Xpert HIV-1病毒载量测定法与罗氏Taqman和雅培M2000 RT在马里巴马科的性能比较

B. Kone, D. Goita, O. Dolo, Daouda Traoré, D. Sogoba, A. Somboro, M. Sanogo, A. Somboro, N. Coulibaly, Alou Sanogo, Z. Diarra, M. Traoré, A. Maiga, B. Baya, Y. Sarro, B. Diarra, A. Koné, D. Diallo, D. Dabitao, J. Holl, M. Belson, S. Dao, R. Murphy, M. Diakité, S. Diallo, S. Doumbia, M. Maiga
{"title":"Xpert HIV-1病毒载量测定法与罗氏Taqman和雅培M2000 RT在马里巴马科的性能比较","authors":"B. Kone, D. Goita, O. Dolo, Daouda Traoré, D. Sogoba, A. Somboro, M. Sanogo, A. Somboro, N. Coulibaly, Alou Sanogo, Z. Diarra, M. Traoré, A. Maiga, B. Baya, Y. Sarro, B. Diarra, A. Koné, D. Diallo, D. Dabitao, J. Holl, M. Belson, S. Dao, R. Murphy, M. Diakité, S. Diallo, S. Doumbia, M. Maiga","doi":"10.37421/JAR.2020.11.815","DOIUrl":null,"url":null,"abstract":"Background: Routine monitoring of HIV-1 Viral Load (VL) is important in patients on Antiretroviral Therapy (ART) management. Access to HIV VL remains a challenge in resource-limited settings, especially in rural areas. Universal access to VL requires more simplified and less restrictive alternatives to current conventional VL methods. The objective of this study was to evaluate the performance of the new rapid (2-hour turnaround time) Xpert HIV-1VL technique compared to Roche TaqMan and Abbott RT m2000 for HIV-1 RNA quantification in HIV- infected patients. Study design: We conducted a cross-sectional study in patients seen for routine VL monitoring between August and November 2018 in a HIV care site in Bamako. The performance of the Xpert HIV-1 VL assay was evaluated against the Roche TaqMan assay and Abbott m2000 RT assay. Performance, utility and reliability/reproducibility were verified using accuracy, sensitivity, specificity, positive and negative predictive values, Diagnostic Odds Ratio (DOR), Kappa coefficient, Pearson correlation coefficient, and Bland-Altman analysis. Results: The Xpert assay compared well with the two current referral assays (Roche TaqMan and Abbott m2000 RT assays). Compared to Roche TaqMan assay the sensitivity was 93.10%, specificity (97.01%) and accuracy (95.20%), the correlation coefficient of Pearson (r) was 0.98 (p <0.01). Bland-Altman analysis showed a mean difference of 0.18 log10 cp/mL; (Standard Deviation) SD=0.33. Compared to the Abbott m2000 RT, the sensitivity, the specificity and the accuracy were respectively 93.44%; 92% and 92.65%. The Xpert HIV-1 VL assay showed a good correlation with a correlation coefficient of Pearson, r=0.99 (p <0.001). The overall mean difference in the HIV-1 VL values obtained by Xpert HIV-1 VL and Abbott m2000 RT assays was 0.08 log10 cp/mL; SD=0.30. Conclusion: Xpert HIV-1 VL showed a good performance compared to Roche TaqMan and Abbott m2000 RT. With the rapid test results (less than 2 h) and ease of testing individual specimens, the Xpert HIV-1 VL assay could be an effective alternative for HIV VL monitoring in resource-limited settings.","PeriodicalId":89166,"journal":{"name":"Journal of AIDS & clinical research","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance Comparison of Xpert HIV-1 Viral Load Assay and Roche Taqman and Abbott M2000 RT in Bamako, Mali\",\"authors\":\"B. Kone, D. Goita, O. Dolo, Daouda Traoré, D. Sogoba, A. Somboro, M. Sanogo, A. Somboro, N. Coulibaly, Alou Sanogo, Z. Diarra, M. Traoré, A. Maiga, B. Baya, Y. Sarro, B. Diarra, A. Koné, D. Diallo, D. Dabitao, J. Holl, M. Belson, S. Dao, R. Murphy, M. Diakité, S. Diallo, S. Doumbia, M. Maiga\",\"doi\":\"10.37421/JAR.2020.11.815\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Routine monitoring of HIV-1 Viral Load (VL) is important in patients on Antiretroviral Therapy (ART) management. Access to HIV VL remains a challenge in resource-limited settings, especially in rural areas. Universal access to VL requires more simplified and less restrictive alternatives to current conventional VL methods. The objective of this study was to evaluate the performance of the new rapid (2-hour turnaround time) Xpert HIV-1VL technique compared to Roche TaqMan and Abbott RT m2000 for HIV-1 RNA quantification in HIV- infected patients. Study design: We conducted a cross-sectional study in patients seen for routine VL monitoring between August and November 2018 in a HIV care site in Bamako. The performance of the Xpert HIV-1 VL assay was evaluated against the Roche TaqMan assay and Abbott m2000 RT assay. Performance, utility and reliability/reproducibility were verified using accuracy, sensitivity, specificity, positive and negative predictive values, Diagnostic Odds Ratio (DOR), Kappa coefficient, Pearson correlation coefficient, and Bland-Altman analysis. Results: The Xpert assay compared well with the two current referral assays (Roche TaqMan and Abbott m2000 RT assays). Compared to Roche TaqMan assay the sensitivity was 93.10%, specificity (97.01%) and accuracy (95.20%), the correlation coefficient of Pearson (r) was 0.98 (p <0.01). Bland-Altman analysis showed a mean difference of 0.18 log10 cp/mL; (Standard Deviation) SD=0.33. Compared to the Abbott m2000 RT, the sensitivity, the specificity and the accuracy were respectively 93.44%; 92% and 92.65%. The Xpert HIV-1 VL assay showed a good correlation with a correlation coefficient of Pearson, r=0.99 (p <0.001). The overall mean difference in the HIV-1 VL values obtained by Xpert HIV-1 VL and Abbott m2000 RT assays was 0.08 log10 cp/mL; SD=0.30. Conclusion: Xpert HIV-1 VL showed a good performance compared to Roche TaqMan and Abbott m2000 RT. With the rapid test results (less than 2 h) and ease of testing individual specimens, the Xpert HIV-1 VL assay could be an effective alternative for HIV VL monitoring in resource-limited settings.\",\"PeriodicalId\":89166,\"journal\":{\"name\":\"Journal of AIDS & clinical research\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of AIDS & clinical research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37421/JAR.2020.11.815\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AIDS & clinical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37421/JAR.2020.11.815","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:常规监测HIV-1病毒载量(VL)对接受抗逆转录病毒治疗(ART)的患者非常重要。在资源有限的环境中,特别是在农村地区,获得艾滋病毒VL仍然是一项挑战。对VL的普遍访问需要对当前传统的VL方法进行更简化和限制更少的替代。本研究的目的是评估新的快速(2小时周转时间)Xpert HIV- 1vl技术与罗氏TaqMan和雅培RT m2000在HIV感染患者中用于HIV-1 RNA定量的性能。研究设计:我们对2018年8月至11月在巴马科的一个艾滋病毒护理点接受常规VL监测的患者进行了一项横断面研究。Xpert HIV-1 VL检测的性能与罗氏TaqMan检测和雅培m2000 RT检测进行比较。使用准确性、敏感性、特异性、阳性和阴性预测值、诊断优势比(DOR)、Kappa系数、Pearson相关系数和Bland-Altman分析验证性能、效用和可靠性/可重复性。结果:与目前推荐的两种检测方法(罗氏TaqMan和雅培m2000 RT检测)相比,Xpert检测效果良好。与Roche TaqMan法比较,灵敏度为93.10%,特异度为97.01%,准确度为95.20%,Pearson相关系数(r)为0.98 (p <0.01)。Bland-Altman分析显示平均差异为0.18 log10 cp/mL;(标准差)SD=0.33。与Abbott m2000 RT相比,其敏感性、特异性和准确性分别为93.44%;92%和92.65%。Xpert HIV-1 VL检测具有良好的相关性,Pearson相关系数r=0.99 (p <0.001)。Xpert HIV-1 VL和Abbott m2000 RT测定获得的HIV-1 VL值的总体平均差异为0.08 log10 cp/mL;SD = 0.30。结论:与罗氏TaqMan和雅培m2000 rt相比,Xpert HIV-1 VL具有较好的检测效果。Xpert HIV-1 VL检测结果快速(不到2小时),且易于检测单个标本,可作为资源有限地区HIV-1 VL监测的有效替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance Comparison of Xpert HIV-1 Viral Load Assay and Roche Taqman and Abbott M2000 RT in Bamako, Mali
Background: Routine monitoring of HIV-1 Viral Load (VL) is important in patients on Antiretroviral Therapy (ART) management. Access to HIV VL remains a challenge in resource-limited settings, especially in rural areas. Universal access to VL requires more simplified and less restrictive alternatives to current conventional VL methods. The objective of this study was to evaluate the performance of the new rapid (2-hour turnaround time) Xpert HIV-1VL technique compared to Roche TaqMan and Abbott RT m2000 for HIV-1 RNA quantification in HIV- infected patients. Study design: We conducted a cross-sectional study in patients seen for routine VL monitoring between August and November 2018 in a HIV care site in Bamako. The performance of the Xpert HIV-1 VL assay was evaluated against the Roche TaqMan assay and Abbott m2000 RT assay. Performance, utility and reliability/reproducibility were verified using accuracy, sensitivity, specificity, positive and negative predictive values, Diagnostic Odds Ratio (DOR), Kappa coefficient, Pearson correlation coefficient, and Bland-Altman analysis. Results: The Xpert assay compared well with the two current referral assays (Roche TaqMan and Abbott m2000 RT assays). Compared to Roche TaqMan assay the sensitivity was 93.10%, specificity (97.01%) and accuracy (95.20%), the correlation coefficient of Pearson (r) was 0.98 (p <0.01). Bland-Altman analysis showed a mean difference of 0.18 log10 cp/mL; (Standard Deviation) SD=0.33. Compared to the Abbott m2000 RT, the sensitivity, the specificity and the accuracy were respectively 93.44%; 92% and 92.65%. The Xpert HIV-1 VL assay showed a good correlation with a correlation coefficient of Pearson, r=0.99 (p <0.001). The overall mean difference in the HIV-1 VL values obtained by Xpert HIV-1 VL and Abbott m2000 RT assays was 0.08 log10 cp/mL; SD=0.30. Conclusion: Xpert HIV-1 VL showed a good performance compared to Roche TaqMan and Abbott m2000 RT. With the rapid test results (less than 2 h) and ease of testing individual specimens, the Xpert HIV-1 VL assay could be an effective alternative for HIV VL monitoring in resource-limited settings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Needle Stick Injury by Aqueous Humor of a 31 Year Old PCR-Positive HIV Patient, a Case Report Molecular Docking-Based Screening for Novel Inhibitors of the Human Immunodeficiency Virus Type 1 Protease that Effectively Reduce the Viral Replication in Human Cells. Statistical Modeling of Survival of Tuberculosis Infected HIV Patients Treated with Antiretroviral Treatment: A Case of Felege Hiwot Referral Hospital, Bahir Dar, Ethiopia Antiretroviral Therapy for the Treatment of HIV Editorial Note for the Journal of AIDS and Clinical Research
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1