{"title":"消费者可穿戴运动追踪器Fitbit能否用于帕金森病?","authors":"K. Abe","doi":"10.4236/apd.2021.102002","DOIUrl":null,"url":null,"abstract":"Consumer-wearable activity trackers have been used for monitoring health-related metrics to estimate steps, distance, physical activity, energy expenditure, and sleep. The purpose of this mini review was to summarize the evidence for validity of the most popular wrist-worn activity tracker (Fitbit) to estimate those health-related metrics in Parkinson disease. We researched full-length English studies in PubMed, Science Direct, Google Scholar, and Scopus, through September, 2021. In total, 27 studies and a textbook description were included in the review. To adapt consumer-wearable activity trackers for evaluating health-related metrics in Parkinson’s disease (PD) patients, there may be some points to be elucidated and conquered. First, measurement accuracy and precision are required. Second, inter-device reliability for measuring steps, distance, and energy expenditure must be considered. Third, wearability: there are some types of device such as wrist-worn, ankle-worn, belt-fixed, and so on. Overall, Fitbit has advantage for these points. This mini review indicates that Fitbit has enough measurement accuracy and precision to estimate health-related metrics of PD patients including amount of step, physical activity energy expenditure, and quality of sleep.","PeriodicalId":7350,"journal":{"name":"Advances in Parkinson's Disease","volume":"52 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Can We Use Consumer-Wearable Activity Tracker Fitbit in Parkinson Disease?\",\"authors\":\"K. Abe\",\"doi\":\"10.4236/apd.2021.102002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Consumer-wearable activity trackers have been used for monitoring health-related metrics to estimate steps, distance, physical activity, energy expenditure, and sleep. The purpose of this mini review was to summarize the evidence for validity of the most popular wrist-worn activity tracker (Fitbit) to estimate those health-related metrics in Parkinson disease. We researched full-length English studies in PubMed, Science Direct, Google Scholar, and Scopus, through September, 2021. In total, 27 studies and a textbook description were included in the review. To adapt consumer-wearable activity trackers for evaluating health-related metrics in Parkinson’s disease (PD) patients, there may be some points to be elucidated and conquered. First, measurement accuracy and precision are required. Second, inter-device reliability for measuring steps, distance, and energy expenditure must be considered. Third, wearability: there are some types of device such as wrist-worn, ankle-worn, belt-fixed, and so on. Overall, Fitbit has advantage for these points. This mini review indicates that Fitbit has enough measurement accuracy and precision to estimate health-related metrics of PD patients including amount of step, physical activity energy expenditure, and quality of sleep.\",\"PeriodicalId\":7350,\"journal\":{\"name\":\"Advances in Parkinson's Disease\",\"volume\":\"52 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Parkinson's Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/apd.2021.102002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Parkinson's Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/apd.2021.102002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Can We Use Consumer-Wearable Activity Tracker Fitbit in Parkinson Disease?
Consumer-wearable activity trackers have been used for monitoring health-related metrics to estimate steps, distance, physical activity, energy expenditure, and sleep. The purpose of this mini review was to summarize the evidence for validity of the most popular wrist-worn activity tracker (Fitbit) to estimate those health-related metrics in Parkinson disease. We researched full-length English studies in PubMed, Science Direct, Google Scholar, and Scopus, through September, 2021. In total, 27 studies and a textbook description were included in the review. To adapt consumer-wearable activity trackers for evaluating health-related metrics in Parkinson’s disease (PD) patients, there may be some points to be elucidated and conquered. First, measurement accuracy and precision are required. Second, inter-device reliability for measuring steps, distance, and energy expenditure must be considered. Third, wearability: there are some types of device such as wrist-worn, ankle-worn, belt-fixed, and so on. Overall, Fitbit has advantage for these points. This mini review indicates that Fitbit has enough measurement accuracy and precision to estimate health-related metrics of PD patients including amount of step, physical activity energy expenditure, and quality of sleep.