{"title":"基于滑模观测器的风力发电系统故障监测方法","authors":"Wenxin Yu, Shaoxian Huang, Dan Jiang","doi":"10.24425/AEE.2020.133922","DOIUrl":null,"url":null,"abstract":": In this paper, a rotor current fault monitoring method is proposed based on a sliding mode observer. Firstly, the state-space model of the Double-Fed Induction Generator (DFIG) is constructed by vector transformation. Meanwhile, the stator voltage orientation vector control method is applied to decouple a stator and rotor currents, so as to obtain the correlation between the stator and rotor current. Furthermore, the mathematical model of stator voltage orientation is obtained. Then a state sliding mode observer (SMO) is established for the output current of the rotor of the DFIG. The stability and reachability of the system in a limited time is proved. Finally, the system state is determined by the residuals of the measured and estimated rotor currents. The simulation results show that the method proposed in this paper can effectively monitor the status: a normal state, voltage drop faults, short-circuit faults between windings, and rotor current sensor faults which have the advantages of fast response, high stability.","PeriodicalId":45464,"journal":{"name":"Archives of Electrical Engineering","volume":"121 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A fault monitoring method for wind power generation system based on sliding mode observer\",\"authors\":\"Wenxin Yu, Shaoxian Huang, Dan Jiang\",\"doi\":\"10.24425/AEE.2020.133922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": In this paper, a rotor current fault monitoring method is proposed based on a sliding mode observer. Firstly, the state-space model of the Double-Fed Induction Generator (DFIG) is constructed by vector transformation. Meanwhile, the stator voltage orientation vector control method is applied to decouple a stator and rotor currents, so as to obtain the correlation between the stator and rotor current. Furthermore, the mathematical model of stator voltage orientation is obtained. Then a state sliding mode observer (SMO) is established for the output current of the rotor of the DFIG. The stability and reachability of the system in a limited time is proved. Finally, the system state is determined by the residuals of the measured and estimated rotor currents. The simulation results show that the method proposed in this paper can effectively monitor the status: a normal state, voltage drop faults, short-circuit faults between windings, and rotor current sensor faults which have the advantages of fast response, high stability.\",\"PeriodicalId\":45464,\"journal\":{\"name\":\"Archives of Electrical Engineering\",\"volume\":\"121 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/AEE.2020.133922\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/AEE.2020.133922","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A fault monitoring method for wind power generation system based on sliding mode observer
: In this paper, a rotor current fault monitoring method is proposed based on a sliding mode observer. Firstly, the state-space model of the Double-Fed Induction Generator (DFIG) is constructed by vector transformation. Meanwhile, the stator voltage orientation vector control method is applied to decouple a stator and rotor currents, so as to obtain the correlation between the stator and rotor current. Furthermore, the mathematical model of stator voltage orientation is obtained. Then a state sliding mode observer (SMO) is established for the output current of the rotor of the DFIG. The stability and reachability of the system in a limited time is proved. Finally, the system state is determined by the residuals of the measured and estimated rotor currents. The simulation results show that the method proposed in this paper can effectively monitor the status: a normal state, voltage drop faults, short-circuit faults between windings, and rotor current sensor faults which have the advantages of fast response, high stability.
期刊介绍:
The journal publishes original papers in the field of electrical engineering which covers, but not limited to, the following scope: - Control - Electrical machines and transformers - Electrical & magnetic fields problems - Electric traction - Electro heat - Fuel cells, micro machines, hybrid vehicles - Nondestructive testing & Nondestructive evaluation - Electrical power engineering - Power electronics