Thi Tuyet Ngan Nguyen, Thi Thu Ha Vu, Van Thanh Dang, Tragiang Nguyen, Thi Hai Yen Pham
{"title":"水环境中苯类抗生素电化学测定用聚谷氨酸传感器的制备","authors":"Thi Tuyet Ngan Nguyen, Thi Thu Ha Vu, Van Thanh Dang, Tragiang Nguyen, Thi Hai Yen Pham","doi":"10.15625/2525-2518/16865","DOIUrl":null,"url":null,"abstract":"In this study, a graphite electrode (GrE) modified with polyglutamic acid was used to determine chloramphenicol (CAP), a phenicol antibiotic, in a water environment using adsorptive stripping linear sweep voltammetry. The pGA modification process involved electropolymerization via cyclic voltammetry, resulting in a significantly enlarged electrochemical active area of the pGA/GrE interface (1.5 times greater than that of the unmodified GrE). The highest CAP signal was obtained on the electrode fabricated by scanning 50 cycles in the potential range of -1.2 V to +2.0 V. The CAP signal recorded on the pGA/GrE electrode was nine times higher than that on the GrE, which was due to the larger electrochemical active area of the pGA/GrE and its good adsorption capacity with CAP. Analysis conditions including the pH of electrolyte and accumulation time, were optimized. Under optimal conditions, the calibration curve was built with two linear regions in the concentration ranges of 0.5-20 µmol L-1 (R2 = 0.987) and 20-100 µmol L-1 (R2 = 0.996), and the detection limit for CAP was 0.28 µmol L-1.","PeriodicalId":23553,"journal":{"name":"Vietnam Journal of Science and Technology","volume":"61 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fabrication of polyglutamic acid-based sensor for electrochemical determination of a phenicol antibiotic in water environment\",\"authors\":\"Thi Tuyet Ngan Nguyen, Thi Thu Ha Vu, Van Thanh Dang, Tragiang Nguyen, Thi Hai Yen Pham\",\"doi\":\"10.15625/2525-2518/16865\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a graphite electrode (GrE) modified with polyglutamic acid was used to determine chloramphenicol (CAP), a phenicol antibiotic, in a water environment using adsorptive stripping linear sweep voltammetry. The pGA modification process involved electropolymerization via cyclic voltammetry, resulting in a significantly enlarged electrochemical active area of the pGA/GrE interface (1.5 times greater than that of the unmodified GrE). The highest CAP signal was obtained on the electrode fabricated by scanning 50 cycles in the potential range of -1.2 V to +2.0 V. The CAP signal recorded on the pGA/GrE electrode was nine times higher than that on the GrE, which was due to the larger electrochemical active area of the pGA/GrE and its good adsorption capacity with CAP. Analysis conditions including the pH of electrolyte and accumulation time, were optimized. Under optimal conditions, the calibration curve was built with two linear regions in the concentration ranges of 0.5-20 µmol L-1 (R2 = 0.987) and 20-100 µmol L-1 (R2 = 0.996), and the detection limit for CAP was 0.28 µmol L-1.\",\"PeriodicalId\":23553,\"journal\":{\"name\":\"Vietnam Journal of Science and Technology\",\"volume\":\"61 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vietnam Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15625/2525-2518/16865\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vietnam Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15625/2525-2518/16865","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fabrication of polyglutamic acid-based sensor for electrochemical determination of a phenicol antibiotic in water environment
In this study, a graphite electrode (GrE) modified with polyglutamic acid was used to determine chloramphenicol (CAP), a phenicol antibiotic, in a water environment using adsorptive stripping linear sweep voltammetry. The pGA modification process involved electropolymerization via cyclic voltammetry, resulting in a significantly enlarged electrochemical active area of the pGA/GrE interface (1.5 times greater than that of the unmodified GrE). The highest CAP signal was obtained on the electrode fabricated by scanning 50 cycles in the potential range of -1.2 V to +2.0 V. The CAP signal recorded on the pGA/GrE electrode was nine times higher than that on the GrE, which was due to the larger electrochemical active area of the pGA/GrE and its good adsorption capacity with CAP. Analysis conditions including the pH of electrolyte and accumulation time, were optimized. Under optimal conditions, the calibration curve was built with two linear regions in the concentration ranges of 0.5-20 µmol L-1 (R2 = 0.987) and 20-100 µmol L-1 (R2 = 0.996), and the detection limit for CAP was 0.28 µmol L-1.