{"title":"电子束错位对连续频率可调回旋管的影响","authors":"T. Song, Wen Wang, Diwei Liu, Shenggang Liu","doi":"10.1109/IRMMW-THz46771.2020.9370461","DOIUrl":null,"url":null,"abstract":"The effect of the electron beam misalignment on the operating frequency, the frequency-tunable range and the beam-wave interaction efficiency for a continuously frequency-tunable gyrotron has been investigated. It is found that the influence of the misaligned electron beam is significant, the electron beam misalignments should be taken into account and avoided in the design and fabrication of a continuously frequency-tunable gyrotron.","PeriodicalId":6746,"journal":{"name":"2020 45th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)","volume":"464 1","pages":"1-1"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of the Electron Beam Misalignments on a Continuously Frequency-Tunable Gyrotron\",\"authors\":\"T. Song, Wen Wang, Diwei Liu, Shenggang Liu\",\"doi\":\"10.1109/IRMMW-THz46771.2020.9370461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of the electron beam misalignment on the operating frequency, the frequency-tunable range and the beam-wave interaction efficiency for a continuously frequency-tunable gyrotron has been investigated. It is found that the influence of the misaligned electron beam is significant, the electron beam misalignments should be taken into account and avoided in the design and fabrication of a continuously frequency-tunable gyrotron.\",\"PeriodicalId\":6746,\"journal\":{\"name\":\"2020 45th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)\",\"volume\":\"464 1\",\"pages\":\"1-1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 45th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRMMW-THz46771.2020.9370461\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 45th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRMMW-THz46771.2020.9370461","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of the Electron Beam Misalignments on a Continuously Frequency-Tunable Gyrotron
The effect of the electron beam misalignment on the operating frequency, the frequency-tunable range and the beam-wave interaction efficiency for a continuously frequency-tunable gyrotron has been investigated. It is found that the influence of the misaligned electron beam is significant, the electron beam misalignments should be taken into account and avoided in the design and fabrication of a continuously frequency-tunable gyrotron.