利用热成像技术估算能源足迹

IF 0.7 Q4 TELECOMMUNICATIONS GetMobile-Mobile Computing & Communications Review Pub Date : 2020-01-10 DOI:10.1145/3379092.3379094
Huber Flores, Jonatan Hamberg, Xin Li, Titti Malmivirta, Agustin Zuniga, Eemil Lagerspetz, P. Nurmi
{"title":"利用热成像技术估算能源足迹","authors":"Huber Flores, Jonatan Hamberg, Xin Li, Titti Malmivirta, Agustin Zuniga, Eemil Lagerspetz, P. Nurmi","doi":"10.1145/3379092.3379094","DOIUrl":null,"url":null,"abstract":"With great power comes - besides great responsibility - big energy drain, especially where Internet of Things (IoT) devices are considered. Indeed, despite significant improvements in design and manufacturing, energy efficiency remains a critical design consideration for IoT, particularly for devices operating continuous sensing. The energy footprint of these devices has traditionally been measured using hardware power monitors (such as Monsoon power meter), which provide an accurate view of instantaneous power use. However, power meters require direct connection with the device's power source (such as battery) and hence can be used to measure energy drain only on devices with detachable power sources.","PeriodicalId":29918,"journal":{"name":"GetMobile-Mobile Computing & Communications Review","volume":"36 1","pages":"5 - 8"},"PeriodicalIF":0.7000,"publicationDate":"2020-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Estimating Energy Footprint Using Thermal Imaging\",\"authors\":\"Huber Flores, Jonatan Hamberg, Xin Li, Titti Malmivirta, Agustin Zuniga, Eemil Lagerspetz, P. Nurmi\",\"doi\":\"10.1145/3379092.3379094\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With great power comes - besides great responsibility - big energy drain, especially where Internet of Things (IoT) devices are considered. Indeed, despite significant improvements in design and manufacturing, energy efficiency remains a critical design consideration for IoT, particularly for devices operating continuous sensing. The energy footprint of these devices has traditionally been measured using hardware power monitors (such as Monsoon power meter), which provide an accurate view of instantaneous power use. However, power meters require direct connection with the device's power source (such as battery) and hence can be used to measure energy drain only on devices with detachable power sources.\",\"PeriodicalId\":29918,\"journal\":{\"name\":\"GetMobile-Mobile Computing & Communications Review\",\"volume\":\"36 1\",\"pages\":\"5 - 8\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2020-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"GetMobile-Mobile Computing & Communications Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3379092.3379094\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"TELECOMMUNICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"GetMobile-Mobile Computing & Communications Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3379092.3379094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"TELECOMMUNICATIONS","Score":null,"Total":0}
引用次数: 8

摘要

除了巨大的责任之外,巨大的能量消耗也随之而来,尤其是考虑到物联网(IoT)设备。事实上,尽管在设计和制造方面有了重大改进,但能源效率仍然是物联网设计的关键考虑因素,特别是对于运行连续传感的设备。这些设备的能源足迹传统上是使用硬件电源监视器(如Monsoon功率计)来测量的,它提供了即时电力使用的准确视图。然而,功率表需要直接连接设备的电源(如电池),因此只能用于测量具有可拆卸电源的设备的能量消耗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimating Energy Footprint Using Thermal Imaging
With great power comes - besides great responsibility - big energy drain, especially where Internet of Things (IoT) devices are considered. Indeed, despite significant improvements in design and manufacturing, energy efficiency remains a critical design consideration for IoT, particularly for devices operating continuous sensing. The energy footprint of these devices has traditionally been measured using hardware power monitors (such as Monsoon power meter), which provide an accurate view of instantaneous power use. However, power meters require direct connection with the device's power source (such as battery) and hence can be used to measure energy drain only on devices with detachable power sources.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
34
期刊最新文献
Acoustic Localization of Drones in Precise Landing: The Research and Practice with MicNest An Overview of 3GPP Standardization for Extended Reality (XR) in 5G and Beyond Community-Driven Mobile and Ubiquitous Computing A New Design Paradigm for Polymorphic Backscatter Radios Leakyscatter: Scaling Wireless Backscatter Above 100 GHz
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1