{"title":"牙科用Au50-Ag25-Pd25和Ni88.6-Cr11.4合金的腐蚀行为比较","authors":"Irfan Liaquat, A. Ziya, Athar Ibrahim, Urva Malik, Gao Qilong, Muhammad Danial","doi":"10.5599/jese.1931","DOIUrl":null,"url":null,"abstract":"The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization measurements. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectroscopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks.\ns.","PeriodicalId":15660,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"1 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2023-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative corrosion behavior of Au50-Ag25-Pd25 and Ni88.6-Cr11.4 alloys utilized in dental applications\",\"authors\":\"Irfan Liaquat, A. Ziya, Athar Ibrahim, Urva Malik, Gao Qilong, Muhammad Danial\",\"doi\":\"10.5599/jese.1931\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization measurements. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectroscopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks.\\ns.\",\"PeriodicalId\":15660,\"journal\":{\"name\":\"Journal of Electrochemical Science and Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrochemical Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5599/jese.1931\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.1931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
Comparative corrosion behavior of Au50-Ag25-Pd25 and Ni88.6-Cr11.4 alloys utilized in dental applications
The electrochemical behaviour of alloys (Au50-Ag25-Pd25 and Ni88.6-Cr11.4) was studied in Fusayama's artificial saliva at pH 6.5 and 37 °C by using open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization measurements. Electrochemical impedance spectroscopy results were simulated with an equivalent electrical circuit. After immersion in artificial saliva, surface characterization of samples was done using scanning electron microscopy connected with energy-dispersive spectroscopy. All obtained results revealed that Au50-Ag25-Pd25 alloy is much more resistive than Ni88.6-Cr11.4 and can be recommended for the effective treatment of patients with dental prosthetics that have metal frameworks.
s.