Domingos Belasco Júnior, Fernando Roberto de Oliveira, José A. N. Serafini, Antônio Carlos da Silva
{"title":"确定与上肢运动的效力-持续时间关系","authors":"Domingos Belasco Júnior, Fernando Roberto de Oliveira, José A. N. Serafini, Antônio Carlos da Silva","doi":"10.1590/S1413-35552010000400008","DOIUrl":null,"url":null,"abstract":"OBJECTIVES: To determine the power-duration relationship in upper limb exercises and to investigate the relationships between parameters derived from this function with physiological indicators of aerobic fitness. METHODS: Ten healthy men (26.2±2.3 years, 75.0±11.8 kg, 178.2±11.5 cm and 15.0±5.7% body fat) performed a ramped test on an arm cycle ergometer with increments of 20 W/min. Subsequently, five tests with constant load were performed until exhaustion, with 70, 80, 90, 95 and 100% difference between VT1 and VO2peak. The critical power (CP) was obtained by means of linearization of the power-duration function. RESULTS: The power-duration relationship was described using an adjusted function (r=0.98±0.02). The VO2 at CP (2.66±0.62 l/min) was higher than VT1 (1.62±0.38 l/min) and VT2 (2.36±0.59 l/min), but lower than VO2peak (3.06±0.62 l/min). The CP workload (103.0±26 W) was significantly different from VT1 (69.5±21 W) and VO2peak workloads (151.0±26.3), but was no different of VT2 (103.5±30.8 W). The association between critical power and aerobic condition indexes were always significant when expressed as VO2 (0.73 to 0.78, p<0.05) and in W (0.83 to 0.91, p<0.05). Determination of CP in upper-limb dynamic exercises is simple and inexpensive, and can be used by physical therapists for prescribing and evaluating upper-limb training programs. CONCLUSIONS: The power-duration relationship in upper-limb exercises can be described by a hyperbolic function and it is associated with physiological indicators of aerobic fitness.","PeriodicalId":21195,"journal":{"name":"Revista Brasileira De Fisioterapia","volume":"37 1","pages":"316-321"},"PeriodicalIF":0.0000,"publicationDate":"2010-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Determinação da relação potência-duração em exercício com membros superiores\",\"authors\":\"Domingos Belasco Júnior, Fernando Roberto de Oliveira, José A. N. Serafini, Antônio Carlos da Silva\",\"doi\":\"10.1590/S1413-35552010000400008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES: To determine the power-duration relationship in upper limb exercises and to investigate the relationships between parameters derived from this function with physiological indicators of aerobic fitness. METHODS: Ten healthy men (26.2±2.3 years, 75.0±11.8 kg, 178.2±11.5 cm and 15.0±5.7% body fat) performed a ramped test on an arm cycle ergometer with increments of 20 W/min. Subsequently, five tests with constant load were performed until exhaustion, with 70, 80, 90, 95 and 100% difference between VT1 and VO2peak. The critical power (CP) was obtained by means of linearization of the power-duration function. RESULTS: The power-duration relationship was described using an adjusted function (r=0.98±0.02). The VO2 at CP (2.66±0.62 l/min) was higher than VT1 (1.62±0.38 l/min) and VT2 (2.36±0.59 l/min), but lower than VO2peak (3.06±0.62 l/min). The CP workload (103.0±26 W) was significantly different from VT1 (69.5±21 W) and VO2peak workloads (151.0±26.3), but was no different of VT2 (103.5±30.8 W). The association between critical power and aerobic condition indexes were always significant when expressed as VO2 (0.73 to 0.78, p<0.05) and in W (0.83 to 0.91, p<0.05). Determination of CP in upper-limb dynamic exercises is simple and inexpensive, and can be used by physical therapists for prescribing and evaluating upper-limb training programs. CONCLUSIONS: The power-duration relationship in upper-limb exercises can be described by a hyperbolic function and it is associated with physiological indicators of aerobic fitness.\",\"PeriodicalId\":21195,\"journal\":{\"name\":\"Revista Brasileira De Fisioterapia\",\"volume\":\"37 1\",\"pages\":\"316-321\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira De Fisioterapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S1413-35552010000400008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Fisioterapia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1413-35552010000400008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determinação da relação potência-duração em exercício com membros superiores
OBJECTIVES: To determine the power-duration relationship in upper limb exercises and to investigate the relationships between parameters derived from this function with physiological indicators of aerobic fitness. METHODS: Ten healthy men (26.2±2.3 years, 75.0±11.8 kg, 178.2±11.5 cm and 15.0±5.7% body fat) performed a ramped test on an arm cycle ergometer with increments of 20 W/min. Subsequently, five tests with constant load were performed until exhaustion, with 70, 80, 90, 95 and 100% difference between VT1 and VO2peak. The critical power (CP) was obtained by means of linearization of the power-duration function. RESULTS: The power-duration relationship was described using an adjusted function (r=0.98±0.02). The VO2 at CP (2.66±0.62 l/min) was higher than VT1 (1.62±0.38 l/min) and VT2 (2.36±0.59 l/min), but lower than VO2peak (3.06±0.62 l/min). The CP workload (103.0±26 W) was significantly different from VT1 (69.5±21 W) and VO2peak workloads (151.0±26.3), but was no different of VT2 (103.5±30.8 W). The association between critical power and aerobic condition indexes were always significant when expressed as VO2 (0.73 to 0.78, p<0.05) and in W (0.83 to 0.91, p<0.05). Determination of CP in upper-limb dynamic exercises is simple and inexpensive, and can be used by physical therapists for prescribing and evaluating upper-limb training programs. CONCLUSIONS: The power-duration relationship in upper-limb exercises can be described by a hyperbolic function and it is associated with physiological indicators of aerobic fitness.