活动区膨胀土层上拔力对鼓形井直径的影响

İlyas Özkan
{"title":"活动区膨胀土层上拔力对鼓形井直径的影响","authors":"İlyas Özkan","doi":"10.31590/ejosat.1243090","DOIUrl":null,"url":null,"abstract":"Expansive soils are found in many parts of the world that are especially arid and semi-arid regions. They have caused several damages of lightweight structures for decades. For this reason, a more suitable foundation type should be selected and designed for the lightweight structures built on these soils. For example, the application of belled shaft foundation at expansive soil layer is preferable method in practice. However, one of the worst cases at the design of this foundation is accepted that the swelling of expansive soil placed in active zone. Therefore, this condition should be taken into account at the design process of this foundation. In this study, the diameter of belled shaft was separately determined with respect to some factors such as the diameter of shaft, the depth of active zone, the friction angle between shaft and soil, and the ratio between the undrained cohesion of soil at stable zone and the swelling pressure of expansive soil placed in active zone. In the calculation process, four different shaft diameters that are 0.3 m, 0. 45 m, 0.60 m, and 0.75 m were utilized. Also the depth of active zone that started from 1.5 m to 15 m was specified. To sum up, the optimum shaft diameter was found as 0.45 m.","PeriodicalId":12068,"journal":{"name":"European Journal of Science and Technology","volume":"104 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Diameter of Belled Shafts with respect to Uplift Forces Resulted From Expansive Soil Layer in Active Zone\",\"authors\":\"İlyas Özkan\",\"doi\":\"10.31590/ejosat.1243090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Expansive soils are found in many parts of the world that are especially arid and semi-arid regions. They have caused several damages of lightweight structures for decades. For this reason, a more suitable foundation type should be selected and designed for the lightweight structures built on these soils. For example, the application of belled shaft foundation at expansive soil layer is preferable method in practice. However, one of the worst cases at the design of this foundation is accepted that the swelling of expansive soil placed in active zone. Therefore, this condition should be taken into account at the design process of this foundation. In this study, the diameter of belled shaft was separately determined with respect to some factors such as the diameter of shaft, the depth of active zone, the friction angle between shaft and soil, and the ratio between the undrained cohesion of soil at stable zone and the swelling pressure of expansive soil placed in active zone. In the calculation process, four different shaft diameters that are 0.3 m, 0. 45 m, 0.60 m, and 0.75 m were utilized. Also the depth of active zone that started from 1.5 m to 15 m was specified. To sum up, the optimum shaft diameter was found as 0.45 m.\",\"PeriodicalId\":12068,\"journal\":{\"name\":\"European Journal of Science and Technology\",\"volume\":\"104 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31590/ejosat.1243090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31590/ejosat.1243090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

膨胀土在世界上许多特别干旱和半干旱地区都有发现。几十年来,它们对轻型结构造成了多次破坏。因此,对于在这些土壤上建造的轻型结构,应选择和设计更合适的基础类型。例如,在膨胀土层中应用鼓形井底是较好的加固方法。然而,在这种基础的设计中,最糟糕的情况之一是在活动区内膨胀土的膨胀。因此,在本基础的设计过程中应考虑到这一条件。本研究根据井径、活动区深度、井与土的摩擦角、稳定区土不排水黏聚力与活动区膨胀土膨胀压力之比等因素分别确定了铃形井的直径。在计算过程中,采用0.3 m、0。采用45 m、0.60 m和0.75 m。并规定了从1.5 m到15 m的活动区域深度。综上所述,最佳井筒直径为0.45 m。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of Diameter of Belled Shafts with respect to Uplift Forces Resulted From Expansive Soil Layer in Active Zone
Expansive soils are found in many parts of the world that are especially arid and semi-arid regions. They have caused several damages of lightweight structures for decades. For this reason, a more suitable foundation type should be selected and designed for the lightweight structures built on these soils. For example, the application of belled shaft foundation at expansive soil layer is preferable method in practice. However, one of the worst cases at the design of this foundation is accepted that the swelling of expansive soil placed in active zone. Therefore, this condition should be taken into account at the design process of this foundation. In this study, the diameter of belled shaft was separately determined with respect to some factors such as the diameter of shaft, the depth of active zone, the friction angle between shaft and soil, and the ratio between the undrained cohesion of soil at stable zone and the swelling pressure of expansive soil placed in active zone. In the calculation process, four different shaft diameters that are 0.3 m, 0. 45 m, 0.60 m, and 0.75 m were utilized. Also the depth of active zone that started from 1.5 m to 15 m was specified. To sum up, the optimum shaft diameter was found as 0.45 m.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
İnsansız Hava Araçlarında Dayanıklılık Elektrolif Çekimiyle Üretilen Nanoliflerin İnceliğini Etkileyen Parametrelerin Taguchi Yöntemi ile Optimizasyonu Öğrenen Organizasyon ve İnovasyon Koçluğu Modeli Kurumsal Çeviklik Yaklaşımı: Bir vaka çalışması Experimental Investigation of Acoustic Forcing on the Combustion Effect of Propane - Methane Mixtures The Effect of Injection Shaped Plastic Lock Mechanism on Mechanical Properties
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1