{"title":"具有时滞的多区域互联电力系统负载频率高阶自由度控制器","authors":"CH. Naga Sai Kalyan, Chintalapudi V Suresh","doi":"10.1016/j.gltp.2022.03.020","DOIUrl":null,"url":null,"abstract":"<div><p>In this paper, a seagull optimization algorithm (SOA) based 3-Degree-of-freedom (DOF) proportional-integral-derivative (3DOFPID) controller is suggested for load frequency control of multi-area interconnected power system (MAIPS). The considered MAIPS comprises of two areas with Thermal-Hydro-Nuclear generation units in each area. Analysis has been carried out by subjugating area-1 of MAIPS with a step load disturbance (SLD) of 10%. The sovereignty of presented SOA tuned 3DOFPID in regulating the stability of MAIPS is revealed upon comparing with the performances of 2DOFPID and conventional PID controllers. MIPS is analyzed dynamically without and with considering the nonlinear realistic constraint of communication time delays (CTDs) to demonstrate its impact on load frequency control performance. Simulation results disclosed that, MAIPS dynamical behavior is slightly more deviated up on considering CTDs and is justified.</p></div>","PeriodicalId":100588,"journal":{"name":"Global Transitions Proceedings","volume":"3 1","pages":"Pages 332-337"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666285X22000267/pdfft?md5=362ca1545daa5d693f195a6c16d6d1a0&pid=1-s2.0-S2666285X22000267-main.pdf","citationCount":"19","resultStr":"{\"title\":\"Higher Order Degree of Freedom Controller for Load Frequency Control of Multi Area Interconnected Power System with Time Delays\",\"authors\":\"CH. Naga Sai Kalyan, Chintalapudi V Suresh\",\"doi\":\"10.1016/j.gltp.2022.03.020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this paper, a seagull optimization algorithm (SOA) based 3-Degree-of-freedom (DOF) proportional-integral-derivative (3DOFPID) controller is suggested for load frequency control of multi-area interconnected power system (MAIPS). The considered MAIPS comprises of two areas with Thermal-Hydro-Nuclear generation units in each area. Analysis has been carried out by subjugating area-1 of MAIPS with a step load disturbance (SLD) of 10%. The sovereignty of presented SOA tuned 3DOFPID in regulating the stability of MAIPS is revealed upon comparing with the performances of 2DOFPID and conventional PID controllers. MIPS is analyzed dynamically without and with considering the nonlinear realistic constraint of communication time delays (CTDs) to demonstrate its impact on load frequency control performance. Simulation results disclosed that, MAIPS dynamical behavior is slightly more deviated up on considering CTDs and is justified.</p></div>\",\"PeriodicalId\":100588,\"journal\":{\"name\":\"Global Transitions Proceedings\",\"volume\":\"3 1\",\"pages\":\"Pages 332-337\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666285X22000267/pdfft?md5=362ca1545daa5d693f195a6c16d6d1a0&pid=1-s2.0-S2666285X22000267-main.pdf\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Transitions Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666285X22000267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Transitions Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666285X22000267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Higher Order Degree of Freedom Controller for Load Frequency Control of Multi Area Interconnected Power System with Time Delays
In this paper, a seagull optimization algorithm (SOA) based 3-Degree-of-freedom (DOF) proportional-integral-derivative (3DOFPID) controller is suggested for load frequency control of multi-area interconnected power system (MAIPS). The considered MAIPS comprises of two areas with Thermal-Hydro-Nuclear generation units in each area. Analysis has been carried out by subjugating area-1 of MAIPS with a step load disturbance (SLD) of 10%. The sovereignty of presented SOA tuned 3DOFPID in regulating the stability of MAIPS is revealed upon comparing with the performances of 2DOFPID and conventional PID controllers. MIPS is analyzed dynamically without and with considering the nonlinear realistic constraint of communication time delays (CTDs) to demonstrate its impact on load frequency control performance. Simulation results disclosed that, MAIPS dynamical behavior is slightly more deviated up on considering CTDs and is justified.