用于辐射EMC/V和SE测试的混响非对称TEM电池,10 KHz-18 GHz

M. Crawford, B. Riddle
{"title":"用于辐射EMC/V和SE测试的混响非对称TEM电池,10 KHz-18 GHz","authors":"M. Crawford, B. Riddle","doi":"10.1109/ISEMC.1992.626079","DOIUrl":null,"url":null,"abstract":"This paper describes work in progress at the National Institute of Standards and Technology (NIST) to develop a single, integrated facility for electromagnetic compatibility/vulnerability (EMC/V) and shielding effectiveness (SE) testing over the frequency range of 10 kHz to 18 GHz. The facility consists of an asymmetric (offset center plate) TEM cell, 1.01 m x 1.20 m x 2.98 m in size, with two cavity mode tuners, configured as a TEM transmission line-driven, modestirred chamber. TEM test fields are generated in the chamber at frequencies below multimode cutoff (= 150 MHz), and mode-stirred test fields are generated at frequencies above multimode cutoff. The test volume in the cell is 0.5 m x 0.6 m x 0.6 m. The paper discusses the cell design, advantages and limitations for its use, the theoretical basis for its operation, and the experimental approach for its use in SE or EMC/V testing. Results are given of the evaluation of the cell's operational parameters including VSWR, E-field amplitude versus input power, tuners' effectiveness, and test volume E-field uniformity .","PeriodicalId":93568,"journal":{"name":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Reverberating Asymmetric TEM Cell For Radiated EMC/V And SE Testing, 10 KHz-18 GHz\",\"authors\":\"M. Crawford, B. Riddle\",\"doi\":\"10.1109/ISEMC.1992.626079\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes work in progress at the National Institute of Standards and Technology (NIST) to develop a single, integrated facility for electromagnetic compatibility/vulnerability (EMC/V) and shielding effectiveness (SE) testing over the frequency range of 10 kHz to 18 GHz. The facility consists of an asymmetric (offset center plate) TEM cell, 1.01 m x 1.20 m x 2.98 m in size, with two cavity mode tuners, configured as a TEM transmission line-driven, modestirred chamber. TEM test fields are generated in the chamber at frequencies below multimode cutoff (= 150 MHz), and mode-stirred test fields are generated at frequencies above multimode cutoff. The test volume in the cell is 0.5 m x 0.6 m x 0.6 m. The paper discusses the cell design, advantages and limitations for its use, the theoretical basis for its operation, and the experimental approach for its use in SE or EMC/V testing. Results are given of the evaluation of the cell's operational parameters including VSWR, E-field amplitude versus input power, tuners' effectiveness, and test volume E-field uniformity .\",\"PeriodicalId\":93568,\"journal\":{\"name\":\"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1992.626079\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1992.626079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文描述了美国国家标准与技术研究所(NIST)正在进行的一项工作,即开发一个单一的集成设备,用于在10 kHz至18 GHz的频率范围内进行电磁兼容性/脆弱性(EMC/V)和屏蔽有效性(SE)测试。该设备由一个非对称(偏移中心板)TEM单元组成,尺寸为1.01 m x 1.20 m x 2.98 m,具有两个腔模式调谐器,配置为TEM传输线驱动的调制室。实验室内在多模截止频率以下(= 150 MHz)产生TEM试验场,在多模截止频率以上产生模搅拌试验场。细胞内的测试体积为0.5 m × 0.6 m × 0.6 m。本文讨论了电池的设计、使用的优点和局限性、工作的理论基础以及在SE或EMC/V测试中使用的实验方法。给出了单元工作参数的评估结果,包括VSWR、E-field振幅与输入功率的关系、调谐器的有效性和测试体积E-field均匀性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reverberating Asymmetric TEM Cell For Radiated EMC/V And SE Testing, 10 KHz-18 GHz
This paper describes work in progress at the National Institute of Standards and Technology (NIST) to develop a single, integrated facility for electromagnetic compatibility/vulnerability (EMC/V) and shielding effectiveness (SE) testing over the frequency range of 10 kHz to 18 GHz. The facility consists of an asymmetric (offset center plate) TEM cell, 1.01 m x 1.20 m x 2.98 m in size, with two cavity mode tuners, configured as a TEM transmission line-driven, modestirred chamber. TEM test fields are generated in the chamber at frequencies below multimode cutoff (= 150 MHz), and mode-stirred test fields are generated at frequencies above multimode cutoff. The test volume in the cell is 0.5 m x 0.6 m x 0.6 m. The paper discusses the cell design, advantages and limitations for its use, the theoretical basis for its operation, and the experimental approach for its use in SE or EMC/V testing. Results are given of the evaluation of the cell's operational parameters including VSWR, E-field amplitude versus input power, tuners' effectiveness, and test volume E-field uniformity .
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
0
期刊最新文献
Reverberating Asymmetric TEM Cell For Radiated EMC/V And SE Testing, 10 KHz-18 GHz Modelling Electromagnetic Radiation From Digital Electronic Systems By Means Of The Finite Difference Time Domain Method Applying The Waveguide Below Cut-off Principle To Shielded Enclosure Design Lightning Transient Response And Margin Analysis Of Aircraft Circuits Ualification Of Radiated EMI Test Sites Using Statistical Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1