Naumi Paramita Putri Monicasari, N. Ratini, I. W. Sudarsana, Ida Bagus Made Suryatika, I. P. Suardana, I. Widagda, A. Gunawan, R. Irhas
{"title":"使用LINAC品牌Electa precision机器对美国医学物理学家协会(AAPM)放射治疗装置中电子束能量变化的百分比深度剂量(PDD)的依从性测试","authors":"Naumi Paramita Putri Monicasari, N. Ratini, I. W. Sudarsana, Ida Bagus Made Suryatika, I. P. Suardana, I. Widagda, A. Gunawan, R. Irhas","doi":"10.9734/ajmah/2023/v21i10897","DOIUrl":null,"url":null,"abstract":"The purpose of the study was to determine the value of PDD against energy variations in the electron beam using the Elekta Precise Brand LINAC aircraft, and to determine the suitability of the PDD value against energy variations in the electron beam with the standards set by AAPM. PDD value data obtained from the results of research using Sun Nuclear Dosimetry Software (SNC Dosimetry). The results of the study will then be compared with the standard Tolerance value set by AAPM of a maximum of 2%. From the deviation value of each 4 MeV energy is 1.1% - 1.8%, 6 MeV energy is 1.1% - 1.6%, and 8 MeV energy is 1.0% - 1.2%, the deviation error at 4, 6, and 8 MeV energy is in accordance with the tolerance limit set by AAPM which is 2%. So that the Elekta Precise LINAC machine at the Radiotherapy Installation of Prof. Ngoerah Denpasar Hospital is feasible to operate to receive patients.","PeriodicalId":49491,"journal":{"name":"Southeast Asian Journal of Tropical Medicine and Public Health","volume":"44 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise against American Association of Physicists in Medicine (AAPM) PDD with Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar\",\"authors\":\"Naumi Paramita Putri Monicasari, N. Ratini, I. W. Sudarsana, Ida Bagus Made Suryatika, I. P. Suardana, I. Widagda, A. Gunawan, R. Irhas\",\"doi\":\"10.9734/ajmah/2023/v21i10897\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of the study was to determine the value of PDD against energy variations in the electron beam using the Elekta Precise Brand LINAC aircraft, and to determine the suitability of the PDD value against energy variations in the electron beam with the standards set by AAPM. PDD value data obtained from the results of research using Sun Nuclear Dosimetry Software (SNC Dosimetry). The results of the study will then be compared with the standard Tolerance value set by AAPM of a maximum of 2%. From the deviation value of each 4 MeV energy is 1.1% - 1.8%, 6 MeV energy is 1.1% - 1.6%, and 8 MeV energy is 1.0% - 1.2%, the deviation error at 4, 6, and 8 MeV energy is in accordance with the tolerance limit set by AAPM which is 2%. So that the Elekta Precise LINAC machine at the Radiotherapy Installation of Prof. Ngoerah Denpasar Hospital is feasible to operate to receive patients.\",\"PeriodicalId\":49491,\"journal\":{\"name\":\"Southeast Asian Journal of Tropical Medicine and Public Health\",\"volume\":\"44 1\",\"pages\":\"\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2023-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Southeast Asian Journal of Tropical Medicine and Public Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.9734/ajmah/2023/v21i10897\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Southeast Asian Journal of Tropical Medicine and Public Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.9734/ajmah/2023/v21i10897","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise against American Association of Physicists in Medicine (AAPM) PDD with Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar
The purpose of the study was to determine the value of PDD against energy variations in the electron beam using the Elekta Precise Brand LINAC aircraft, and to determine the suitability of the PDD value against energy variations in the electron beam with the standards set by AAPM. PDD value data obtained from the results of research using Sun Nuclear Dosimetry Software (SNC Dosimetry). The results of the study will then be compared with the standard Tolerance value set by AAPM of a maximum of 2%. From the deviation value of each 4 MeV energy is 1.1% - 1.8%, 6 MeV energy is 1.1% - 1.6%, and 8 MeV energy is 1.0% - 1.2%, the deviation error at 4, 6, and 8 MeV energy is in accordance with the tolerance limit set by AAPM which is 2%. So that the Elekta Precise LINAC machine at the Radiotherapy Installation of Prof. Ngoerah Denpasar Hospital is feasible to operate to receive patients.
期刊介绍:
The SEAMEO* Regional Tropical Medicine and Public Health Project was established in 1967 to help improve the health and standard of living of the peoples of Southeast Asia by pooling manpower resources of the participating SEAMEO member countries in a cooperative endeavor to develop and upgrade the research and training capabilities of the existing facilities in these countries. By promoting effective regional cooperation among the participating national centers, it is hoped to minimize waste in duplication of programs and activities. In 1992 the Project was renamed the SEAMEO Regional Tropical Medicine and Public Health Network.