{"title":"日本原子能机构高崎高级辐射研究所粒子诱导x射线发射计算机断层扫描的发展","authors":"T. Satoh","doi":"10.1142/S0129083515500151","DOIUrl":null,"url":null,"abstract":"A new micro-particle induced X-ray emission-computed tomography (PIXE-CT) system was developed at Takasaki Ion Accelerators for Advanced Radiation Application in Japan Atomic Energy Agency. In this system, scanning transmission ion microscopy-CT was performed as well as PIXE-CT for three-dimensional (3D) measurement of major elements' distributions, which are required for corrections of X-ray yields due to energy losses of projectiles and absorption of X-rays. Moreover, maximum likelihood expectation maximization algorithm has been introduced to image reconstruction because higher spatial resolution can be obtained even with less X-ray yields. Consequently, 3D distribution of trace elements in a minute biological cell less than 100 μm has been successfully obtained.","PeriodicalId":14345,"journal":{"name":"International Journal of PIXE","volume":"50 1","pages":"147-152"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Development of particle induced X-ray emission-computed tomography in Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency\",\"authors\":\"T. Satoh\",\"doi\":\"10.1142/S0129083515500151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new micro-particle induced X-ray emission-computed tomography (PIXE-CT) system was developed at Takasaki Ion Accelerators for Advanced Radiation Application in Japan Atomic Energy Agency. In this system, scanning transmission ion microscopy-CT was performed as well as PIXE-CT for three-dimensional (3D) measurement of major elements' distributions, which are required for corrections of X-ray yields due to energy losses of projectiles and absorption of X-rays. Moreover, maximum likelihood expectation maximization algorithm has been introduced to image reconstruction because higher spatial resolution can be obtained even with less X-ray yields. Consequently, 3D distribution of trace elements in a minute biological cell less than 100 μm has been successfully obtained.\",\"PeriodicalId\":14345,\"journal\":{\"name\":\"International Journal of PIXE\",\"volume\":\"50 1\",\"pages\":\"147-152\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of PIXE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S0129083515500151\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of PIXE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S0129083515500151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of particle induced X-ray emission-computed tomography in Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency
A new micro-particle induced X-ray emission-computed tomography (PIXE-CT) system was developed at Takasaki Ion Accelerators for Advanced Radiation Application in Japan Atomic Energy Agency. In this system, scanning transmission ion microscopy-CT was performed as well as PIXE-CT for three-dimensional (3D) measurement of major elements' distributions, which are required for corrections of X-ray yields due to energy losses of projectiles and absorption of X-rays. Moreover, maximum likelihood expectation maximization algorithm has been introduced to image reconstruction because higher spatial resolution can be obtained even with less X-ray yields. Consequently, 3D distribution of trace elements in a minute biological cell less than 100 μm has been successfully obtained.