Shin-Chi Lai, Te-Hsuan Hung, W. Li, Yun-Syuan Jhang, Kuan-Ying Chang, Wen-Ho Juang, C. Luo
{"title":"便携式心电信号记录仪的低成本原型设计","authors":"Shin-Chi Lai, Te-Hsuan Hung, W. Li, Yun-Syuan Jhang, Kuan-Ying Chang, Wen-Ho Juang, C. Luo","doi":"10.1109/APCCAS.2016.7803922","DOIUrl":null,"url":null,"abstract":"This paper presents an acquisition system design integrated with the Arduino Nano platform and commercial ICs for the prototype development of a portable ECG signal monitor. A simply lossless ECG compression algorithm with a better Compression Ratio (CR) is employed to reduce a great amount of storage and transmission recording data. The result proves that the CR averages are 2.53 for ECG test patterns from MIT-BIH arrhythmia database. The experimental result also shows a pure ECG signal can be easily acquired by using a 16-tap low-pass digital filter. Therefore, the proposed design would be a good choice for the application of ECG signal acquisition in the future.","PeriodicalId":6495,"journal":{"name":"2016 IEEE Asia Pacific Conference on Circuits and Systems (APCCAS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Low-cost prototype design of a portable ECG signal recorder\",\"authors\":\"Shin-Chi Lai, Te-Hsuan Hung, W. Li, Yun-Syuan Jhang, Kuan-Ying Chang, Wen-Ho Juang, C. Luo\",\"doi\":\"10.1109/APCCAS.2016.7803922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an acquisition system design integrated with the Arduino Nano platform and commercial ICs for the prototype development of a portable ECG signal monitor. A simply lossless ECG compression algorithm with a better Compression Ratio (CR) is employed to reduce a great amount of storage and transmission recording data. The result proves that the CR averages are 2.53 for ECG test patterns from MIT-BIH arrhythmia database. The experimental result also shows a pure ECG signal can be easily acquired by using a 16-tap low-pass digital filter. Therefore, the proposed design would be a good choice for the application of ECG signal acquisition in the future.\",\"PeriodicalId\":6495,\"journal\":{\"name\":\"2016 IEEE Asia Pacific Conference on Circuits and Systems (APCCAS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Asia Pacific Conference on Circuits and Systems (APCCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APCCAS.2016.7803922\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Asia Pacific Conference on Circuits and Systems (APCCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APCCAS.2016.7803922","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Low-cost prototype design of a portable ECG signal recorder
This paper presents an acquisition system design integrated with the Arduino Nano platform and commercial ICs for the prototype development of a portable ECG signal monitor. A simply lossless ECG compression algorithm with a better Compression Ratio (CR) is employed to reduce a great amount of storage and transmission recording data. The result proves that the CR averages are 2.53 for ECG test patterns from MIT-BIH arrhythmia database. The experimental result also shows a pure ECG signal can be easily acquired by using a 16-tap low-pass digital filter. Therefore, the proposed design would be a good choice for the application of ECG signal acquisition in the future.