{"title":"流动注射-分光光度法测定环境水中有机磷农药","authors":"Xinfeng Xiao, Qiang Zhang, Yuan Tian, Zhaoli Wang","doi":"10.1109/MACE.2011.5988328","DOIUrl":null,"url":null,"abstract":"An automatic, convenient method combined flow injection technique for determining organic phosphorus pesticide in environment water was developed based on the inhibition effects of organic phosphorus pesticide to plant-esterase. The optimized determining conditions were acquired, and the analytical characteristics of this method were studied. The linear ranges of dichlorvos' standard curves was 0.008 ∼ 4mg/L. The linear equation of dichlorvos was U(mV) = −4874.4 C (mg/L) + 110313. The correlation coefficient of dichlorvos was 0.9984. The detection limit (S/N= 3) was 0.02mg/L for dichlorvos. The relative standard deviation (RSD) of dichlorvos was 1.04% (n=6). The recoveries ranged from 95% to 105%. The analysis result was good.","PeriodicalId":6400,"journal":{"name":"2011 Second International Conference on Mechanic Automation and Control Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of organic phosphorus pesticide in environmental water by flow injection-spectrophotometry\",\"authors\":\"Xinfeng Xiao, Qiang Zhang, Yuan Tian, Zhaoli Wang\",\"doi\":\"10.1109/MACE.2011.5988328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An automatic, convenient method combined flow injection technique for determining organic phosphorus pesticide in environment water was developed based on the inhibition effects of organic phosphorus pesticide to plant-esterase. The optimized determining conditions were acquired, and the analytical characteristics of this method were studied. The linear ranges of dichlorvos' standard curves was 0.008 ∼ 4mg/L. The linear equation of dichlorvos was U(mV) = −4874.4 C (mg/L) + 110313. The correlation coefficient of dichlorvos was 0.9984. The detection limit (S/N= 3) was 0.02mg/L for dichlorvos. The relative standard deviation (RSD) of dichlorvos was 1.04% (n=6). The recoveries ranged from 95% to 105%. The analysis result was good.\",\"PeriodicalId\":6400,\"journal\":{\"name\":\"2011 Second International Conference on Mechanic Automation and Control Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Second International Conference on Mechanic Automation and Control Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MACE.2011.5988328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Second International Conference on Mechanic Automation and Control Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MACE.2011.5988328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of organic phosphorus pesticide in environmental water by flow injection-spectrophotometry
An automatic, convenient method combined flow injection technique for determining organic phosphorus pesticide in environment water was developed based on the inhibition effects of organic phosphorus pesticide to plant-esterase. The optimized determining conditions were acquired, and the analytical characteristics of this method were studied. The linear ranges of dichlorvos' standard curves was 0.008 ∼ 4mg/L. The linear equation of dichlorvos was U(mV) = −4874.4 C (mg/L) + 110313. The correlation coefficient of dichlorvos was 0.9984. The detection limit (S/N= 3) was 0.02mg/L for dichlorvos. The relative standard deviation (RSD) of dichlorvos was 1.04% (n=6). The recoveries ranged from 95% to 105%. The analysis result was good.