电力电缆局部放电测量数据评定的信号处理工具

C. Herold, T. Leibfried
{"title":"电力电缆局部放电测量数据评定的信号处理工具","authors":"C. Herold, T. Leibfried","doi":"10.1109/CEIDP.2008.4772766","DOIUrl":null,"url":null,"abstract":"Due to growing and aging power cable grids, there is a rising need for partial discharge (PD) measurement techniques to identify incorrect installed or damaged cable joints or cavities in paper-insulated lead-covered (PILC) cable. While cable manufacturer or high voltage laboratories are able to measure in shielded environments, where noise levels are insignificant, PD detection and location at power cable lines on-the-field are hampered variously by different interferences and noise. The time domain reflectometry (TDR) is a standard technique for the location of PD in power cables. There, pulses traveling along a cable and their reflections are observed. For offline power cable PD measurement methods, where cables under test are disconnected from service, it is essential to determine the delay time between direct and reflected PD pulse to estimate the ignition point (PD site). With the help of algorithms for arrival time estimation, like peak or onset detection, it is possible to gather such delay times in an automated way, assuming a good signal-to-noise-ratio and a sufficiently high sampling frequency. To get rid of noise, modern de-noising techniques, like the wavelet transform, can be used. The Paper is presenting and comparing enhanced signal processing tools for arrival time estimation and de-noising concerning location accuracy, noise sensitivity and robustness for automated cable PD location software.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Signal processing tools for evaluation of Partial Discharge Measurement Data of Power Cables\",\"authors\":\"C. Herold, T. Leibfried\",\"doi\":\"10.1109/CEIDP.2008.4772766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to growing and aging power cable grids, there is a rising need for partial discharge (PD) measurement techniques to identify incorrect installed or damaged cable joints or cavities in paper-insulated lead-covered (PILC) cable. While cable manufacturer or high voltage laboratories are able to measure in shielded environments, where noise levels are insignificant, PD detection and location at power cable lines on-the-field are hampered variously by different interferences and noise. The time domain reflectometry (TDR) is a standard technique for the location of PD in power cables. There, pulses traveling along a cable and their reflections are observed. For offline power cable PD measurement methods, where cables under test are disconnected from service, it is essential to determine the delay time between direct and reflected PD pulse to estimate the ignition point (PD site). With the help of algorithms for arrival time estimation, like peak or onset detection, it is possible to gather such delay times in an automated way, assuming a good signal-to-noise-ratio and a sufficiently high sampling frequency. To get rid of noise, modern de-noising techniques, like the wavelet transform, can be used. The Paper is presenting and comparing enhanced signal processing tools for arrival time estimation and de-noising concerning location accuracy, noise sensitivity and robustness for automated cable PD location software.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772766\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772766","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

由于电力电缆网格的增长和老化,对局部放电(PD)测量技术的需求不断增加,以识别纸绝缘铅包电缆(PILC)中安装错误或损坏的电缆接头或空腔。虽然电缆制造商或高压实验室能够在屏蔽环境中进行测量,噪声水平微不足道,但现场电力电缆线路的PD检测和定位受到各种干扰和噪声的阻碍。时域反射法(TDR)是电力电缆中PD定位的一种标准技术。在那里,沿着电缆传播的脉冲及其反射被观察到。对于离线电力电缆PD测量方法,当被测电缆与服务断开时,必须确定直接和反射PD脉冲之间的延迟时间,以估计着火点(PD位置)。在到达时间估计算法的帮助下,如峰值或开始检测,假设有良好的信噪比和足够高的采样频率,就可以以自动的方式收集这些延迟时间。为了去除噪声,可以使用小波变换等现代降噪技术。本文介绍并比较了自动化电缆PD定位软件的到达时间估计和降噪的增强信号处理工具,涉及定位精度,噪声灵敏度和鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Signal processing tools for evaluation of Partial Discharge Measurement Data of Power Cables
Due to growing and aging power cable grids, there is a rising need for partial discharge (PD) measurement techniques to identify incorrect installed or damaged cable joints or cavities in paper-insulated lead-covered (PILC) cable. While cable manufacturer or high voltage laboratories are able to measure in shielded environments, where noise levels are insignificant, PD detection and location at power cable lines on-the-field are hampered variously by different interferences and noise. The time domain reflectometry (TDR) is a standard technique for the location of PD in power cables. There, pulses traveling along a cable and their reflections are observed. For offline power cable PD measurement methods, where cables under test are disconnected from service, it is essential to determine the delay time between direct and reflected PD pulse to estimate the ignition point (PD site). With the help of algorithms for arrival time estimation, like peak or onset detection, it is possible to gather such delay times in an automated way, assuming a good signal-to-noise-ratio and a sufficiently high sampling frequency. To get rid of noise, modern de-noising techniques, like the wavelet transform, can be used. The Paper is presenting and comparing enhanced signal processing tools for arrival time estimation and de-noising concerning location accuracy, noise sensitivity and robustness for automated cable PD location software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Statistical Analysis of Partial Discharges from Electrical Trees Grown in a Flexible Epoxy Resin Comparison of Dielectric Properties of Low-density Polyethylene/MgO Composites with Different Size Fillers Enhanced Performance of Tree Initiation V-t Characteristics of Epoxy/Clay Nanocomposite in Comparison with Neat Epoxy Resin Time and spatial-resolved spectroscopic measurement system of PD light emission and its application to observation of PDs in SF6 gas The Effect of Acetophenone and alpha-Methylstyrene on the Space Charge Properties of Low Density Polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1