定日镜场闭环控制系统

J. Freeman, K. Keerthi, L. R. Chandran
{"title":"定日镜场闭环控制系统","authors":"J. Freeman, K. Keerthi, L. R. Chandran","doi":"10.1109/TAPENERGY.2015.7229630","DOIUrl":null,"url":null,"abstract":"The alarming energy crisis, heightened by the continuing depletion of fossil fuels, accentuates the need for the development of renewable energy technology, knowledge, and infrastructure. A Central Receiver (Power Tower) Solar Energy system uses heliostats (motorized planar reflectors) to continuously reflect direct radiation from the sun onto a central receiver. This paper discusses a novel closed loop control system for a heliostat field. In this system, rough adjustment of the heliostat is performed using an Inertial Measurement Unit (IMU). Precision adjustment of the heliostat is performed by inducing a small mechanical vibration in the heliostat's reflective surface, using a piezoelectric actuator. This vibration creates time-dependent changes in the light waves reflected from the heliostat, which can be detected by photo-sensors surrounding the thermal receiver target. The position of misaligned heliostats can be corrected once they are identified by FFT analysis of the light waves received by the photo-sensors. This technique can, in principle, control thousands of heliostats simultaneously. The control system is coded using MATLAB.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"1 1","pages":"272-277"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Closed loop control system for a heliostat field\",\"authors\":\"J. Freeman, K. Keerthi, L. R. Chandran\",\"doi\":\"10.1109/TAPENERGY.2015.7229630\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The alarming energy crisis, heightened by the continuing depletion of fossil fuels, accentuates the need for the development of renewable energy technology, knowledge, and infrastructure. A Central Receiver (Power Tower) Solar Energy system uses heliostats (motorized planar reflectors) to continuously reflect direct radiation from the sun onto a central receiver. This paper discusses a novel closed loop control system for a heliostat field. In this system, rough adjustment of the heliostat is performed using an Inertial Measurement Unit (IMU). Precision adjustment of the heliostat is performed by inducing a small mechanical vibration in the heliostat's reflective surface, using a piezoelectric actuator. This vibration creates time-dependent changes in the light waves reflected from the heliostat, which can be detected by photo-sensors surrounding the thermal receiver target. The position of misaligned heliostats can be corrected once they are identified by FFT analysis of the light waves received by the photo-sensors. This technique can, in principle, control thousands of heliostats simultaneously. The control system is coded using MATLAB.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"1 1\",\"pages\":\"272-277\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229630\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

化石燃料的持续枯竭加剧了令人担忧的能源危机,这凸显了发展可再生能源技术、知识和基础设施的必要性。中央接收器(动力塔)太阳能系统使用定日镜(机动平面反射器)连续地将太阳的直接辐射反射到中央接收器上。本文讨论了一种新的定日镜闭环控制系统。在该系统中,利用惯性测量单元(IMU)对定日镜进行粗略调整。定日镜的精确调整是通过在定日镜的反射表面诱导一个小的机械振动来实现的,使用压电驱动器。这种振动在定日镜反射的光波中产生了随时间的变化,这可以被热接收器目标周围的光传感器检测到。一旦对光传感器接收到的光波进行FFT分析,就可以对不对准的定日镜的位置进行校正。这种技术原则上可以同时控制数千个定日镜。采用MATLAB对控制系统进行编码。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Closed loop control system for a heliostat field
The alarming energy crisis, heightened by the continuing depletion of fossil fuels, accentuates the need for the development of renewable energy technology, knowledge, and infrastructure. A Central Receiver (Power Tower) Solar Energy system uses heliostats (motorized planar reflectors) to continuously reflect direct radiation from the sun onto a central receiver. This paper discusses a novel closed loop control system for a heliostat field. In this system, rough adjustment of the heliostat is performed using an Inertial Measurement Unit (IMU). Precision adjustment of the heliostat is performed by inducing a small mechanical vibration in the heliostat's reflective surface, using a piezoelectric actuator. This vibration creates time-dependent changes in the light waves reflected from the heliostat, which can be detected by photo-sensors surrounding the thermal receiver target. The position of misaligned heliostats can be corrected once they are identified by FFT analysis of the light waves received by the photo-sensors. This technique can, in principle, control thousands of heliostats simultaneously. The control system is coded using MATLAB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduction of common mode voltage in three phase inverter A novel topology of forward-flyback PFC converter with constant on-time control Online benefit optimization in a liberalized/free microgrid market model UHVDC transmission with dedicated metallic return Bridgeless flyback converter for low power lighting application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1