{"title":"灭菌设施中工人接触瞬时排放环氧乙烷的测定","authors":"K. Yoshida, H. E. Bryant, N. Visser, M. Atiemo","doi":"10.1080/08828032.1989.10390416","DOIUrl":null,"url":null,"abstract":"Abstract In typical hospital settings, sterilizer operators can be exposed to extremely high concentrations of ethylene oxide (EtO) for very short time periods, although calculated values of time-weighted average exposure are usually below occupational exposure limits. This is a result of an extended average time and because of the absence of an appropriate sampling method to determine EtO concentrations for extremely short periods. The purpose of the study was to determine actual peak values of EtO emission and the time delay of peak values in routine sterilizer operations. A province wide survey included 26 exposure episodes at 18 hospitals where EtO sterilizers were routinely used. A remote-controlled sequential sampler with air bags was used to sample ambient air for 3 to 5 seconds. An infrared spectrophotometer was used to determine the EtO concentrations. Peak EtO concentrations occurred 20 seconds after the doors of portable and tabletop sterilizers were opened; however, there was a considerable de...","PeriodicalId":8049,"journal":{"name":"Applied Industrial Hygiene","volume":"38 1","pages":"166-170"},"PeriodicalIF":0.0000,"publicationDate":"1989-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Determination of Worker Exposure to Instantaneously Emitted Ethylene Oxide in Sterilization Facilities\",\"authors\":\"K. Yoshida, H. E. Bryant, N. Visser, M. Atiemo\",\"doi\":\"10.1080/08828032.1989.10390416\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In typical hospital settings, sterilizer operators can be exposed to extremely high concentrations of ethylene oxide (EtO) for very short time periods, although calculated values of time-weighted average exposure are usually below occupational exposure limits. This is a result of an extended average time and because of the absence of an appropriate sampling method to determine EtO concentrations for extremely short periods. The purpose of the study was to determine actual peak values of EtO emission and the time delay of peak values in routine sterilizer operations. A province wide survey included 26 exposure episodes at 18 hospitals where EtO sterilizers were routinely used. A remote-controlled sequential sampler with air bags was used to sample ambient air for 3 to 5 seconds. An infrared spectrophotometer was used to determine the EtO concentrations. Peak EtO concentrations occurred 20 seconds after the doors of portable and tabletop sterilizers were opened; however, there was a considerable de...\",\"PeriodicalId\":8049,\"journal\":{\"name\":\"Applied Industrial Hygiene\",\"volume\":\"38 1\",\"pages\":\"166-170\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Industrial Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08828032.1989.10390416\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Industrial Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08828032.1989.10390416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of Worker Exposure to Instantaneously Emitted Ethylene Oxide in Sterilization Facilities
Abstract In typical hospital settings, sterilizer operators can be exposed to extremely high concentrations of ethylene oxide (EtO) for very short time periods, although calculated values of time-weighted average exposure are usually below occupational exposure limits. This is a result of an extended average time and because of the absence of an appropriate sampling method to determine EtO concentrations for extremely short periods. The purpose of the study was to determine actual peak values of EtO emission and the time delay of peak values in routine sterilizer operations. A province wide survey included 26 exposure episodes at 18 hospitals where EtO sterilizers were routinely used. A remote-controlled sequential sampler with air bags was used to sample ambient air for 3 to 5 seconds. An infrared spectrophotometer was used to determine the EtO concentrations. Peak EtO concentrations occurred 20 seconds after the doors of portable and tabletop sterilizers were opened; however, there was a considerable de...