用于过程监控应用的管道中新型集成同轴线到圆柱波导指令耦合器

A. Penirschke, J. Freese, J. Biebel, B. Allenberg, R. Jakoby
{"title":"用于过程监控应用的管道中新型集成同轴线到圆柱波导指令耦合器","authors":"A. Penirschke, J. Freese, J. Biebel, B. Allenberg, R. Jakoby","doi":"10.1109/MWSYM.2005.1516892","DOIUrl":null,"url":null,"abstract":"This paper presents a novel coaxial line to circular cylindrical waveguide directive coupler, using a resonant configuration of two integrated coaxial-fed microstrip patches opposite arranged in a measurement pipeline, this configuration a directivity of more than 4 dB at 5.7 GHz can be achieved without disturbing the cross-section of the pipeline. The insertion loss of the proposed coupler is low and hence about -1 dB of the input signal is transmitted into the desired direction of the circular waveguide which is a gain of 2 dB compared to a conventional E-field probe. Similar to commercial available mass flow meters, two of these couplers, at a distance of 0.4 m in the measurement section, form a mass flow sensor (Penirschke et al., 2004).","PeriodicalId":13133,"journal":{"name":"IEEE MTT-S International Microwave Symposium Digest, 2005.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2005-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Novel integrated coaxial line to cylindrical waveguide directive couplers in pipelines for process monitoring applications\",\"authors\":\"A. Penirschke, J. Freese, J. Biebel, B. Allenberg, R. Jakoby\",\"doi\":\"10.1109/MWSYM.2005.1516892\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel coaxial line to circular cylindrical waveguide directive coupler, using a resonant configuration of two integrated coaxial-fed microstrip patches opposite arranged in a measurement pipeline, this configuration a directivity of more than 4 dB at 5.7 GHz can be achieved without disturbing the cross-section of the pipeline. The insertion loss of the proposed coupler is low and hence about -1 dB of the input signal is transmitted into the desired direction of the circular waveguide which is a gain of 2 dB compared to a conventional E-field probe. Similar to commercial available mass flow meters, two of these couplers, at a distance of 0.4 m in the measurement section, form a mass flow sensor (Penirschke et al., 2004).\",\"PeriodicalId\":13133,\"journal\":{\"name\":\"IEEE MTT-S International Microwave Symposium Digest, 2005.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE MTT-S International Microwave Symposium Digest, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2005.1516892\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE MTT-S International Microwave Symposium Digest, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2005.1516892","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

本文提出了一种新型的同轴-圆柱波导定向耦合器,该耦合器采用两个同轴馈电微带贴片相对放置在测量管道中的谐振结构,该结构在5.7 GHz时可实现大于4 dB的指向性,而不干扰管道的横截面。所提出的耦合器的插入损耗很低,因此大约-1 dB的输入信号被传输到圆波导的期望方向,与传统的电磁场探头相比,这是2 dB的增益。与市售的质量流量计类似,两个耦合器在测量段间隔0.4 m处形成一个质量流量传感器(Penirschke et al., 2004)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel integrated coaxial line to cylindrical waveguide directive couplers in pipelines for process monitoring applications
This paper presents a novel coaxial line to circular cylindrical waveguide directive coupler, using a resonant configuration of two integrated coaxial-fed microstrip patches opposite arranged in a measurement pipeline, this configuration a directivity of more than 4 dB at 5.7 GHz can be achieved without disturbing the cross-section of the pipeline. The insertion loss of the proposed coupler is low and hence about -1 dB of the input signal is transmitted into the desired direction of the circular waveguide which is a gain of 2 dB compared to a conventional E-field probe. Similar to commercial available mass flow meters, two of these couplers, at a distance of 0.4 m in the measurement section, form a mass flow sensor (Penirschke et al., 2004).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of dual-band waveguide transformers A metamorphic GaAs HEMT distributed amplifier with 50 GHz bandwidth and low noise for 40 Gbits/s Session TU4C: New applications of time domain methods Power efficient RF pulse compression through switched resonators Monolithic LTCC SiP transmitter for 60GHz wireless communication terminals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1