abo血型不相容肾移植在高度敏感的受者使用死者供者:一个病例报告和文献综述

Lan Zhu, H. Feng, Lu Wang, Zhiliang Guo, Juan Wang, Liang Huang, Hui Guo, Gang Chen
{"title":"abo血型不相容肾移植在高度敏感的受者使用死者供者:一个病例报告和文献综述","authors":"Lan Zhu, H. Feng, Lu Wang, Zhiliang Guo, Juan Wang, Liang Huang, Hui Guo, Gang Chen","doi":"10.3760/CMA.J.ISSN.0254-1785.2019.02.005","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the feasibility and safety of kidney transplantation in highly sensitized recipients by using ABO incompatible (ABOi) and yet human leucocyte antigen (HLA) supremely matched deceased donor kidneys and summarize the literatures as well. \n \n \nMethods \nA kidney graft from a deceased donor of blood type B was transplanted to a highly presensitized recipient of blood type O to achieve a HLA matching number of 7/8 in May 2018. Donor specific antibody (DSA) against HLA was negative and baseline anti-B IgM 1∶16. Plasmapheresis (PP) plus intravenous immunoglobulin (IVIG) plus anti-CD20 antibodies were offered on operation day. Clinical data was retrospectively analyzed. \n \n \nResults \nRenal graft functioned immediately and achieved a normal level of serum creatinine (SCr) at d2 after transplantation. However, the value of SCr increased to 131 μmol/l at d9 with a simultaneously elevated level of anti-B IgM from 1∶2 at d7 to 1∶16. A renal graft biopsy at d11 showed mild inflammation in peritubular capillaries and focal tubulitis with minimal interstitial infiltration. No de novo DSA was detected. Then PP plus IVIG were then given twice, followed by an administration of IVIG alone for another 2 days (20 g/d). After treatments, SCr had a range of 120-140 μmol/l and anti-B IgM level decreased to 1∶4 at d21 post-transplantation. During a follow-up of 6 months, there was no onset of proteinuria or infection and the last value of SCr was 114 μmol/L. \n \n \nConclusions \nIn HLA highly sensitized recipients awaiting for transplant opportunities, successful prevention of HLA antibodies-mediated rejection may be achieved by using ABO incompatible and yet HLA compatible deceased donors. \n \n \nKey words: \nKidney transplantation; Sensitization; ABO incompatible; HLA; Donor specific antibodies","PeriodicalId":9885,"journal":{"name":"Chineae Journal of Organ Transplantation","volume":"36 1","pages":"83-87"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ABO-incompatible kidney transplantation in highly presensitized recipients using deceased donors: a case report and literature review\",\"authors\":\"Lan Zhu, H. Feng, Lu Wang, Zhiliang Guo, Juan Wang, Liang Huang, Hui Guo, Gang Chen\",\"doi\":\"10.3760/CMA.J.ISSN.0254-1785.2019.02.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo explore the feasibility and safety of kidney transplantation in highly sensitized recipients by using ABO incompatible (ABOi) and yet human leucocyte antigen (HLA) supremely matched deceased donor kidneys and summarize the literatures as well. \\n \\n \\nMethods \\nA kidney graft from a deceased donor of blood type B was transplanted to a highly presensitized recipient of blood type O to achieve a HLA matching number of 7/8 in May 2018. Donor specific antibody (DSA) against HLA was negative and baseline anti-B IgM 1∶16. Plasmapheresis (PP) plus intravenous immunoglobulin (IVIG) plus anti-CD20 antibodies were offered on operation day. Clinical data was retrospectively analyzed. \\n \\n \\nResults \\nRenal graft functioned immediately and achieved a normal level of serum creatinine (SCr) at d2 after transplantation. However, the value of SCr increased to 131 μmol/l at d9 with a simultaneously elevated level of anti-B IgM from 1∶2 at d7 to 1∶16. A renal graft biopsy at d11 showed mild inflammation in peritubular capillaries and focal tubulitis with minimal interstitial infiltration. No de novo DSA was detected. Then PP plus IVIG were then given twice, followed by an administration of IVIG alone for another 2 days (20 g/d). After treatments, SCr had a range of 120-140 μmol/l and anti-B IgM level decreased to 1∶4 at d21 post-transplantation. During a follow-up of 6 months, there was no onset of proteinuria or infection and the last value of SCr was 114 μmol/L. \\n \\n \\nConclusions \\nIn HLA highly sensitized recipients awaiting for transplant opportunities, successful prevention of HLA antibodies-mediated rejection may be achieved by using ABO incompatible and yet HLA compatible deceased donors. \\n \\n \\nKey words: \\nKidney transplantation; Sensitization; ABO incompatible; HLA; Donor specific antibodies\",\"PeriodicalId\":9885,\"journal\":{\"name\":\"Chineae Journal of Organ Transplantation\",\"volume\":\"36 1\",\"pages\":\"83-87\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chineae Journal of Organ Transplantation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.0254-1785.2019.02.005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chineae Journal of Organ Transplantation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0254-1785.2019.02.005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨ABO不相容(ABOi)和人类白细胞抗原(HLA)高度匹配的已故供体肾脏在高度敏感受者肾移植中的可行性和安全性,并对相关文献进行总结。方法2018年5月,将一名已故B型血供者的肾移植给一名高度现敏的O型血供者,达到7/8的HLA匹配数。供体HLA特异性抗体(DSA)阴性,基线抗- b IgM 1∶16。在手术当天给予血浆置换(PP)联合静脉注射免疫球蛋白(IVIG)加抗cd20抗体。回顾性分析临床资料。结果移植肾术后即刻恢复功能,血清肌酐(SCr)达到正常水平。而SCr在d9时升高至131 μmol/l,同时抗- b - IgM水平由d7时的1∶2升高至1∶16。11岁肾移植活检显示小管周围毛细血管轻度炎症,局灶性小管炎伴少量间质浸润。未发现新生DSA。然后给予PP加IVIG 2次,随后单独给予IVIG 2天(20 g/d)。处理后SCr为120 ~ 140 μmol/l,抗b IgM水平在移植后21 d降至1∶4。随访6个月,无蛋白尿和感染发生,SCr末值为114 μmol/L。结论:在等待移植机会的HLA高度敏感受者中,可以通过使用ABO不相容和HLA兼容的已故供者来成功预防HLA抗体介导的排斥反应。关键词:肾移植;敏化;ABO血型不相容;HLA;供体特异性抗体
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ABO-incompatible kidney transplantation in highly presensitized recipients using deceased donors: a case report and literature review
Objective To explore the feasibility and safety of kidney transplantation in highly sensitized recipients by using ABO incompatible (ABOi) and yet human leucocyte antigen (HLA) supremely matched deceased donor kidneys and summarize the literatures as well. Methods A kidney graft from a deceased donor of blood type B was transplanted to a highly presensitized recipient of blood type O to achieve a HLA matching number of 7/8 in May 2018. Donor specific antibody (DSA) against HLA was negative and baseline anti-B IgM 1∶16. Plasmapheresis (PP) plus intravenous immunoglobulin (IVIG) plus anti-CD20 antibodies were offered on operation day. Clinical data was retrospectively analyzed. Results Renal graft functioned immediately and achieved a normal level of serum creatinine (SCr) at d2 after transplantation. However, the value of SCr increased to 131 μmol/l at d9 with a simultaneously elevated level of anti-B IgM from 1∶2 at d7 to 1∶16. A renal graft biopsy at d11 showed mild inflammation in peritubular capillaries and focal tubulitis with minimal interstitial infiltration. No de novo DSA was detected. Then PP plus IVIG were then given twice, followed by an administration of IVIG alone for another 2 days (20 g/d). After treatments, SCr had a range of 120-140 μmol/l and anti-B IgM level decreased to 1∶4 at d21 post-transplantation. During a follow-up of 6 months, there was no onset of proteinuria or infection and the last value of SCr was 114 μmol/L. Conclusions In HLA highly sensitized recipients awaiting for transplant opportunities, successful prevention of HLA antibodies-mediated rejection may be achieved by using ABO incompatible and yet HLA compatible deceased donors. Key words: Kidney transplantation; Sensitization; ABO incompatible; HLA; Donor specific antibodies
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison the Diagnostic Value of Doppler Ultrasonography to Biopsy, in Evaluation of Post-transplant Complications and Kidney Function Overview of global organ donation and transplantation in 2020 Development and prospect of clinical research on lung transplantation in post-COVID-19 era. Risk assessment of organ donation and procurement during COVID-19 epidemic Clinical analysis of 2019 coronavirus disease (COVID-19) on one case with living-related kidney transplantation/ 中华器官移植杂志
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1