医生办公室的胆固醇检测:准确性评估。

N. Rifai, M. Iosefsohn, J. Hicks
{"title":"医生办公室的胆固醇检测:准确性评估。","authors":"N. Rifai, M. Iosefsohn, J. Hicks","doi":"10.1001/ARCHPEDI.1991.02160100019009","DOIUrl":null,"url":null,"abstract":"Sir.—To assess the quality of cholesterol testing performed outside hospital laboratories and reference clinical laboratories, we evaluated the accuracy of cholesterol measurement in 33 pediatricians' offices in the Washington, DC, metropolitan area. The participating pediatricians responded to a survey we conducted locally to determine the number of pediatricians performing cholesterol testing. Seventy-one of the 116 responding pediatricians performed cholesterol testing routinely in their practices. Sixty-five percent of those pediatricians participated in this study. Materials and Methods.—Four frozen specimens, duplicate sets of two samples with cholesterol concentrations of 4.46 and 6.55 mmol/L, were sent to every participating pediatrician. The cholesterol concentrations of the samples were unknown to the pediatricians. The cholesterol concentrations of these sets were determined using an analyzer (Kodak Ektachem 700, Eastman Kodak Co, Rochester, NY) certified by the Centers for Disease Control—Reference Method Laboratory Network for cholesterol testing. Physicians were asked to thaw and twice analyze","PeriodicalId":7654,"journal":{"name":"American journal of diseases of children","volume":"1 1","pages":"1087-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cholesterol testing in the physician's office: accuracy assessment.\",\"authors\":\"N. Rifai, M. Iosefsohn, J. Hicks\",\"doi\":\"10.1001/ARCHPEDI.1991.02160100019009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sir.—To assess the quality of cholesterol testing performed outside hospital laboratories and reference clinical laboratories, we evaluated the accuracy of cholesterol measurement in 33 pediatricians' offices in the Washington, DC, metropolitan area. The participating pediatricians responded to a survey we conducted locally to determine the number of pediatricians performing cholesterol testing. Seventy-one of the 116 responding pediatricians performed cholesterol testing routinely in their practices. Sixty-five percent of those pediatricians participated in this study. Materials and Methods.—Four frozen specimens, duplicate sets of two samples with cholesterol concentrations of 4.46 and 6.55 mmol/L, were sent to every participating pediatrician. The cholesterol concentrations of the samples were unknown to the pediatricians. The cholesterol concentrations of these sets were determined using an analyzer (Kodak Ektachem 700, Eastman Kodak Co, Rochester, NY) certified by the Centers for Disease Control—Reference Method Laboratory Network for cholesterol testing. Physicians were asked to thaw and twice analyze\",\"PeriodicalId\":7654,\"journal\":{\"name\":\"American journal of diseases of children\",\"volume\":\"1 1\",\"pages\":\"1087-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of diseases of children\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1001/ARCHPEDI.1991.02160100019009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of diseases of children","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1001/ARCHPEDI.1991.02160100019009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

先生:为了评估在医院实验室和参考临床实验室之外进行的胆固醇检测的质量,我们评估了华盛顿特区大都会地区33个儿科医生办公室胆固醇测量的准确性。参与的儿科医生回答了我们在当地进行的一项调查,以确定进行胆固醇测试的儿科医生的数量。116名接受调查的儿科医生中,有71人在执业过程中例行进行胆固醇检测。65%的儿科医生参与了这项研究。材料与方法。- 4份冷冻标本,每组2份,胆固醇浓度分别为4.46和6.55 mmol/L,发送给每位参与研究的儿科医生。儿科医生不知道样本中的胆固醇浓度。这些样品的胆固醇浓度使用经疾病控制中心胆固醇检测参考方法实验室网络认证的分析仪(Kodak Ektachem 700, Eastman Kodak Co, Rochester, NY)进行测定。医生被要求解冻并进行两次分析
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cholesterol testing in the physician's office: accuracy assessment.
Sir.—To assess the quality of cholesterol testing performed outside hospital laboratories and reference clinical laboratories, we evaluated the accuracy of cholesterol measurement in 33 pediatricians' offices in the Washington, DC, metropolitan area. The participating pediatricians responded to a survey we conducted locally to determine the number of pediatricians performing cholesterol testing. Seventy-one of the 116 responding pediatricians performed cholesterol testing routinely in their practices. Sixty-five percent of those pediatricians participated in this study. Materials and Methods.—Four frozen specimens, duplicate sets of two samples with cholesterol concentrations of 4.46 and 6.55 mmol/L, were sent to every participating pediatrician. The cholesterol concentrations of the samples were unknown to the pediatricians. The cholesterol concentrations of these sets were determined using an analyzer (Kodak Ektachem 700, Eastman Kodak Co, Rochester, NY) certified by the Centers for Disease Control—Reference Method Laboratory Network for cholesterol testing. Physicians were asked to thaw and twice analyze
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Picture of the month. Picture of the month. Picture of the month. Picture of the month. Fifth disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1