P. Ortega, J. Prat, A. Mànuel, X. Pastor, J. Jaureguízar
{"title":"Biosend,一个自动生物医学采集系统","authors":"P. Ortega, J. Prat, A. Mànuel, X. Pastor, J. Jaureguízar","doi":"10.1109/IEMBS.1996.656818","DOIUrl":null,"url":null,"abstract":"A virtual instrument to acquire automatically biomedical signals is introduced. The system is constituted by two basic blocks: a hardware unit or concentrator that gathers and sends back all the information shown by the several screens connected to the patient, regardless of their trade-mark, through a single channel series digital standard R3-232 or EIA-422 to a distant computer, in such a way that any additional hardware is superfluous. Secondly, a software subsystem installed in a central computer that permits one to capture, visualize and process all the information from a patient, thus, facilitating the control of such patient, also, making it possible to extract data and statistics that are extremely valuable in medical investigation. This software can be run in a PC or Macintosh environment and it has been designed through LABVIEW 3.1 by National Instruments, a graphic programming language used in the development of automated instrumentation systems.","PeriodicalId":20427,"journal":{"name":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"31 1","pages":"3-4 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biosend, an automated biomedical acquisition system\",\"authors\":\"P. Ortega, J. Prat, A. Mànuel, X. Pastor, J. Jaureguízar\",\"doi\":\"10.1109/IEMBS.1996.656818\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A virtual instrument to acquire automatically biomedical signals is introduced. The system is constituted by two basic blocks: a hardware unit or concentrator that gathers and sends back all the information shown by the several screens connected to the patient, regardless of their trade-mark, through a single channel series digital standard R3-232 or EIA-422 to a distant computer, in such a way that any additional hardware is superfluous. Secondly, a software subsystem installed in a central computer that permits one to capture, visualize and process all the information from a patient, thus, facilitating the control of such patient, also, making it possible to extract data and statistics that are extremely valuable in medical investigation. This software can be run in a PC or Macintosh environment and it has been designed through LABVIEW 3.1 by National Instruments, a graphic programming language used in the development of automated instrumentation systems.\",\"PeriodicalId\":20427,\"journal\":{\"name\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"31 1\",\"pages\":\"3-4 vol.1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1996.656818\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1996.656818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Biosend, an automated biomedical acquisition system
A virtual instrument to acquire automatically biomedical signals is introduced. The system is constituted by two basic blocks: a hardware unit or concentrator that gathers and sends back all the information shown by the several screens connected to the patient, regardless of their trade-mark, through a single channel series digital standard R3-232 or EIA-422 to a distant computer, in such a way that any additional hardware is superfluous. Secondly, a software subsystem installed in a central computer that permits one to capture, visualize and process all the information from a patient, thus, facilitating the control of such patient, also, making it possible to extract data and statistics that are extremely valuable in medical investigation. This software can be run in a PC or Macintosh environment and it has been designed through LABVIEW 3.1 by National Instruments, a graphic programming language used in the development of automated instrumentation systems.