信号压缩下DEPFET传感器非线性响应的评估

A. Castoldi, C. Guazzoni, S. Aschauer, L. Strüder, K. Hansen, S. Maffessanti, M. Porro
{"title":"信号压缩下DEPFET传感器非线性响应的评估","authors":"A. Castoldi, C. Guazzoni, S. Aschauer, L. Strüder, K. Hansen, S. Maffessanti, M. Porro","doi":"10.1109/NSS/MIC42677.2020.9508034","DOIUrl":null,"url":null,"abstract":"The implementation of a Depleted Field Effect Transistor (DEPFET) in each pixel of the DSSC (DEPFET Sensor with Signal Compression) X-ray camera for the European XFEL is intended to provide the appropriate signal compression at high injection levels and low noise figure. The aim of this work is the assessment of the non-linear DEPFET response. To this purpose the response of DSSC DEPFET pixels has been measured and analyzed up to 2 MeV equivalent deposited energy in the experimental conditions foreseen for the final DSSC camera. An appropriate fitting function has been introduced to predict the compression “kink” positions and to model the shape of the compression curve. The preliminary results of this study will be summarized.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"32 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of the Non-Linear Response of DEPFET Sensors with Signal Compression\",\"authors\":\"A. Castoldi, C. Guazzoni, S. Aschauer, L. Strüder, K. Hansen, S. Maffessanti, M. Porro\",\"doi\":\"10.1109/NSS/MIC42677.2020.9508034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The implementation of a Depleted Field Effect Transistor (DEPFET) in each pixel of the DSSC (DEPFET Sensor with Signal Compression) X-ray camera for the European XFEL is intended to provide the appropriate signal compression at high injection levels and low noise figure. The aim of this work is the assessment of the non-linear DEPFET response. To this purpose the response of DSSC DEPFET pixels has been measured and analyzed up to 2 MeV equivalent deposited energy in the experimental conditions foreseen for the final DSSC camera. An appropriate fitting function has been introduced to predict the compression “kink” positions and to model the shape of the compression curve. The preliminary results of this study will be summarized.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"32 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9508034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9508034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在欧洲XFEL的DSSC(带信号压缩的DEPFET传感器)x射线相机的每个像素中实现耗尽场效应晶体管(DEPFET),旨在提供高注入水平和低噪声系数下适当的信号压缩。这项工作的目的是评估非线性DEPFET响应。为此,在最终DSSC相机的实验条件下,测量和分析了DSSC DEPFET像素的响应,最高可达2 MeV的等效沉积能量。引入合适的拟合函数来预测压缩“扭结”位置,并对压缩曲线的形状进行建模。本文将对本研究的初步结果进行总结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of the Non-Linear Response of DEPFET Sensors with Signal Compression
The implementation of a Depleted Field Effect Transistor (DEPFET) in each pixel of the DSSC (DEPFET Sensor with Signal Compression) X-ray camera for the European XFEL is intended to provide the appropriate signal compression at high injection levels and low noise figure. The aim of this work is the assessment of the non-linear DEPFET response. To this purpose the response of DSSC DEPFET pixels has been measured and analyzed up to 2 MeV equivalent deposited energy in the experimental conditions foreseen for the final DSSC camera. An appropriate fitting function has been introduced to predict the compression “kink” positions and to model the shape of the compression curve. The preliminary results of this study will be summarized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1