{"title":"光伏发电并网微电网过流保护分析与设计","authors":"Jaymala D. Pradhan ,&nbsp;Somnath S. Hadpe ,&nbsp;Rakesh G. Shriwastava","doi":"10.1016/j.gltp.2022.03.023","DOIUrl":null,"url":null,"abstract":"<div><p>This paper aimed to demonstrate the reliability of the Over Current protection (OCP) scheme in protecting microgrids with inverter interfaced RES for low voltage distribution networks. To prove this reliability, the PSCAD/EMTDC simulation software was used to conduct simulations for the OCP scheme, while comparing throughout grid-connected mode with and without PV generation, as well as in island mode. The computations are carried out using a model of a CIGRE low voltage distribution system. The OCP average relay tripping time for SLG faults through grid mode without PV has been 0.131 s, &amp; 0.121 s for LLL faults. With regards to PV generators, the average relay tripping time increased to 0.199 s &amp; 0.135 s, including both. This is due to the fault current contributed by PV generation inclusion, which restricts the current seen by the predefined OC relays. The findings revealed that some OC relays failed to trip in island mode causing a loss of coordination and a decrease in fault currents. The system was further tested for different generation levels (15%, 57%, and 81%) in island mode and gave a negligible difference in average tripping time for different generation levels.</p></div>","PeriodicalId":100588,"journal":{"name":"Global Transitions Proceedings","volume":"3 1","pages":"Pages 349-358"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666285X22000292/pdfft?md5=62cd1d590c4e97d34fafbd62240ee9b1&pid=1-s2.0-S2666285X22000292-main.pdf","citationCount":"3","resultStr":"{\"title\":\"Analysis and design of overcurrent protection for grid-connected microgrid with PV generation\",\"authors\":\"Jaymala D. Pradhan ,&nbsp;Somnath S. Hadpe ,&nbsp;Rakesh G. Shriwastava\",\"doi\":\"10.1016/j.gltp.2022.03.023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper aimed to demonstrate the reliability of the Over Current protection (OCP) scheme in protecting microgrids with inverter interfaced RES for low voltage distribution networks. To prove this reliability, the PSCAD/EMTDC simulation software was used to conduct simulations for the OCP scheme, while comparing throughout grid-connected mode with and without PV generation, as well as in island mode. The computations are carried out using a model of a CIGRE low voltage distribution system. The OCP average relay tripping time for SLG faults through grid mode without PV has been 0.131 s, &amp; 0.121 s for LLL faults. With regards to PV generators, the average relay tripping time increased to 0.199 s &amp; 0.135 s, including both. This is due to the fault current contributed by PV generation inclusion, which restricts the current seen by the predefined OC relays. The findings revealed that some OC relays failed to trip in island mode causing a loss of coordination and a decrease in fault currents. The system was further tested for different generation levels (15%, 57%, and 81%) in island mode and gave a negligible difference in average tripping time for different generation levels.</p></div>\",\"PeriodicalId\":100588,\"journal\":{\"name\":\"Global Transitions Proceedings\",\"volume\":\"3 1\",\"pages\":\"Pages 349-358\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666285X22000292/pdfft?md5=62cd1d590c4e97d34fafbd62240ee9b1&pid=1-s2.0-S2666285X22000292-main.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Transitions Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666285X22000292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Transitions Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666285X22000292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文旨在证明过流保护(OCP)方案在保护低压配电网中具有逆变器接口的微电网中的可靠性。为了证明这种可靠性,使用PSCAD/EMTDC仿真软件对OCP方案进行了仿真,同时比较了整个并网模式下有和没有光伏发电以及孤岛模式下的情况。利用CIGRE低压配电系统模型进行了计算。无PV电网模式下SLG故障的OCP平均继电器脱扣时间为0.131 s;LLL故障为0.121 s。光伏发电机组的平均继电器脱扣时间增加到0.199 s &0.135秒,包括两者。这是由于光伏发电产生的故障电流,它限制了预定义的OC继电器看到的电流。研究结果表明,一些OC继电器在孤岛模式下未能跳闸,导致协调损失和故障电流减少。在孤岛模式下,对系统进行了不同发电水平(15%、57%和81%)的进一步测试,不同发电水平的平均跳闸时间差异可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis and design of overcurrent protection for grid-connected microgrid with PV generation

This paper aimed to demonstrate the reliability of the Over Current protection (OCP) scheme in protecting microgrids with inverter interfaced RES for low voltage distribution networks. To prove this reliability, the PSCAD/EMTDC simulation software was used to conduct simulations for the OCP scheme, while comparing throughout grid-connected mode with and without PV generation, as well as in island mode. The computations are carried out using a model of a CIGRE low voltage distribution system. The OCP average relay tripping time for SLG faults through grid mode without PV has been 0.131 s, & 0.121 s for LLL faults. With regards to PV generators, the average relay tripping time increased to 0.199 s & 0.135 s, including both. This is due to the fault current contributed by PV generation inclusion, which restricts the current seen by the predefined OC relays. The findings revealed that some OC relays failed to trip in island mode causing a loss of coordination and a decrease in fault currents. The system was further tested for different generation levels (15%, 57%, and 81%) in island mode and gave a negligible difference in average tripping time for different generation levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Enhanced Energy Efficient Secure Routing Protocol for Mobile Ad-Hoc Network Grid interconnected H-bridge multilevel inverter for renewable power applications using repeating units and level boosting network Power Generation Using Ocean Waves: A Review Development of an Arabic HQAS-based ASAG to consider an ignored knowledge in misspelled multiple words short answers Smartphone assist deep neural network to detect the citrus diseases in Agri-informatics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1