{"title":"表征肱骨方向的装置","authors":"Ian T. Mcdougall, B. King, A. Hodgson","doi":"10.1109/IEMBS.1996.646542","DOIUrl":null,"url":null,"abstract":"In cases of shoulder laxity or instability, physicians assess patients' humeral mobility by estimating the ranges of abduction and rotation over which the patient is pain-free. The present approach is quite subjective and shows poor intra- and inter-physician reliability. This paper describes a device we developed to accurately measure humeral orientation. The device does this by utilizing minimum constraint design to impose a consistent and repeatable axis of rotation on the shoulder joint which ensures that data from different patients assessed by different physicians can be reliably compared.","PeriodicalId":20427,"journal":{"name":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"70 1","pages":"2297-2298 vol.5"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A device for characterizing humeral orientation\",\"authors\":\"Ian T. Mcdougall, B. King, A. Hodgson\",\"doi\":\"10.1109/IEMBS.1996.646542\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In cases of shoulder laxity or instability, physicians assess patients' humeral mobility by estimating the ranges of abduction and rotation over which the patient is pain-free. The present approach is quite subjective and shows poor intra- and inter-physician reliability. This paper describes a device we developed to accurately measure humeral orientation. The device does this by utilizing minimum constraint design to impose a consistent and repeatable axis of rotation on the shoulder joint which ensures that data from different patients assessed by different physicians can be reliably compared.\",\"PeriodicalId\":20427,\"journal\":{\"name\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"70 1\",\"pages\":\"2297-2298 vol.5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1996.646542\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1996.646542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In cases of shoulder laxity or instability, physicians assess patients' humeral mobility by estimating the ranges of abduction and rotation over which the patient is pain-free. The present approach is quite subjective and shows poor intra- and inter-physician reliability. This paper describes a device we developed to accurately measure humeral orientation. The device does this by utilizing minimum constraint design to impose a consistent and repeatable axis of rotation on the shoulder joint which ensures that data from different patients assessed by different physicians can be reliably compared.