面光学相干层析结合荧光技术在陶瓷固定局部义齿材料缺陷研究中的应用

C. Sinescu, M. Negruțiu, M. Rominu, C. Haiduc, E. Petrescu, Marius Leretter, A. Podoleanu
{"title":"面光学相干层析结合荧光技术在陶瓷固定局部义齿材料缺陷研究中的应用","authors":"C. Sinescu, M. Negruțiu, M. Rominu, C. Haiduc, E. Petrescu, Marius Leretter, A. Podoleanu","doi":"10.5281/ZENODO.1082301","DOIUrl":null,"url":null,"abstract":"Optical Coherence Tomography (OCT) combined with the Confocal Microscopy, as a noninvasive method, permits the determinations of materials defects in the ceramic layers depth. For this study 256 anterior and posterior metal and integral ceramic fixed partial dentures were used, made with Empress (Ivoclar), Wollceram and CAD/CAM (Wieland) technology. For each investigate area 350 slices were obtain and a 3D reconstruction was perform from each stuck. The Optical Coherent Tomography, as a noninvasive method, can be used as a control technique in integral ceramic technology, before placing those fixed partial dentures in the oral cavity. The purpose of this study is to evaluate the capability of En face Optical Coherence Tomography (OCT) combined with a fluorescent method in detection and analysis of possible material defects in metalceramic and integral ceramic fixed partial dentures. As a conclusion, it is important to have a non invasive method to investigate fixed partial prostheses before their insertion in the oral cavity in order to satisfy the high stress requirements and the esthetic function.","PeriodicalId":23673,"journal":{"name":"World Academy of Science, Engineering and Technology, International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering","volume":"11 1","pages":"199-203"},"PeriodicalIF":0.0000,"publicationDate":"2009-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"En-Face Optical Coherence Tomography Combined With Fluorescence In Material Defects Investigations For Ceramic Fixed Partial Dentures\",\"authors\":\"C. Sinescu, M. Negruțiu, M. Rominu, C. Haiduc, E. Petrescu, Marius Leretter, A. Podoleanu\",\"doi\":\"10.5281/ZENODO.1082301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optical Coherence Tomography (OCT) combined with the Confocal Microscopy, as a noninvasive method, permits the determinations of materials defects in the ceramic layers depth. For this study 256 anterior and posterior metal and integral ceramic fixed partial dentures were used, made with Empress (Ivoclar), Wollceram and CAD/CAM (Wieland) technology. For each investigate area 350 slices were obtain and a 3D reconstruction was perform from each stuck. The Optical Coherent Tomography, as a noninvasive method, can be used as a control technique in integral ceramic technology, before placing those fixed partial dentures in the oral cavity. The purpose of this study is to evaluate the capability of En face Optical Coherence Tomography (OCT) combined with a fluorescent method in detection and analysis of possible material defects in metalceramic and integral ceramic fixed partial dentures. As a conclusion, it is important to have a non invasive method to investigate fixed partial prostheses before their insertion in the oral cavity in order to satisfy the high stress requirements and the esthetic function.\",\"PeriodicalId\":23673,\"journal\":{\"name\":\"World Academy of Science, Engineering and Technology, International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering\",\"volume\":\"11 1\",\"pages\":\"199-203\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Academy of Science, Engineering and Technology, International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5281/ZENODO.1082301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Academy of Science, Engineering and Technology, International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5281/ZENODO.1082301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

光学相干层析成像(OCT)与共聚焦显微镜相结合,作为一种非侵入性的方法,可以确定陶瓷层深度中的材料缺陷。本研究采用皇后(Ivoclar)、Wollceram和CAD/CAM (Wieland)技术制作的256个前后侧金属和整体陶瓷固定义齿。对于每个研究区域,获得350片切片,并对每个卡进行三维重建。光学相干断层扫描作为一种非侵入性的方法,可以作为整体陶瓷技术的控制技术,在口腔内放置固定局部义齿之前。本研究的目的是评估En face Optical Coherence Tomography (OCT)结合荧光方法检测和分析金属陶瓷和整体陶瓷固定局部义齿可能存在的材料缺陷的能力。因此,为了满足高应力要求和美观功能,在固定部分假体置入口腔前采用无创方法对其进行检查是非常重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
En-Face Optical Coherence Tomography Combined With Fluorescence In Material Defects Investigations For Ceramic Fixed Partial Dentures
Optical Coherence Tomography (OCT) combined with the Confocal Microscopy, as a noninvasive method, permits the determinations of materials defects in the ceramic layers depth. For this study 256 anterior and posterior metal and integral ceramic fixed partial dentures were used, made with Empress (Ivoclar), Wollceram and CAD/CAM (Wieland) technology. For each investigate area 350 slices were obtain and a 3D reconstruction was perform from each stuck. The Optical Coherent Tomography, as a noninvasive method, can be used as a control technique in integral ceramic technology, before placing those fixed partial dentures in the oral cavity. The purpose of this study is to evaluate the capability of En face Optical Coherence Tomography (OCT) combined with a fluorescent method in detection and analysis of possible material defects in metalceramic and integral ceramic fixed partial dentures. As a conclusion, it is important to have a non invasive method to investigate fixed partial prostheses before their insertion in the oral cavity in order to satisfy the high stress requirements and the esthetic function.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Role and Importance of Genome Sequencing in Prediction of Cancer Risk The Effect of Strength Training and Consumption of Glutamine Supplement on GH/IGF1 Axis Thermography Evaluation on Facial Temperature Recovery after Elastic Gum Bone Mineral Density and Quality, Body Composition of Women in the Postmenopausal Period Bronchospasm Analysis Following the Implementation of a Program of Maximum Aerobic Exercise in Active Men
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1