{"title":"绝缘子充电对击穿和调理的影响","authors":"J. Wetzer, P. Wouters","doi":"10.1109/14.231551","DOIUrl":null,"url":null,"abstract":"As part of a study on HV design concepts for microwave tubes, a number of different insulator designs have been studied. Analysis of the measured DC current, partial discharge activity and breakdown voltage shows that surface charging of insulators is a key mechanism in the breakdown process and in the conditioning process. Insulator parameters are not only the breakdown voltage, but also the conditioning speed and the sensitivity to gas exposure or charge leakage. In all these respects insulators with a field enhancement at the anode are superior. Field enhancements at the cathode are less harmful if stepped insulator shapes are chosen. Effective conditioning requires at least a limited number of breakdowns. With sufficient conditioning breakdowns, all insulator geometries tested reached a breakdown field exceeding 12 kV/mm. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":"116 1","pages":"681-691"},"PeriodicalIF":0.0000,"publicationDate":"1993-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"28","resultStr":"{\"title\":\"The effect of insulator charging on breakdown and conditioning\",\"authors\":\"J. Wetzer, P. Wouters\",\"doi\":\"10.1109/14.231551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As part of a study on HV design concepts for microwave tubes, a number of different insulator designs have been studied. Analysis of the measured DC current, partial discharge activity and breakdown voltage shows that surface charging of insulators is a key mechanism in the breakdown process and in the conditioning process. Insulator parameters are not only the breakdown voltage, but also the conditioning speed and the sensitivity to gas exposure or charge leakage. In all these respects insulators with a field enhancement at the anode are superior. Field enhancements at the cathode are less harmful if stepped insulator shapes are chosen. Effective conditioning requires at least a limited number of breakdowns. With sufficient conditioning breakdowns, all insulator geometries tested reached a breakdown field exceeding 12 kV/mm. >\",\"PeriodicalId\":13105,\"journal\":{\"name\":\"IEEE Transactions on Electrical Insulation\",\"volume\":\"116 1\",\"pages\":\"681-691\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/14.231551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.231551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The effect of insulator charging on breakdown and conditioning
As part of a study on HV design concepts for microwave tubes, a number of different insulator designs have been studied. Analysis of the measured DC current, partial discharge activity and breakdown voltage shows that surface charging of insulators is a key mechanism in the breakdown process and in the conditioning process. Insulator parameters are not only the breakdown voltage, but also the conditioning speed and the sensitivity to gas exposure or charge leakage. In all these respects insulators with a field enhancement at the anode are superior. Field enhancements at the cathode are less harmful if stepped insulator shapes are chosen. Effective conditioning requires at least a limited number of breakdowns. With sufficient conditioning breakdowns, all insulator geometries tested reached a breakdown field exceeding 12 kV/mm. >