{"title":"针式GMR传感器估算大腔体中磁流体重量密度","authors":"C. Gooneratne, M. Iwahara, M. Kakikawa, Sotoshi Yamada, A. Kurnicki, S. Mukhopadhyay","doi":"10.1109/ICSENST.2008.4757184","DOIUrl":null,"url":null,"abstract":"During hyperthermia therapy for cancer treatment magnetic fluid is injected into the tumor. Hyperthermia therapy exploits the fact that cancer cells are more sensitive to heat than healthy cells. Generally all parameters except the magnetic fluid weight density are known in the specific heat equation which governs the heat given in hyperthermia therapy to destroy cancer cells. Hence, accurate estimation of magnetic fluid weight density inside the body is critical for successful treatment. A unique needle-type GMR sensor is fabricated for inserting into the body in a low-invasive way. This paper presents analytical analysis and experimental results obtained by estimating magnetic fluid weight density in large cavities by the fabricated needle-type GMR sensor.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"9 1","pages":"642-647"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Magnetic fluid weight density estimation in large cavities by a needle-type GMR sensor\",\"authors\":\"C. Gooneratne, M. Iwahara, M. Kakikawa, Sotoshi Yamada, A. Kurnicki, S. Mukhopadhyay\",\"doi\":\"10.1109/ICSENST.2008.4757184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During hyperthermia therapy for cancer treatment magnetic fluid is injected into the tumor. Hyperthermia therapy exploits the fact that cancer cells are more sensitive to heat than healthy cells. Generally all parameters except the magnetic fluid weight density are known in the specific heat equation which governs the heat given in hyperthermia therapy to destroy cancer cells. Hence, accurate estimation of magnetic fluid weight density inside the body is critical for successful treatment. A unique needle-type GMR sensor is fabricated for inserting into the body in a low-invasive way. This paper presents analytical analysis and experimental results obtained by estimating magnetic fluid weight density in large cavities by the fabricated needle-type GMR sensor.\",\"PeriodicalId\":6299,\"journal\":{\"name\":\"2008 3rd International Conference on Sensing Technology\",\"volume\":\"9 1\",\"pages\":\"642-647\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 3rd International Conference on Sensing Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2008.4757184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在癌症治疗的热疗过程中,磁流体被注入肿瘤。热疗疗法利用了癌细胞比健康细胞对热更敏感的事实。一般来说,除磁流体重量密度外,所有参数在比热方程中都是已知的,比热方程控制热疗中破坏癌细胞所给予的热量。因此,准确估计体内磁流体重量密度对成功治疗至关重要。制造了一种独特的针式GMR传感器,以低侵入的方式插入体内。本文介绍了利用制造的针式磁流变传感器对大腔体中磁流体重量密度的分析分析和实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Magnetic fluid weight density estimation in large cavities by a needle-type GMR sensor
During hyperthermia therapy for cancer treatment magnetic fluid is injected into the tumor. Hyperthermia therapy exploits the fact that cancer cells are more sensitive to heat than healthy cells. Generally all parameters except the magnetic fluid weight density are known in the specific heat equation which governs the heat given in hyperthermia therapy to destroy cancer cells. Hence, accurate estimation of magnetic fluid weight density inside the body is critical for successful treatment. A unique needle-type GMR sensor is fabricated for inserting into the body in a low-invasive way. This paper presents analytical analysis and experimental results obtained by estimating magnetic fluid weight density in large cavities by the fabricated needle-type GMR sensor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis and characterization of CuO nanoparticle: Its electrochemical paracetamol sensor activity and substituted-2-aminothiophene synthesis applications Electrochemical-sensor, antimicrobial and Environmental Assessments of Bi 3+ :Mg (1− x) Zr x O 4 NPs synthesized by bio-mediated combustion method CeO2/ZnO nanocomposite-modified glassy carbon electrode as an enhanced sensing platform for sensitive voltammetric determination of norepinephrine Mechanical and corrosion properties of electrochemically deposited Ni-Nb2O5 composite coatings on mild steel for marine Applications Voltammetric analysis of hazardous azo-dye indigo carmine at simple and cost-effective carbon paste sensor modified with L-phenylalanine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1