利用早期光束碰撞数据对Belle II光谱仪气凝胶RICH计数器的性能进行评价

M. Yonenaga, I. Adachi, L. Burmistrov, F. Diberder, T. Iijima, S. Iwata, S. Kakimoto, H. Kakuno, G. Karyan, H. Kawai, T. Kawasaki, H. Kindo, H.Kitamura, M. Kobayashi, T. Kohriki, T. Konno, S. Korpar, P. Krivzan, T. Kumita, K. Kuze, Y. Lai, M. Mrvar, G. Nazaryan, S. Nishida, M. Nishimura, K. Ogawa, S. Ogawa, R. Pestotnik, A. Seljak, M. Shoji, T. Sumiyoshi, M. Tabata, S. Tamechika, Y. Yusa, L.vSantelj
{"title":"利用早期光束碰撞数据对Belle II光谱仪气凝胶RICH计数器的性能进行评价","authors":"M. Yonenaga, I. Adachi, L. Burmistrov, F. Diberder, T. Iijima, S. Iwata, S. Kakimoto, H. Kakuno, G. Karyan, H. Kawai, T. Kawasaki, H. Kindo, H.Kitamura, M. Kobayashi, T. Kohriki, T. Konno, S. Korpar, P. Krivzan, T. Kumita, K. Kuze, Y. Lai, M. Mrvar, G. Nazaryan, S. Nishida, M. Nishimura, K. Ogawa, S. Ogawa, R. Pestotnik, A. Seljak, M. Shoji, T. Sumiyoshi, M. Tabata, S. Tamechika, Y. Yusa, L.vSantelj","doi":"10.1093/ptep/ptaa090","DOIUrl":null,"url":null,"abstract":"The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \\, {\\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\\ast +} \\to D^0 \\pi^+ (D^0 \\to K^-\\pi^+)$ were used to determine the $\\pi(K)$ efficiency and the $K(\\pi)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \\pm 0.6 \\, \\%$ at a pion misidentification probability of $10.9 \\pm 0.9 \\, \\%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.","PeriodicalId":8827,"journal":{"name":"arXiv: Instrumentation and Detectors","volume":"88 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Performance evaluation of the aerogel RICH counter for the Belle II spectrometer using early beam collision data\",\"authors\":\"M. Yonenaga, I. Adachi, L. Burmistrov, F. Diberder, T. Iijima, S. Iwata, S. Kakimoto, H. Kakuno, G. Karyan, H. Kawai, T. Kawasaki, H. Kindo, H.Kitamura, M. Kobayashi, T. Kohriki, T. Konno, S. Korpar, P. Krivzan, T. Kumita, K. Kuze, Y. Lai, M. Mrvar, G. Nazaryan, S. Nishida, M. Nishimura, K. Ogawa, S. Ogawa, R. Pestotnik, A. Seljak, M. Shoji, T. Sumiyoshi, M. Tabata, S. Tamechika, Y. Yusa, L.vSantelj\",\"doi\":\"10.1093/ptep/ptaa090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \\\\, {\\\\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\\\\ast +} \\\\to D^0 \\\\pi^+ (D^0 \\\\to K^-\\\\pi^+)$ were used to determine the $\\\\pi(K)$ efficiency and the $K(\\\\pi)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \\\\pm 0.6 \\\\, \\\\%$ at a pion misidentification probability of $10.9 \\\\pm 0.9 \\\\, \\\\%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.\",\"PeriodicalId\":8827,\"journal\":{\"name\":\"arXiv: Instrumentation and Detectors\",\"volume\":\"88 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv: Instrumentation and Detectors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ptep/ptaa090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ptep/ptaa090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

气凝胶环成像切伦科夫(ARICH)计数器作为一个粒子识别装置,在Belle II光谱仪的前端盖区域。它能够通过检测二氧化硅气凝胶辐射体中发出的切伦科夫光子来识别动量高达$4 \,{\rm GeV}/c$的介子和介子。在探测器对准和概率密度函数校准后,我们利用早期光束碰撞数据评估了ARICH计数器的性能。使用$D^{\ast +} \到D^0 \pi^+ (D^0 \到K^-\pi^+)$的事件样本来确定$\pi(K)$的效率和$K(\pi)$的误识别概率。我们发现ARICH计数器能够将介子与介子分离,识别效率为93.5 \pm 0.6 \, \%$,而介子错误识别概率为10.9 \pm 0.9 \, \%$。本文介绍了计数器的识别方法及其早期运行时的性能评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation of the aerogel RICH counter for the Belle II spectrometer using early beam collision data
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\ast +} \to D^0 \pi^+ (D^0 \to K^-\pi^+)$ were used to determine the $\pi(K)$ efficiency and the $K(\pi)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \pm 0.6 \, \%$ at a pion misidentification probability of $10.9 \pm 0.9 \, \%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Self-Compensating Co-Magnetometer vs. Spin-Exchange Relaxation-Free Magnetometer: Sensitivity To Nonmagnetic Spin Couplings Fuel rod classification from Passive Gamma Emission Tomography (PGET) of spent nuclear fuel assemblies Search for double $$\beta $$-decay modes of $$^{64}$$Zn using purified zinc Construction and commissioning of CMS CE prototype silicon modules MeV-scale performance of water-based and pure liquid scintillator detectors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1