通风与室内空气质量呈显著正相关,湿度、霉菌与室内空气质量呈显著负相关;(4)自然采光和空气清新度对居住者湿度舒适度的影响最大;(5)通风量和空气清新度与通风舒适度正相关,湿度与舒适度负相关(显著水平)。本研究提出了改善舒适性的设计准则。来自泰国的建筑环境专业人士将就拟议的设计进行咨询,这可能有助于建筑师和工程师为其居住者改善室内空气质量,实现室内舒适。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
KEY FACTORS OF OCCUPANTS’ BEHAVIOUR CHARACTERISTICS AND INDOOR AIR QUALITY PERCEPTION ON OCCUPANCY COMFORT IN MULTISTOREY RESIDENTIAL BUILDINGS IN THAILAND
Multi-storey residential buildings in high-density urban areas, especially in a tropical climate like Thailand, tend to suffer poorer indoor environmental quality. Such a significant impact increases the risks of health issues. However, there has been little study exploring the reason and identifying potential solutions. This research tackles the problems of thermal comfort and indoor air quality (IAQ) in multi-storey residential buildings in high-density urban areas (2,400 people/km 2 ) in Chiang Mai, Thailand (equatorial, winter dry climate). The survey explored occupants’ behaviour characteristics in relation to their indoor air quality and comfort perceptions. 482 responses from adult occupants were received (400 responses were required for results to have a 95% confidence level). Cronbach’s alpha, Spearman’s rank, Pearson correlation coefficient and stepwise multiple regression analysis methods were applied to analyse data; the five key results are summarised as follows: (1) five critical factors for overall comfort satisfaction were identified as temperature, natural lighting, ventilation, room privacy, and humidity (in order of importance); (2) activities which generate moisture (e.g., washing clothes, hanging clothes to dry, cooking) have a strong negative correlation with IAQ perception; (3) factors such as natural lighting and ventilation had a significant positive relationship with IAQ, while humidity and mould had a negative relationship with the IAQ; (4) natural lighting and air freshness were the strongest influences on occupant’s humidity comfort; and (5) ventilation and air freshness positively correlate with ventilation comfort, whereas humidity negatively correlated with the comfort (at a significant level). This study proposes design guidelines to improve the comfort. Built environment professionals from Thailand will be consulted on the proposed design, which may assist architects and engineers in generating IAQ improvement for their occupants, achieving indoor comfort.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
0
期刊最新文献
PROMOTING SYSTEM SAFETY AND RELIABILITY THROUGH RISK QUANTIFICATION/VISUALISATION METHODOLOGY PEDESTRIAN MOBILITY IN THE PROXIMITY OF CONSTRUCTION SITES: AN APPROACH TO ANALYSE AND IMPROVE THE PEDESTRIAN EXPERIENCE ANALYTICAL MODEL FOR ASSESSING THE RESILIENCE OF CROSS-BORDER CRITICAL TRANSPORTATION INFRASTRUCTURE CAN WE ASSESS LANDSLIDE HAZARDS IN THE VOLCANIC CRATER OF LAKE ALBANO, ROME, ITALY? GEOSTATISTICAL MODELING OF SEISMIC ACTIONS ON THE STRUCTURAL COMPONENTS OF THE SAN BENEDETTO ROAD TUNNEL, ITALY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1