{"title":"公寓火灾生命安全技术设施评价","authors":"Yemima Sahmura Vividia, Bangun I. R. Harsritanto","doi":"10.14710/MDL.19.1.2019.50-54","DOIUrl":null,"url":null,"abstract":"Vertical occupancy, especially apartments, began to live the face of the city. Not without reason, housing needs continue to increase sharply as the availability of vacant land is increasingly limited. Occupying an apartment becomes a trend and lifestyle for young people. The reason boils down to productivity. The construction of apartments is usually built close to various activity centers, both business, commercial, education, health to entertainment. The improvement of building construction is not supported by the availability of land that is increasingly limited, especially in the city of Jarakta, making the construction of high-rise buildings anticipate this. The construction of multi-story buildings also increases the risk of fire. In 2018, according to him, there were at least 1,078 recorded disaster events throughout 2018. Head of the Jakarta Fire and Rescue Management Agency, Subedjo, said that out of a total of 897 buildings or tall buildings in Jakarta, 280 tall buildings had not yet accomplished the fire protection system (Dinas, 2018).Therefore, this research needs to be done to evaluate the lifesaving facilities and infrastructure in the building. The application of fire safety in buildings can be evaluated regarding to NFPA 101 (2013). Based on NFPA 101A: Guide on Alternative Approaches for Life Safety (2013), there are 12 elements of safety and Regulation of the Minister of Public Works No. 26 / PRT / M / 2008 concerning Technical Requirements of Fire Protection Systems in Building Buildings. The building that became the object of research is one of the buildings in the area of Jakarta mentioned building X and building Y. The variables that are the focus of the research are fire stairs, fire doors, and access roads. Based on the results of the study, the level of reliability of the means of saving lives against fire hazards in building X is equal to 58% and in building Y is 65%.","PeriodicalId":93737,"journal":{"name":"Brain network and modulation","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"EVALUATION OF LIFE SAFETY TECHNICAL FACILITIES FROM FIRE ON APARTEMENT\",\"authors\":\"Yemima Sahmura Vividia, Bangun I. R. Harsritanto\",\"doi\":\"10.14710/MDL.19.1.2019.50-54\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Vertical occupancy, especially apartments, began to live the face of the city. Not without reason, housing needs continue to increase sharply as the availability of vacant land is increasingly limited. Occupying an apartment becomes a trend and lifestyle for young people. The reason boils down to productivity. The construction of apartments is usually built close to various activity centers, both business, commercial, education, health to entertainment. The improvement of building construction is not supported by the availability of land that is increasingly limited, especially in the city of Jarakta, making the construction of high-rise buildings anticipate this. The construction of multi-story buildings also increases the risk of fire. In 2018, according to him, there were at least 1,078 recorded disaster events throughout 2018. Head of the Jakarta Fire and Rescue Management Agency, Subedjo, said that out of a total of 897 buildings or tall buildings in Jakarta, 280 tall buildings had not yet accomplished the fire protection system (Dinas, 2018).Therefore, this research needs to be done to evaluate the lifesaving facilities and infrastructure in the building. The application of fire safety in buildings can be evaluated regarding to NFPA 101 (2013). Based on NFPA 101A: Guide on Alternative Approaches for Life Safety (2013), there are 12 elements of safety and Regulation of the Minister of Public Works No. 26 / PRT / M / 2008 concerning Technical Requirements of Fire Protection Systems in Building Buildings. The building that became the object of research is one of the buildings in the area of Jakarta mentioned building X and building Y. The variables that are the focus of the research are fire stairs, fire doors, and access roads. Based on the results of the study, the level of reliability of the means of saving lives against fire hazards in building X is equal to 58% and in building Y is 65%.\",\"PeriodicalId\":93737,\"journal\":{\"name\":\"Brain network and modulation\",\"volume\":\"11 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brain network and modulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14710/MDL.19.1.2019.50-54\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain network and modulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/MDL.19.1.2019.50-54","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
垂直居住,尤其是公寓,开始成为城市的面貌。由于可用的空地越来越有限,住房需求继续急剧增加,这并非没有道理。住公寓成为年轻人的一种潮流和生活方式。原因可以归结为生产力。公寓的建设通常建在各种活动中心附近,包括商业、商业、教育、卫生和娱乐。建筑建设的改善没有得到日益有限的土地可用性的支持,特别是在贾拉克塔市,使得高层建筑的建设预计到这一点。多层建筑也增加了火灾的风险。据他介绍,2018年全年至少发生了1078起记录在案的灾难事件。雅加达消防和救援管理局局长Subedjo说,在雅加达总共897座建筑物或高层建筑中,280座高层建筑尚未完成消防系统(Dinas, 2018)。因此,本研究需要对建筑物中的救生设施和基础设施进行评估。消防安全在建筑中的应用可以根据NFPA 101(2013)进行评估。根据NFPA 101A:生命安全替代方法指南(2013),公共工程部长第26 / PRT / M / 2008号关于建筑物消防系统技术要求的安全法规有12个要素。成为研究对象的建筑是雅加达地区提到的X号建筑和y号建筑之一。研究的重点变量是消防楼梯、消防门和通道。根据研究结果,建筑物X对火灾危险的救生手段的可靠性水平等于58%,建筑物Y的可靠性水平等于65%。
EVALUATION OF LIFE SAFETY TECHNICAL FACILITIES FROM FIRE ON APARTEMENT
Vertical occupancy, especially apartments, began to live the face of the city. Not without reason, housing needs continue to increase sharply as the availability of vacant land is increasingly limited. Occupying an apartment becomes a trend and lifestyle for young people. The reason boils down to productivity. The construction of apartments is usually built close to various activity centers, both business, commercial, education, health to entertainment. The improvement of building construction is not supported by the availability of land that is increasingly limited, especially in the city of Jarakta, making the construction of high-rise buildings anticipate this. The construction of multi-story buildings also increases the risk of fire. In 2018, according to him, there were at least 1,078 recorded disaster events throughout 2018. Head of the Jakarta Fire and Rescue Management Agency, Subedjo, said that out of a total of 897 buildings or tall buildings in Jakarta, 280 tall buildings had not yet accomplished the fire protection system (Dinas, 2018).Therefore, this research needs to be done to evaluate the lifesaving facilities and infrastructure in the building. The application of fire safety in buildings can be evaluated regarding to NFPA 101 (2013). Based on NFPA 101A: Guide on Alternative Approaches for Life Safety (2013), there are 12 elements of safety and Regulation of the Minister of Public Works No. 26 / PRT / M / 2008 concerning Technical Requirements of Fire Protection Systems in Building Buildings. The building that became the object of research is one of the buildings in the area of Jakarta mentioned building X and building Y. The variables that are the focus of the research are fire stairs, fire doors, and access roads. Based on the results of the study, the level of reliability of the means of saving lives against fire hazards in building X is equal to 58% and in building Y is 65%.