基于一般放射照相技术的印度尼西亚医疗照射剂量综述

I. B. G. P. Pratama
{"title":"基于一般放射照相技术的印度尼西亚医疗照射剂量综述","authors":"I. B. G. P. Pratama","doi":"10.1063/5.0058876","DOIUrl":null,"url":null,"abstract":"General Radiography is a type of x-ray modality that is used widely for diagnostic purposes in Indonesia. There are three types of imaging systems in General Radiography technology in its development, namely Film, Computed Radiography (CR), and Digital Radiography (DR). In this research, an analysis was made related to comparing the three imaging systems for the Chest PA procedure in Indonesia. Comparing the radiation doses of each technology with the Diagnostic Reference Level in Indonesia (IDRL) has been done. Data collection was carried out using the Si-INTAN application from January 1st, 2019, to December 31st, 2019. The analysis was carried out statistically through a t-test to obtain conclusions about each technology’s different radiation doses. Comparisons with IDRL are based on the value of Q3 (75 percentiles) radiation doses distribution for each technology. The research results showed that CR technology gave the highest dose for the Chest PA examination, which was 0.27 mGy, while DR gave the lowest dose, which was 0.11 mGy. Comparison with IDRL showed that there were doses that exceed IDRL for CR technology, whereas Film and DR technology has no dose data that exceed IDRL. This condition was influenced by an extensive dynamic range on the CR modality that allows overexposure.","PeriodicalId":20561,"journal":{"name":"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)","volume":"87 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Review of medical exposure dose in Indonesia based on general radiography technology\",\"authors\":\"I. B. G. P. Pratama\",\"doi\":\"10.1063/5.0058876\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"General Radiography is a type of x-ray modality that is used widely for diagnostic purposes in Indonesia. There are three types of imaging systems in General Radiography technology in its development, namely Film, Computed Radiography (CR), and Digital Radiography (DR). In this research, an analysis was made related to comparing the three imaging systems for the Chest PA procedure in Indonesia. Comparing the radiation doses of each technology with the Diagnostic Reference Level in Indonesia (IDRL) has been done. Data collection was carried out using the Si-INTAN application from January 1st, 2019, to December 31st, 2019. The analysis was carried out statistically through a t-test to obtain conclusions about each technology’s different radiation doses. Comparisons with IDRL are based on the value of Q3 (75 percentiles) radiation doses distribution for each technology. The research results showed that CR technology gave the highest dose for the Chest PA examination, which was 0.27 mGy, while DR gave the lowest dose, which was 0.11 mGy. Comparison with IDRL showed that there were doses that exceed IDRL for CR technology, whereas Film and DR technology has no dose data that exceed IDRL. This condition was influenced by an extensive dynamic range on the CR modality that allows overexposure.\",\"PeriodicalId\":20561,\"journal\":{\"name\":\"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)\",\"volume\":\"87 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0058876\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0058876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

普通放射照相是一种x射线模式,在印度尼西亚广泛用于诊断目的。一般放射照相技术在其发展过程中有三种成像系统,即胶片、计算机放射照相(CR)和数字放射照相(DR)。在这项研究中,分析了有关比较三种成像系统的胸部PA程序在印度尼西亚。将每种技术的辐射剂量与印度尼西亚的诊断参考水平(IDRL)进行了比较。数据收集于2019年1月1日至2019年12月31日使用Si-INTAN应用程序进行。通过t检验进行统计分析,得出每种技术不同辐射剂量的结论。与IDRL的比较是基于每种技术的Q3(75百分位数)辐射剂量分布值。研究结果显示,CR技术对胸部PA检查的剂量最高,为0.27 mGy, DR最低,为0.11 mGy。与IDRL比较,CR技术有超过IDRL的剂量,而Film和DR技术没有超过IDRL的剂量数据。这种情况受到CR模态上允许过度曝光的广泛动态范围的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Review of medical exposure dose in Indonesia based on general radiography technology
General Radiography is a type of x-ray modality that is used widely for diagnostic purposes in Indonesia. There are three types of imaging systems in General Radiography technology in its development, namely Film, Computed Radiography (CR), and Digital Radiography (DR). In this research, an analysis was made related to comparing the three imaging systems for the Chest PA procedure in Indonesia. Comparing the radiation doses of each technology with the Diagnostic Reference Level in Indonesia (IDRL) has been done. Data collection was carried out using the Si-INTAN application from January 1st, 2019, to December 31st, 2019. The analysis was carried out statistically through a t-test to obtain conclusions about each technology’s different radiation doses. Comparisons with IDRL are based on the value of Q3 (75 percentiles) radiation doses distribution for each technology. The research results showed that CR technology gave the highest dose for the Chest PA examination, which was 0.27 mGy, while DR gave the lowest dose, which was 0.11 mGy. Comparison with IDRL showed that there were doses that exceed IDRL for CR technology, whereas Film and DR technology has no dose data that exceed IDRL. This condition was influenced by an extensive dynamic range on the CR modality that allows overexposure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Singular Integral Operators, Quantitative Flatness, and Boundary Problems Mirzakhani’s Curve Counting and Geodesic Currents The conception of national nuclear emergency preparedness system from the state defense perspective Computer security regulation for nuclear installation: A suggestion Optimal reinsurance combination of quota-share and stop-loss reinsurance based on conditional-tail-expectation (CTE) optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1