{"title":"新型纯化pv- trobe墙的电、空间加热、甲醛降解和细菌活化性能分析","authors":"L. Niansi, L. Xiaoyong, Y. Bendong","doi":"10.52396/JUST-2020-0018","DOIUrl":null,"url":null,"abstract":"On the one hand, PV-Trombe wall is a combined solar system that meets dual functions of space heating and electricity output, but the utilization on the recovered solar heat by PV-Trombe wall is very limited. On the other hand, thermal catalytic oxidation and thermal sterilization are two advanced air purification technologies and both they have huge application potential with solar heat. Therefore, a novel purified PV-Trombe wall for electricity, space heating, formaldehyde degradation and bacteria inactivation was proposed. Firstly, the system thermal and mass transfer model was established and verified by experimental data. Secondly, the comprehensive performance with the PV coverage ratio of 0 was analyzed. Finally, the effect of PV coverage ratio on the system performance was investigated. Accordingly, the main results were: ① Under PV coverage ratio of 0, the average daily air thermal efficiency and formaldehyde single-pass ratio were 0. 46 and 0. 35, respectively. Meanwhile, the total generated volume of clean air by formaldehyde degradation was 93. 4 m3 . Five kinds of bacteria were fully thermal inactivated for several hours. Accordingly, the total generated volume of clean air were 188. 3, 173. 0, 201. 4, 189. 9 and 200. 2 m3 for E. coli, L. monocytogenes, L. plantarum, S. Senftenberg and S. cerevisiae, respectively. ② The PV coverage ratio played a different role on the system comprehensive performances. For specific performances, the PV coverage ratio only had a positive influence on electrical performance and had negative effect on other performances such as thermal, formaldehyde degradation and bacteria inactivation performances. However, considering the system comprehensive performances, the electrical energy was the additional product and the low PV coverage ratio was suggested. ③ The works could provide possible support to the prevention and control of COVID-19. © 2021, Editorial Department of Journal of University of Science and Technology of China. All rights reserved.","PeriodicalId":17548,"journal":{"name":"中国科学技术大学学报","volume":"7 1","pages":"308-318"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The performance analysis on a novel purified pv-trombe wall for electricity, space heating, formaldehyde degradation and bacteria in activation\",\"authors\":\"L. Niansi, L. Xiaoyong, Y. Bendong\",\"doi\":\"10.52396/JUST-2020-0018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On the one hand, PV-Trombe wall is a combined solar system that meets dual functions of space heating and electricity output, but the utilization on the recovered solar heat by PV-Trombe wall is very limited. On the other hand, thermal catalytic oxidation and thermal sterilization are two advanced air purification technologies and both they have huge application potential with solar heat. Therefore, a novel purified PV-Trombe wall for electricity, space heating, formaldehyde degradation and bacteria inactivation was proposed. Firstly, the system thermal and mass transfer model was established and verified by experimental data. Secondly, the comprehensive performance with the PV coverage ratio of 0 was analyzed. Finally, the effect of PV coverage ratio on the system performance was investigated. Accordingly, the main results were: ① Under PV coverage ratio of 0, the average daily air thermal efficiency and formaldehyde single-pass ratio were 0. 46 and 0. 35, respectively. Meanwhile, the total generated volume of clean air by formaldehyde degradation was 93. 4 m3 . Five kinds of bacteria were fully thermal inactivated for several hours. Accordingly, the total generated volume of clean air were 188. 3, 173. 0, 201. 4, 189. 9 and 200. 2 m3 for E. coli, L. monocytogenes, L. plantarum, S. Senftenberg and S. cerevisiae, respectively. ② The PV coverage ratio played a different role on the system comprehensive performances. For specific performances, the PV coverage ratio only had a positive influence on electrical performance and had negative effect on other performances such as thermal, formaldehyde degradation and bacteria inactivation performances. However, considering the system comprehensive performances, the electrical energy was the additional product and the low PV coverage ratio was suggested. ③ The works could provide possible support to the prevention and control of COVID-19. © 2021, Editorial Department of Journal of University of Science and Technology of China. All rights reserved.\",\"PeriodicalId\":17548,\"journal\":{\"name\":\"中国科学技术大学学报\",\"volume\":\"7 1\",\"pages\":\"308-318\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国科学技术大学学报\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://doi.org/10.52396/JUST-2020-0018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国科学技术大学学报","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.52396/JUST-2020-0018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

一方面,PV-Trombe墙是一种组合式太阳能系统,满足空间采暖和电力输出的双重功能,但PV-Trombe墙对回收太阳能热能的利用非常有限。另一方面,热催化氧化和热灭菌是两种先进的空气净化技术,它们都具有巨大的太阳能应用潜力。因此,提出了一种用于电力、空间加热、甲醛降解和细菌灭活的新型纯化PV-Trombe墙。首先,建立了系统的传热传质模型,并用实验数据进行了验证。其次,分析了PV覆盖率为0时的综合性能。最后,研究了光伏覆盖率对系统性能的影响。结果表明:①在PV覆盖率为0时,平均日空气热效率和甲醛单通率均为0;46和0。分别为35。同时,甲醛降解产生的洁净空气总量为93。4立方米。五种细菌被完全热灭活几个小时。据此,洁净空气的总生成量为188。3, 173。0, 201。4、189。9和200。大肠杆菌、单核增生乳杆菌、植物乳杆菌、Senftenberg乳杆菌和酿酒乳杆菌分别为2 m3。②光伏覆盖率对系统综合性能的影响不同。在具体性能方面,PV覆盖率仅对电性能有积极影响,而对热、甲醛降解和细菌灭活等其他性能有消极影响。但从系统综合性能考虑,电能是附加产品,建议采用低光伏覆盖率。③为新冠肺炎疫情防控提供可能的支持。©2021,中国科学技术大学学报编辑部版权所有。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The performance analysis on a novel purified pv-trombe wall for electricity, space heating, formaldehyde degradation and bacteria in activation
On the one hand, PV-Trombe wall is a combined solar system that meets dual functions of space heating and electricity output, but the utilization on the recovered solar heat by PV-Trombe wall is very limited. On the other hand, thermal catalytic oxidation and thermal sterilization are two advanced air purification technologies and both they have huge application potential with solar heat. Therefore, a novel purified PV-Trombe wall for electricity, space heating, formaldehyde degradation and bacteria inactivation was proposed. Firstly, the system thermal and mass transfer model was established and verified by experimental data. Secondly, the comprehensive performance with the PV coverage ratio of 0 was analyzed. Finally, the effect of PV coverage ratio on the system performance was investigated. Accordingly, the main results were: ① Under PV coverage ratio of 0, the average daily air thermal efficiency and formaldehyde single-pass ratio were 0. 46 and 0. 35, respectively. Meanwhile, the total generated volume of clean air by formaldehyde degradation was 93. 4 m3 . Five kinds of bacteria were fully thermal inactivated for several hours. Accordingly, the total generated volume of clean air were 188. 3, 173. 0, 201. 4, 189. 9 and 200. 2 m3 for E. coli, L. monocytogenes, L. plantarum, S. Senftenberg and S. cerevisiae, respectively. ② The PV coverage ratio played a different role on the system comprehensive performances. For specific performances, the PV coverage ratio only had a positive influence on electrical performance and had negative effect on other performances such as thermal, formaldehyde degradation and bacteria inactivation performances. However, considering the system comprehensive performances, the electrical energy was the additional product and the low PV coverage ratio was suggested. ③ The works could provide possible support to the prevention and control of COVID-19. © 2021, Editorial Department of Journal of University of Science and Technology of China. All rights reserved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中国科学技术大学学报
中国科学技术大学学报 Engineering-Mechanical Engineering
CiteScore
0.40
自引率
0.00%
发文量
5692
期刊介绍:
期刊最新文献
Predicting vapor-liquid equilibria of CO<sub>2</sub>+HFC binary mixtures by the PR EOS combined with a group contribution model Design of novel double-layer wrapped ammonium polyphosphate and its application in aging-resistant and flame retardant crosslinked polyethylene composites Effects of residual stress caused by abrasion on the flexoelectric response of BaTiO<sub>3</sub> ceramics Thermophysical properties of 1D materials: Transient characterization down to atomic level Attention: The impact of media attention on market reaction to corporate violations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1