反射中子对金属组件反应性测量的影响

Hui Gao, Lingli Song, Meng Li, Jie Wen, Qilin Xie
{"title":"反射中子对金属组件反应性测量的影响","authors":"Hui Gao,&nbsp;Lingli Song,&nbsp;Meng Li,&nbsp;Jie Wen,&nbsp;Qilin Xie","doi":"10.1016/j.nucana.2022.100035","DOIUrl":null,"url":null,"abstract":"<div><p>The kinetic equation including the reflected neutron effect is established based on the time-dependent two-region kinetic model. Different reactivity measurement methods are simulated by using the equation. The simulation results show the difference of estimated reactivity values between the prompt neutron decay constant method and the positive period method. It illustrates the principle of reactivity difference in measured value by using different measurement methods, that is, the time scale of the measurement method determines the contribution rate of the reflected neutrons in the experiments. The contribution rate influences the measured value of reactivity.</p></div>","PeriodicalId":100965,"journal":{"name":"Nuclear Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2773183922000350/pdfft?md5=cc574af9c5377cc30b3b28d3cfbea5e4&pid=1-s2.0-S2773183922000350-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Effects of reflected neutrons on the reactivity measurement of metal Assemblies\",\"authors\":\"Hui Gao,&nbsp;Lingli Song,&nbsp;Meng Li,&nbsp;Jie Wen,&nbsp;Qilin Xie\",\"doi\":\"10.1016/j.nucana.2022.100035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The kinetic equation including the reflected neutron effect is established based on the time-dependent two-region kinetic model. Different reactivity measurement methods are simulated by using the equation. The simulation results show the difference of estimated reactivity values between the prompt neutron decay constant method and the positive period method. It illustrates the principle of reactivity difference in measured value by using different measurement methods, that is, the time scale of the measurement method determines the contribution rate of the reflected neutrons in the experiments. The contribution rate influences the measured value of reactivity.</p></div>\",\"PeriodicalId\":100965,\"journal\":{\"name\":\"Nuclear Analysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2773183922000350/pdfft?md5=cc574af9c5377cc30b3b28d3cfbea5e4&pid=1-s2.0-S2773183922000350-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2773183922000350\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Analysis","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773183922000350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于时变双区动力学模型,建立了包含反射中子效应的动力学方程。利用该方程对不同的反应性测量方法进行了仿真。模拟结果表明,瞬发中子衰变常数法与正周期法估算的反应性值存在差异。说明了不同测量方法的反应性测量值差异的原理,即测量方法的时间尺度决定了反射中子在实验中的贡献率。贡献率影响反应性的测量值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of reflected neutrons on the reactivity measurement of metal Assemblies

The kinetic equation including the reflected neutron effect is established based on the time-dependent two-region kinetic model. Different reactivity measurement methods are simulated by using the equation. The simulation results show the difference of estimated reactivity values between the prompt neutron decay constant method and the positive period method. It illustrates the principle of reactivity difference in measured value by using different measurement methods, that is, the time scale of the measurement method determines the contribution rate of the reflected neutrons in the experiments. The contribution rate influences the measured value of reactivity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
期刊最新文献
A comparative analysis of the NaI detector response function using GAMOS and FLUKA Monte Carlo simulations Coulomb interaction dependence of optimal energy to synthesize superheavy elements Structural insights into soft matter materials via spin echo small angle neutron scattering and small angle neutron scattering Major and trace elements determination in organic and conventional Moroccan vegetables using the k0-standardisation method of neutron activation analysis Gold nanoparticle effect on dose and DNA damage enhancement in the vicinity of gold nanoparticles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1