旋转压缩机转子/定子上方油滴大小和速度的实验测量

Puyuan Wu, Jun Chen, P. Sojka, Yang Li, Hongjun Cao
{"title":"旋转压缩机转子/定子上方油滴大小和速度的实验测量","authors":"Puyuan Wu, Jun Chen, P. Sojka, Yang Li, Hongjun Cao","doi":"10.1115/fedsm2021-65874","DOIUrl":null,"url":null,"abstract":"\n Hundreds of millions of Air conditioning (AC) systems are produced each year. Many of them, especially small AC appliances, use rotary compressors as the system’s heat pump due to their simple structure and high efficiency in a small system. Lubricant oil is used in the rotary compressor to lubricate the moving parts, such as the crankshaft and the rolling piston, and to seal the clearance between the sliding parts, e.g., the clearance between the rolling piston and the cylinder, and the vane and the cylinder. As the compressed refrigerant vapor is discharged from the cylinder through the discharge port, part of lubricant oil in the cylinder would be carried by the vapor and atomize into small droplets in the lower cavity during the discharge process, which is complicated and highly-coupled. Some of these oil droplets would ultimately be exhausted from the compressor and enter other parts in the system, reducing the compressor reliability and deteriorating the heat transfer of the condenser and the evaporator in the system. Our previous research studied the atomization of the lubricant oil during the discharge process in the compressor’s lower cavity. However, the oil droplets’ behavior downstream of the lower cavity is unknown. Thus, studying the oil droplets’ behavior after passing through the rotor/stator can help understand how the rotor/stator would affect the droplet size distribution and movement, thus controlling the flow rate of escaped oil droplets. In this study, a hot gas bypass test rig is built to run a modified rotary compressor with sapphire windows right above the rotor/stator. The oil droplets’ size distribution and movement along the radial direction are obtained at the shaft’s rotating frequency of 30 and 60 Hz by shadowgraph. It is found that droplet size at 30 and 60 Hz varies little in the inner region of the rotor/stator clearance and would increase sharply above the clearance and keep increasing in the outer region of the clearance. More importantly, droplet velocity has a downward velocity component at the inner region and an upward velocity component at the outer region of the rotor/stator clearance. With the result of droplet size distribution and droplet velocity above the rotor/stator, we propose the model of the oil droplet’s path above the rotor/stator, which can be understood as the coupling of a swirling jet and a rotating disk.","PeriodicalId":23636,"journal":{"name":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Measurement of Oil Droplets Size and Velocity Above the Rotor/Stator in a Rotary Compressor\",\"authors\":\"Puyuan Wu, Jun Chen, P. Sojka, Yang Li, Hongjun Cao\",\"doi\":\"10.1115/fedsm2021-65874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Hundreds of millions of Air conditioning (AC) systems are produced each year. Many of them, especially small AC appliances, use rotary compressors as the system’s heat pump due to their simple structure and high efficiency in a small system. Lubricant oil is used in the rotary compressor to lubricate the moving parts, such as the crankshaft and the rolling piston, and to seal the clearance between the sliding parts, e.g., the clearance between the rolling piston and the cylinder, and the vane and the cylinder. As the compressed refrigerant vapor is discharged from the cylinder through the discharge port, part of lubricant oil in the cylinder would be carried by the vapor and atomize into small droplets in the lower cavity during the discharge process, which is complicated and highly-coupled. Some of these oil droplets would ultimately be exhausted from the compressor and enter other parts in the system, reducing the compressor reliability and deteriorating the heat transfer of the condenser and the evaporator in the system. Our previous research studied the atomization of the lubricant oil during the discharge process in the compressor’s lower cavity. However, the oil droplets’ behavior downstream of the lower cavity is unknown. Thus, studying the oil droplets’ behavior after passing through the rotor/stator can help understand how the rotor/stator would affect the droplet size distribution and movement, thus controlling the flow rate of escaped oil droplets. In this study, a hot gas bypass test rig is built to run a modified rotary compressor with sapphire windows right above the rotor/stator. The oil droplets’ size distribution and movement along the radial direction are obtained at the shaft’s rotating frequency of 30 and 60 Hz by shadowgraph. It is found that droplet size at 30 and 60 Hz varies little in the inner region of the rotor/stator clearance and would increase sharply above the clearance and keep increasing in the outer region of the clearance. More importantly, droplet velocity has a downward velocity component at the inner region and an upward velocity component at the outer region of the rotor/stator clearance. With the result of droplet size distribution and droplet velocity above the rotor/stator, we propose the model of the oil droplet’s path above the rotor/stator, which can be understood as the coupling of a swirling jet and a rotating disk.\",\"PeriodicalId\":23636,\"journal\":{\"name\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"volume\":\"31 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/fedsm2021-65874\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/fedsm2021-65874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

每年生产数亿台空调(AC)系统。它们中的许多,特别是小型交流电器,使用旋转压缩机作为系统的热泵,因为它们结构简单,在小型系统中效率很高。润滑油在旋转压缩机中用于润滑运动部件,如曲轴和滚动活塞,并密封滑动部件之间的间隙,如滚动活塞与气缸之间的间隙,叶片与气缸之间的间隙。压缩后的制冷剂蒸汽通过排出口从气缸排出,在排出过程中,气缸内的部分润滑油会被蒸汽携带并在下腔内雾化成小液滴,这是一个复杂且高度耦合的过程。其中一些油滴最终会从压缩机中排出并进入系统中的其他部件,从而降低压缩机的可靠性,并恶化系统中冷凝器和蒸发器的传热。我们之前的研究是针对润滑油在压缩机下腔排出过程中的雾化进行的。然而,油滴在下腔下游的行为是未知的。因此,研究油滴通过转子/定子后的行为,有助于了解转子/定子对油滴粒径分布和运动的影响,从而控制油滴的逸出流量。在这项研究中,建立了一个热气体旁路试验台来运行一个改进的旋转压缩机,转子/定子正上方有蓝宝石窗。在轴的旋转频率为30hz和60hz时,用阴影图得到了油滴的尺寸分布和沿径向的运动情况。研究发现,在30和60 Hz时,液滴尺寸在动静间隙内变化不大,在间隙以上急剧增大,在间隙外继续增大。更重要的是,液滴速度在转子/定子间隙内区域有一个向下的速度分量,在转子/定子间隙外区域有一个向上的速度分量。根据液滴在转子/定子上方的尺寸分布和液滴速度,提出了油滴在转子/定子上方的路径模型,该模型可以理解为旋转射流和旋转圆盘的耦合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental Measurement of Oil Droplets Size and Velocity Above the Rotor/Stator in a Rotary Compressor
Hundreds of millions of Air conditioning (AC) systems are produced each year. Many of them, especially small AC appliances, use rotary compressors as the system’s heat pump due to their simple structure and high efficiency in a small system. Lubricant oil is used in the rotary compressor to lubricate the moving parts, such as the crankshaft and the rolling piston, and to seal the clearance between the sliding parts, e.g., the clearance between the rolling piston and the cylinder, and the vane and the cylinder. As the compressed refrigerant vapor is discharged from the cylinder through the discharge port, part of lubricant oil in the cylinder would be carried by the vapor and atomize into small droplets in the lower cavity during the discharge process, which is complicated and highly-coupled. Some of these oil droplets would ultimately be exhausted from the compressor and enter other parts in the system, reducing the compressor reliability and deteriorating the heat transfer of the condenser and the evaporator in the system. Our previous research studied the atomization of the lubricant oil during the discharge process in the compressor’s lower cavity. However, the oil droplets’ behavior downstream of the lower cavity is unknown. Thus, studying the oil droplets’ behavior after passing through the rotor/stator can help understand how the rotor/stator would affect the droplet size distribution and movement, thus controlling the flow rate of escaped oil droplets. In this study, a hot gas bypass test rig is built to run a modified rotary compressor with sapphire windows right above the rotor/stator. The oil droplets’ size distribution and movement along the radial direction are obtained at the shaft’s rotating frequency of 30 and 60 Hz by shadowgraph. It is found that droplet size at 30 and 60 Hz varies little in the inner region of the rotor/stator clearance and would increase sharply above the clearance and keep increasing in the outer region of the clearance. More importantly, droplet velocity has a downward velocity component at the inner region and an upward velocity component at the outer region of the rotor/stator clearance. With the result of droplet size distribution and droplet velocity above the rotor/stator, we propose the model of the oil droplet’s path above the rotor/stator, which can be understood as the coupling of a swirling jet and a rotating disk.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fluid Dynamics and Contact Stress on Hard Sealing Surface Analysis of LNG Cryogenic Ball Valve 0D Modeling of Fuel Tank for Vapor Generation Impact of Urban Microclimate on Air Conditioning Energy Consumption Using Different Convective Heat Transfer Coefficient Correlations Available in Building Energy Simulation Tools Study on Overall Design of a Vertical Take-Off and Landing Unmanned Aerial Vehicle Powered by Electric Ducted Fans Influence of the Topological Structures of the Nose of High-Speed Maglev Train on Aerodynamic Performances
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1