刚性路面板厚度对裂缝宽度的影响分析

A. Soehardjono, Candra Aditya
{"title":"刚性路面板厚度对裂缝宽度的影响分析","authors":"A. Soehardjono, Candra Aditya","doi":"10.21303/2461-4262.2021.001693","DOIUrl":null,"url":null,"abstract":"Cracks that occur in rigid pavements include longitudinal cracks, transverse cracks, and corner cracks. The relatively large crack width not only spoils the aesthetics of the concrete structural elements but can also lead to structural failure. This study aims to determine the crack width of a rigid pavement concrete slab located above the subgrade which is considered a beam on an elastic foundation, so that a minimum rigid pavement concrete slab thickness can be recommended. The specimen will be observed at various thicknesses to obtain the optimum thickness. The load used is a centralized monotonous load, which represents the load of the truck vehicle. The research limitation is using a test object in the form of a concrete plate measuring 2000x600 mm which is placed on the ground with CBR=6 %. The quality of reinforced concrete slabs is fc'=40 MPa and fy=440.31 MPa. The thickness of the concrete slab varies between 100 mm, 150 mm, and 200 mm. The slab placed on the ground is then given a central loading in the form of a centralized monotonic load. The loading range starts from a load of 2–180 kN with a load interval of 2 kN. The experimental results show that the rigid pavement slab has a bending failure so that the crack pattern that occurs begins with the first crack on the underside of the slab. The crack pattern in terms of slab thickness variation has a similar pattern. The initial crack width on the slab is 0.04 mm. The thicker the slab smaller the crack width at the same load. Based on the maximum allowable crack width=0.3 mm. For loads between (80–100) kN (Road Class I, II, and III), a minimum thickness of rigid pavement slabs (70–80) mm is recommended. For loads between (130–140) kN, the minimum thickness of the rigid pavement slab (105–115) mm is recommended","PeriodicalId":18255,"journal":{"name":"MatSciRN: Process & Device Modeling (Topic)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of the Effect of Slab Thickness on Crack Width in Rigid Pavement Slabs\",\"authors\":\"A. Soehardjono, Candra Aditya\",\"doi\":\"10.21303/2461-4262.2021.001693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cracks that occur in rigid pavements include longitudinal cracks, transverse cracks, and corner cracks. The relatively large crack width not only spoils the aesthetics of the concrete structural elements but can also lead to structural failure. This study aims to determine the crack width of a rigid pavement concrete slab located above the subgrade which is considered a beam on an elastic foundation, so that a minimum rigid pavement concrete slab thickness can be recommended. The specimen will be observed at various thicknesses to obtain the optimum thickness. The load used is a centralized monotonous load, which represents the load of the truck vehicle. The research limitation is using a test object in the form of a concrete plate measuring 2000x600 mm which is placed on the ground with CBR=6 %. The quality of reinforced concrete slabs is fc'=40 MPa and fy=440.31 MPa. The thickness of the concrete slab varies between 100 mm, 150 mm, and 200 mm. The slab placed on the ground is then given a central loading in the form of a centralized monotonic load. The loading range starts from a load of 2–180 kN with a load interval of 2 kN. The experimental results show that the rigid pavement slab has a bending failure so that the crack pattern that occurs begins with the first crack on the underside of the slab. The crack pattern in terms of slab thickness variation has a similar pattern. The initial crack width on the slab is 0.04 mm. The thicker the slab smaller the crack width at the same load. Based on the maximum allowable crack width=0.3 mm. For loads between (80–100) kN (Road Class I, II, and III), a minimum thickness of rigid pavement slabs (70–80) mm is recommended. For loads between (130–140) kN, the minimum thickness of the rigid pavement slab (105–115) mm is recommended\",\"PeriodicalId\":18255,\"journal\":{\"name\":\"MatSciRN: Process & Device Modeling (Topic)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MatSciRN: Process & Device Modeling (Topic)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21303/2461-4262.2021.001693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MatSciRN: Process & Device Modeling (Topic)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21303/2461-4262.2021.001693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

刚性路面出现的裂缝包括纵向裂缝、横向裂缝和转角裂缝。较大的裂缝宽度不仅破坏了混凝土结构构件的美观,而且可能导致结构破坏。本研究旨在确定弹性基础上的梁位于路基上方的刚性路面混凝土板的裂缝宽度,从而推荐最小刚性路面混凝土板厚度。试样将在不同厚度下进行观察,以获得最佳厚度。所使用的荷载为集中单调荷载,代表货车的荷载。研究限制是使用混凝土板形式的测试对象,尺寸为2000x600mm,放置在地面上,CBR= 6%。钢筋混凝土板的质量为fc'=40 MPa, fy= 4400.31 MPa。混凝土板厚度为100mm、150mm、200mm。然后以集中单调荷载的形式给予放置在地面上的板一个中心荷载。加载范围从2 ~ 180kn开始,加载间隔为2kn。试验结果表明:刚性铺装板存在弯曲破坏,其开裂模式从铺装板底部的第一道裂缝开始;随着板坯厚度的变化,裂纹形态也具有相似的形态。板坯初始裂缝宽度为0.04 mm。相同荷载下,板坯越厚裂缝宽度越小。基于最大允许裂缝宽度=0.3 mm。对于(80-100)kN(道路I、II、III级)之间的荷载,建议刚性路面板的最小厚度为70-80 mm。当荷载为(130 ~ 140)kN时,建议采用最小刚性路面板厚度为(105 ~ 115)mm
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of the Effect of Slab Thickness on Crack Width in Rigid Pavement Slabs
Cracks that occur in rigid pavements include longitudinal cracks, transverse cracks, and corner cracks. The relatively large crack width not only spoils the aesthetics of the concrete structural elements but can also lead to structural failure. This study aims to determine the crack width of a rigid pavement concrete slab located above the subgrade which is considered a beam on an elastic foundation, so that a minimum rigid pavement concrete slab thickness can be recommended. The specimen will be observed at various thicknesses to obtain the optimum thickness. The load used is a centralized monotonous load, which represents the load of the truck vehicle. The research limitation is using a test object in the form of a concrete plate measuring 2000x600 mm which is placed on the ground with CBR=6 %. The quality of reinforced concrete slabs is fc'=40 MPa and fy=440.31 MPa. The thickness of the concrete slab varies between 100 mm, 150 mm, and 200 mm. The slab placed on the ground is then given a central loading in the form of a centralized monotonic load. The loading range starts from a load of 2–180 kN with a load interval of 2 kN. The experimental results show that the rigid pavement slab has a bending failure so that the crack pattern that occurs begins with the first crack on the underside of the slab. The crack pattern in terms of slab thickness variation has a similar pattern. The initial crack width on the slab is 0.04 mm. The thicker the slab smaller the crack width at the same load. Based on the maximum allowable crack width=0.3 mm. For loads between (80–100) kN (Road Class I, II, and III), a minimum thickness of rigid pavement slabs (70–80) mm is recommended. For loads between (130–140) kN, the minimum thickness of the rigid pavement slab (105–115) mm is recommended
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Interfacial Microstructure and Mechanical Behavior of Low-Temperature Diffusion Bonded Mo/SS304 Joints Using Ni xCu 1-x Interlayers An Improved Fault Current Calculation Method and Protection Scheme of Doubly-Fed Induction Generator A Dual-Tunable Ultra-Broadband Terahertz Absorber Based on Graphene and Strontium Titanate Hydrogen Concentration and Hydrides in Zircaloy-4 During Cyclic Thermomechanical Loading Flaw-Insensitive Fracture of a Micrometer-Sized Brittle Metallic Glass
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1