{"title":"低压电缆诊断中的局部放电测量","authors":"Z. A. Tamus, R. Cselkó, I. Berta","doi":"10.1109/CEIDP.2008.4772916","DOIUrl":null,"url":null,"abstract":"Many diagnostic methods have been developed for medium and high voltage cables, but the application of these methods for low voltage cables is limited. Usually, the testing voltage is much higher than the nominal voltage of low voltage cables therefore the testing object is exposed to voltage stress. By the results of authors, the diagnostic parameters can be affected on the voltage stress [1]. The partial discharge (PD) measurement is widely used method for fault detection of PE insulated medium voltage cables. The application of PD measurement for low voltage PE cables was examined by thermally and electrically aged specimens in this paper.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"6 1","pages":"463-466"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Partial Discharge Measurement in Low Voltage Cable Diagnostics\",\"authors\":\"Z. A. Tamus, R. Cselkó, I. Berta\",\"doi\":\"10.1109/CEIDP.2008.4772916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many diagnostic methods have been developed for medium and high voltage cables, but the application of these methods for low voltage cables is limited. Usually, the testing voltage is much higher than the nominal voltage of low voltage cables therefore the testing object is exposed to voltage stress. By the results of authors, the diagnostic parameters can be affected on the voltage stress [1]. The partial discharge (PD) measurement is widely used method for fault detection of PE insulated medium voltage cables. The application of PD measurement for low voltage PE cables was examined by thermally and electrically aged specimens in this paper.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"6 1\",\"pages\":\"463-466\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Partial Discharge Measurement in Low Voltage Cable Diagnostics
Many diagnostic methods have been developed for medium and high voltage cables, but the application of these methods for low voltage cables is limited. Usually, the testing voltage is much higher than the nominal voltage of low voltage cables therefore the testing object is exposed to voltage stress. By the results of authors, the diagnostic parameters can be affected on the voltage stress [1]. The partial discharge (PD) measurement is widely used method for fault detection of PE insulated medium voltage cables. The application of PD measurement for low voltage PE cables was examined by thermally and electrically aged specimens in this paper.