{"title":"服务交换或大修。燃气轮机应该采用哪种理念","authors":"K. M. Youssef","doi":"10.2118/208221-ms","DOIUrl":null,"url":null,"abstract":"\n Maintenance costs and machine availability are two of the most important concerns to gas turbine equipment owner. Therefore, a well thought out maintenance program that reduces costs while increasing equipment availability should be instituted.\n The correct implementation of planned maintenance relying on preventive maintenance optimization through perfect inspection frequency and scope provides direct benefits in the avoidance of forced outages, unscheduled repairs, and downtime.\n Major overhaul is carried out for each gas turbine every 48,000 firing hours which costs around 1 M USD for each engine and with more than 8 months unavailability for the unit.\n To increase equipment availability and enhance cost and time efficiency, alternatives approaches were evaluated including Service Exchange of gas turbines. It is found that service exchange is the best option for optimizing time and cost of overhaul of such engines.\n This paper is written to improve Major Overhaul practice for existing Gas Turbines from ongoing practice of routine major overhaul including engine strip down, inspection and repair to Service Exchange of Gas Generator and Power Turbine every 48,000 firing hours.","PeriodicalId":10981,"journal":{"name":"Day 4 Thu, November 18, 2021","volume":"47 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Service Exchange or Major Overhaul. Which Philosophy to Implement for Gas Turbine\",\"authors\":\"K. M. Youssef\",\"doi\":\"10.2118/208221-ms\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Maintenance costs and machine availability are two of the most important concerns to gas turbine equipment owner. Therefore, a well thought out maintenance program that reduces costs while increasing equipment availability should be instituted.\\n The correct implementation of planned maintenance relying on preventive maintenance optimization through perfect inspection frequency and scope provides direct benefits in the avoidance of forced outages, unscheduled repairs, and downtime.\\n Major overhaul is carried out for each gas turbine every 48,000 firing hours which costs around 1 M USD for each engine and with more than 8 months unavailability for the unit.\\n To increase equipment availability and enhance cost and time efficiency, alternatives approaches were evaluated including Service Exchange of gas turbines. It is found that service exchange is the best option for optimizing time and cost of overhaul of such engines.\\n This paper is written to improve Major Overhaul practice for existing Gas Turbines from ongoing practice of routine major overhaul including engine strip down, inspection and repair to Service Exchange of Gas Generator and Power Turbine every 48,000 firing hours.\",\"PeriodicalId\":10981,\"journal\":{\"name\":\"Day 4 Thu, November 18, 2021\",\"volume\":\"47 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 4 Thu, November 18, 2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/208221-ms\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 4 Thu, November 18, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/208221-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Service Exchange or Major Overhaul. Which Philosophy to Implement for Gas Turbine
Maintenance costs and machine availability are two of the most important concerns to gas turbine equipment owner. Therefore, a well thought out maintenance program that reduces costs while increasing equipment availability should be instituted.
The correct implementation of planned maintenance relying on preventive maintenance optimization through perfect inspection frequency and scope provides direct benefits in the avoidance of forced outages, unscheduled repairs, and downtime.
Major overhaul is carried out for each gas turbine every 48,000 firing hours which costs around 1 M USD for each engine and with more than 8 months unavailability for the unit.
To increase equipment availability and enhance cost and time efficiency, alternatives approaches were evaluated including Service Exchange of gas turbines. It is found that service exchange is the best option for optimizing time and cost of overhaul of such engines.
This paper is written to improve Major Overhaul practice for existing Gas Turbines from ongoing practice of routine major overhaul including engine strip down, inspection and repair to Service Exchange of Gas Generator and Power Turbine every 48,000 firing hours.