用于海水淡化的中空纤维真空膜蒸馏模块的性能表征

Justin Caspar, Guanyang Xue, Robert Krysko, A. Oztekin
{"title":"用于海水淡化的中空纤维真空膜蒸馏模块的性能表征","authors":"Justin Caspar, Guanyang Xue, Robert Krysko, A. Oztekin","doi":"10.1115/fedsm2021-65612","DOIUrl":null,"url":null,"abstract":"\n 3D laminar flow simulations were conducted using OpenFOAM to resolve the temperature, concentration, velocity, and pressure field for two hollow fiber vacuum membrane distillation configurations with feed solution flowing either inside or outside a single hollow fiber. The fiber has a circular cross-section, a fixed length of 120mm, and an inner diameter of 2 mm. The wall thickness was varied from 150 to 450μm, and the pore diameter was varied from 0.1 to 0.3μm based on commercial fibers. The feed solution is an aqueous solution of water and NaCl. The feed flow was simulated at a Reynolds number of 500 and vacuum pressure of 5,000 Pascals. It was found that there was a 75% increase in flux, from 9.58 to 41.41 kg/m2h, between the worst and the best case in membrane properties. Increasing the pore diameter or wall thickness while the other value was fixed resulted in a 45–57% flux increase depending on the fixed value. The module with the feed solution flowing outside a hollow fiber yields 24% higher flux than the module with the feed solution flowing inside the hollow fiber at the same conditions.","PeriodicalId":23636,"journal":{"name":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Characterization of Hollow Fiber Vacuum Membrane Distillation Module for Desalination\",\"authors\":\"Justin Caspar, Guanyang Xue, Robert Krysko, A. Oztekin\",\"doi\":\"10.1115/fedsm2021-65612\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n 3D laminar flow simulations were conducted using OpenFOAM to resolve the temperature, concentration, velocity, and pressure field for two hollow fiber vacuum membrane distillation configurations with feed solution flowing either inside or outside a single hollow fiber. The fiber has a circular cross-section, a fixed length of 120mm, and an inner diameter of 2 mm. The wall thickness was varied from 150 to 450μm, and the pore diameter was varied from 0.1 to 0.3μm based on commercial fibers. The feed solution is an aqueous solution of water and NaCl. The feed flow was simulated at a Reynolds number of 500 and vacuum pressure of 5,000 Pascals. It was found that there was a 75% increase in flux, from 9.58 to 41.41 kg/m2h, between the worst and the best case in membrane properties. Increasing the pore diameter or wall thickness while the other value was fixed resulted in a 45–57% flux increase depending on the fixed value. The module with the feed solution flowing outside a hollow fiber yields 24% higher flux than the module with the feed solution flowing inside the hollow fiber at the same conditions.\",\"PeriodicalId\":23636,\"journal\":{\"name\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/fedsm2021-65612\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/fedsm2021-65612","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用OpenFOAM软件进行了三维层流模拟,分析了两种中空纤维真空膜蒸馏配置下的温度、浓度、速度和压力场,其中进料溶液分别在单个中空纤维内部或外部流动。光纤截面为圆形,固定长度为120mm,内径为2mm。以商品纤维为基础,壁厚为150 ~ 450μm,孔径为0.1 ~ 0.3μm。进料液为水和NaCl的水溶液。模拟了雷诺数为500,真空压力为5000帕斯卡的进料流。结果表明,在膜性能最差和最佳情况下,通量从9.58 kg/m2h增加到41.41 kg/m2h,增加了75%。在另一个值固定的情况下,增加孔径或壁厚,根据固定值的不同,通量增加45-57%。在相同条件下,进料溶液在中空纤维外流动的模块比进料溶液在中空纤维内流动的模块的通量高24%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance Characterization of Hollow Fiber Vacuum Membrane Distillation Module for Desalination
3D laminar flow simulations were conducted using OpenFOAM to resolve the temperature, concentration, velocity, and pressure field for two hollow fiber vacuum membrane distillation configurations with feed solution flowing either inside or outside a single hollow fiber. The fiber has a circular cross-section, a fixed length of 120mm, and an inner diameter of 2 mm. The wall thickness was varied from 150 to 450μm, and the pore diameter was varied from 0.1 to 0.3μm based on commercial fibers. The feed solution is an aqueous solution of water and NaCl. The feed flow was simulated at a Reynolds number of 500 and vacuum pressure of 5,000 Pascals. It was found that there was a 75% increase in flux, from 9.58 to 41.41 kg/m2h, between the worst and the best case in membrane properties. Increasing the pore diameter or wall thickness while the other value was fixed resulted in a 45–57% flux increase depending on the fixed value. The module with the feed solution flowing outside a hollow fiber yields 24% higher flux than the module with the feed solution flowing inside the hollow fiber at the same conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fluid Dynamics and Contact Stress on Hard Sealing Surface Analysis of LNG Cryogenic Ball Valve 0D Modeling of Fuel Tank for Vapor Generation Impact of Urban Microclimate on Air Conditioning Energy Consumption Using Different Convective Heat Transfer Coefficient Correlations Available in Building Energy Simulation Tools Study on Overall Design of a Vertical Take-Off and Landing Unmanned Aerial Vehicle Powered by Electric Ducted Fans Influence of the Topological Structures of the Nose of High-Speed Maglev Train on Aerodynamic Performances
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1