{"title":"微米精度距离测量与监测的AMCW雷达","authors":"Frida Strombeck, Z. He, H. Zirath","doi":"10.1109/mwsym.2019.8701002","DOIUrl":null,"url":null,"abstract":"An Amplitude Modulated Continuous Wave (AMCW) radar system is proposed that uses both the phase from the envelope and carrier to achieve micrometer accuracy distance measurement. The system has the benefit of using only two frequencies instead of an entire frequency band which is the case with FMCW radars. Many radar systems can therefore be used in a small area without risking interference. An experimental radar setup at 78 GHz is measured and verified to have a measurement error magnitude of less than 10 micrometer. This system is suitable for modern manufacturing and industry.","PeriodicalId":6720,"journal":{"name":"2019 IEEE MTT-S International Microwave Symposium (IMS)","volume":"16 1","pages":"1473-1475"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"AMCW Radar of Micrometer Accuracy Distance Measurement and Monitoring\",\"authors\":\"Frida Strombeck, Z. He, H. Zirath\",\"doi\":\"10.1109/mwsym.2019.8701002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An Amplitude Modulated Continuous Wave (AMCW) radar system is proposed that uses both the phase from the envelope and carrier to achieve micrometer accuracy distance measurement. The system has the benefit of using only two frequencies instead of an entire frequency band which is the case with FMCW radars. Many radar systems can therefore be used in a small area without risking interference. An experimental radar setup at 78 GHz is measured and verified to have a measurement error magnitude of less than 10 micrometer. This system is suitable for modern manufacturing and industry.\",\"PeriodicalId\":6720,\"journal\":{\"name\":\"2019 IEEE MTT-S International Microwave Symposium (IMS)\",\"volume\":\"16 1\",\"pages\":\"1473-1475\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE MTT-S International Microwave Symposium (IMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/mwsym.2019.8701002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE MTT-S International Microwave Symposium (IMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/mwsym.2019.8701002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AMCW Radar of Micrometer Accuracy Distance Measurement and Monitoring
An Amplitude Modulated Continuous Wave (AMCW) radar system is proposed that uses both the phase from the envelope and carrier to achieve micrometer accuracy distance measurement. The system has the benefit of using only two frequencies instead of an entire frequency band which is the case with FMCW radars. Many radar systems can therefore be used in a small area without risking interference. An experimental radar setup at 78 GHz is measured and verified to have a measurement error magnitude of less than 10 micrometer. This system is suitable for modern manufacturing and industry.