{"title":"一种新型的全季节空气NO2被动采样系统","authors":"H. Tang, T. Lau, B. Brassard, W. Cool","doi":"10.1002/(SICI)1520-6521(1999)3:6<338::AID-FACT3>3.0.CO;2-U","DOIUrl":null,"url":null,"abstract":"A new all-season passive sampling system for monitoring NO2 in air has been developed. This passive sampling system employs the same approach as the all-season sampling system for monitoring SO2 reported in FACT [Vol. 1(5), 1997] before, but a new collection medium (CHEMIX™) for sampling NO2 has been developed and is used. Compared to the existing collection media used for NO2 passive samplers, such as a triethanolamine (TEA)-coated cellulose fiber filter, CHEMIX™ is less affected by temperature and relative humidity, and has a higher sampling rate. This system has been extensively tested in the lab (temperature from −27 to 20 °C, relative humidity from 4 to 80%, and wind speed from 0.5 to 150 cm/s) and validated in the field in all climates. Comparing measurements obtained with the use of the new passive sampling system with equivalent measurements with the use of a continuous NO2 analyzer yielded an accuracy of greater than 85%. The new NO2 passive sampling system can be used to measure ambient NO2 concentrations ranging from 0.1 to 50 ppb based on a 1-month exposure period. © 1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3: 338–345, 1999","PeriodicalId":12132,"journal":{"name":"Field Analytical Chemistry and Technology","volume":"1 1","pages":"338-345"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":"{\"title\":\"A new all-season passive sampling system for monitoring NO2 in air\",\"authors\":\"H. Tang, T. Lau, B. Brassard, W. Cool\",\"doi\":\"10.1002/(SICI)1520-6521(1999)3:6<338::AID-FACT3>3.0.CO;2-U\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new all-season passive sampling system for monitoring NO2 in air has been developed. This passive sampling system employs the same approach as the all-season sampling system for monitoring SO2 reported in FACT [Vol. 1(5), 1997] before, but a new collection medium (CHEMIX™) for sampling NO2 has been developed and is used. Compared to the existing collection media used for NO2 passive samplers, such as a triethanolamine (TEA)-coated cellulose fiber filter, CHEMIX™ is less affected by temperature and relative humidity, and has a higher sampling rate. This system has been extensively tested in the lab (temperature from −27 to 20 °C, relative humidity from 4 to 80%, and wind speed from 0.5 to 150 cm/s) and validated in the field in all climates. Comparing measurements obtained with the use of the new passive sampling system with equivalent measurements with the use of a continuous NO2 analyzer yielded an accuracy of greater than 85%. The new NO2 passive sampling system can be used to measure ambient NO2 concentrations ranging from 0.1 to 50 ppb based on a 1-month exposure period. © 1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3: 338–345, 1999\",\"PeriodicalId\":12132,\"journal\":{\"name\":\"Field Analytical Chemistry and Technology\",\"volume\":\"1 1\",\"pages\":\"338-345\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"32\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Field Analytical Chemistry and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/(SICI)1520-6521(1999)3:6<338::AID-FACT3>3.0.CO;2-U\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1520-6521(1999)3:6<338::AID-FACT3>3.0.CO;2-U","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32
A new all-season passive sampling system for monitoring NO2 in air
A new all-season passive sampling system for monitoring NO2 in air has been developed. This passive sampling system employs the same approach as the all-season sampling system for monitoring SO2 reported in FACT [Vol. 1(5), 1997] before, but a new collection medium (CHEMIX™) for sampling NO2 has been developed and is used. Compared to the existing collection media used for NO2 passive samplers, such as a triethanolamine (TEA)-coated cellulose fiber filter, CHEMIX™ is less affected by temperature and relative humidity, and has a higher sampling rate. This system has been extensively tested in the lab (temperature from −27 to 20 °C, relative humidity from 4 to 80%, and wind speed from 0.5 to 150 cm/s) and validated in the field in all climates. Comparing measurements obtained with the use of the new passive sampling system with equivalent measurements with the use of a continuous NO2 analyzer yielded an accuracy of greater than 85%. The new NO2 passive sampling system can be used to measure ambient NO2 concentrations ranging from 0.1 to 50 ppb based on a 1-month exposure period. © 1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3: 338–345, 1999