基于级联伽马发射成像仪系统的混合事件MLEM重建方法

Xiao Liu, Hui Liu, Li Cheng, Zheng Gu, R. Yao, Yaqiang Liu
{"title":"基于级联伽马发射成像仪系统的混合事件MLEM重建方法","authors":"Xiao Liu, Hui Liu, Li Cheng, Zheng Gu, R. Yao, Yaqiang Liu","doi":"10.1109/NSS/MIC42677.2020.9507850","DOIUrl":null,"url":null,"abstract":"Many medical radionuclides can emit cascade photons sequentially, yet commercial imaging equipment like PET or SPECT don't make use of this information. We have developed a cascade gamma emission imager system to detect the cascade photons in coincidence for those radionuclide imaging. In previous study, reasonable reconstruction images could be obtained using coincidence event based MLEM (CE-MLEM) but with a low signal-to-noise ratio (SNR), caused by the poor sensitivity of the coincidence event. In this work, we proposed an MLEM with mixed events (ME-MLEM) reconstruction method based on the coincidence events incorporated with the simultaneously detected single photons to improve the SNR while maintaining the spatial resolution. A myocardial phantom filled with 1 mCi 177Lu3+ solution was scanned for 1 hour on our prototype setup. 1.36xl04 coincidence events and 8.27×107 single photons were acquired under a 25.6 ns CTW and 10.8%/14.6% @ 208/113 KeV energy window. CE-MLEM, single photon based MLEM (SP-MLEM), and ME-MLEM with a 0.001 weighting factor between coincidence events and single photons were then used for the image reconstruction. The results showed the potential for ME-MLEM to improve the image SNR while keeping the same spatial resolution as CE-MLEM. Our results demonstrated that our system's image quality could be improved when combined coincidence events and single photons together.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"11 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An MLEM Reconstruction Method with Mixed Events Based on a Cascade Gamma Emission Imager System\",\"authors\":\"Xiao Liu, Hui Liu, Li Cheng, Zheng Gu, R. Yao, Yaqiang Liu\",\"doi\":\"10.1109/NSS/MIC42677.2020.9507850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many medical radionuclides can emit cascade photons sequentially, yet commercial imaging equipment like PET or SPECT don't make use of this information. We have developed a cascade gamma emission imager system to detect the cascade photons in coincidence for those radionuclide imaging. In previous study, reasonable reconstruction images could be obtained using coincidence event based MLEM (CE-MLEM) but with a low signal-to-noise ratio (SNR), caused by the poor sensitivity of the coincidence event. In this work, we proposed an MLEM with mixed events (ME-MLEM) reconstruction method based on the coincidence events incorporated with the simultaneously detected single photons to improve the SNR while maintaining the spatial resolution. A myocardial phantom filled with 1 mCi 177Lu3+ solution was scanned for 1 hour on our prototype setup. 1.36xl04 coincidence events and 8.27×107 single photons were acquired under a 25.6 ns CTW and 10.8%/14.6% @ 208/113 KeV energy window. CE-MLEM, single photon based MLEM (SP-MLEM), and ME-MLEM with a 0.001 weighting factor between coincidence events and single photons were then used for the image reconstruction. The results showed the potential for ME-MLEM to improve the image SNR while keeping the same spatial resolution as CE-MLEM. Our results demonstrated that our system's image quality could be improved when combined coincidence events and single photons together.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"11 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9507850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

许多医用放射性核素可以连续发射级联光子,但商用成像设备,如PET或SPECT,并没有利用这一信息。我们开发了一个级联伽玛发射成像仪系统,用于检测这些放射性核素成像的级联光子的重合。在以往的研究中,使用基于重合事件的MLEM (CE-MLEM)可以获得合理的重建图像,但由于重合事件的灵敏度较差,导致信噪比较低。为了在保持空间分辨率的同时提高信噪比,我们提出了一种基于同时检测到的单光子合并巧合事件的混合事件MLEM (ME-MLEM)重建方法。在我们的原型装置上,对充满1mci 177Lu3+溶液的心肌幻影扫描1小时。在25.6 ns CTW和10.8%/14.6% @ 208/113 KeV能量窗口下,获得了1.36xl04个巧合事件和8.27×107单光子。采用CE-MLEM、基于单光子的MLEM (SP-MLEM)和重合事件与单光子之间权重因子为0.001的ME-MLEM进行图像重建。结果表明,在保持与CE-MLEM相同的空间分辨率的情况下,ME-MLEM具有提高图像信噪比的潜力。结果表明,将偶合事件和单光子结合在一起可以提高系统的成像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An MLEM Reconstruction Method with Mixed Events Based on a Cascade Gamma Emission Imager System
Many medical radionuclides can emit cascade photons sequentially, yet commercial imaging equipment like PET or SPECT don't make use of this information. We have developed a cascade gamma emission imager system to detect the cascade photons in coincidence for those radionuclide imaging. In previous study, reasonable reconstruction images could be obtained using coincidence event based MLEM (CE-MLEM) but with a low signal-to-noise ratio (SNR), caused by the poor sensitivity of the coincidence event. In this work, we proposed an MLEM with mixed events (ME-MLEM) reconstruction method based on the coincidence events incorporated with the simultaneously detected single photons to improve the SNR while maintaining the spatial resolution. A myocardial phantom filled with 1 mCi 177Lu3+ solution was scanned for 1 hour on our prototype setup. 1.36xl04 coincidence events and 8.27×107 single photons were acquired under a 25.6 ns CTW and 10.8%/14.6% @ 208/113 KeV energy window. CE-MLEM, single photon based MLEM (SP-MLEM), and ME-MLEM with a 0.001 weighting factor between coincidence events and single photons were then used for the image reconstruction. The results showed the potential for ME-MLEM to improve the image SNR while keeping the same spatial resolution as CE-MLEM. Our results demonstrated that our system's image quality could be improved when combined coincidence events and single photons together.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1