micro-CT评估早期负荷的一体式固定植入体两种不同表面周围的骨密度-一项3个月大的狗的实验研究

IF 1 Q4 ENGINEERING, BIOMEDICAL AIMS Bioengineering Pub Date : 2022-01-01 DOI:10.3934/bioeng.2022028
J. Calvo-Guirado, Nuria García Carrillo, Félix de Carlos-Villafranca, M. Garcés-Villalá, L. Mahesh, J. Ibáñez, F. Martínez-Martínez
{"title":"micro-CT评估早期负荷的一体式固定植入体两种不同表面周围的骨密度-一项3个月大的狗的实验研究","authors":"J. Calvo-Guirado, Nuria García Carrillo, Félix de Carlos-Villafranca, M. Garcés-Villalá, L. Mahesh, J. Ibáñez, F. Martínez-Martínez","doi":"10.3934/bioeng.2022028","DOIUrl":null,"url":null,"abstract":"The study's main objective was to evaluate the bone density and osseointegration around dental implants with two different implant surfaces with early loading, using a micro-CT device. Twenty-four Fixo® implants (Oxyimplant, Biomec Italy) 3.5 × 8.5 mm with Laser (test group) and acid-etched surface (control group) were placed in six young beagle dog's mandibles. MicroCT (Albira, Germay) evaluation with seven regions of interest was defined in each implant on two different surfaces. A total of 168 sites were studied, and four isocountours were also done in each implant at coronal, transversal, and sagittal scanned areas to evaluate bone density location. The effect on the bone evaluation of two different surfaces variables was evaluated at the mesial and distal positions, showing crestal, medial, and apical types of bone density. Implant positions (P2, P3, P4, and M1) were also analyzed to determine bone density areas. The results of hard tissue density indicated a statistical significance for laser surface at crestal ROIs level (p < 0.001) and position of implants (p = 0.032) related to P3 areas compared to the acid-etched surface in Fixo® implants. Density D4 was the most common type of bone surrounding Fixo® standard implants at three different positions and density D3 was the most found on Fixo® laser surfaces. Micro-CT evaluation was a powerful tool for measuring the type of bone quality and location surrounding dental implants. Micro-CT study revealed that the most common density type found around Fixo® laser surface (test) implants was density D3 at the mesial and distal coronal part and density D4 at the middle and apical part. Fixo® implant with acid-etched surface showed the type of density D4 bone in hole implant at 3 months follow-up. It is a complementary histologic and histomorphometric analysis method for implant surrounding bone density.","PeriodicalId":45029,"journal":{"name":"AIMS Bioengineering","volume":"43 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A micro-CT evaluation of bone density around two different types of surfaces on one-piece fixo implants with early loading-an experimental study in dogs at 3 months\",\"authors\":\"J. Calvo-Guirado, Nuria García Carrillo, Félix de Carlos-Villafranca, M. Garcés-Villalá, L. Mahesh, J. Ibáñez, F. Martínez-Martínez\",\"doi\":\"10.3934/bioeng.2022028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study's main objective was to evaluate the bone density and osseointegration around dental implants with two different implant surfaces with early loading, using a micro-CT device. Twenty-four Fixo® implants (Oxyimplant, Biomec Italy) 3.5 × 8.5 mm with Laser (test group) and acid-etched surface (control group) were placed in six young beagle dog's mandibles. MicroCT (Albira, Germay) evaluation with seven regions of interest was defined in each implant on two different surfaces. A total of 168 sites were studied, and four isocountours were also done in each implant at coronal, transversal, and sagittal scanned areas to evaluate bone density location. The effect on the bone evaluation of two different surfaces variables was evaluated at the mesial and distal positions, showing crestal, medial, and apical types of bone density. Implant positions (P2, P3, P4, and M1) were also analyzed to determine bone density areas. The results of hard tissue density indicated a statistical significance for laser surface at crestal ROIs level (p < 0.001) and position of implants (p = 0.032) related to P3 areas compared to the acid-etched surface in Fixo® implants. Density D4 was the most common type of bone surrounding Fixo® standard implants at three different positions and density D3 was the most found on Fixo® laser surfaces. Micro-CT evaluation was a powerful tool for measuring the type of bone quality and location surrounding dental implants. Micro-CT study revealed that the most common density type found around Fixo® laser surface (test) implants was density D3 at the mesial and distal coronal part and density D4 at the middle and apical part. Fixo® implant with acid-etched surface showed the type of density D4 bone in hole implant at 3 months follow-up. It is a complementary histologic and histomorphometric analysis method for implant surrounding bone density.\",\"PeriodicalId\":45029,\"journal\":{\"name\":\"AIMS Bioengineering\",\"volume\":\"43 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIMS Bioengineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3934/bioeng.2022028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIMS Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3934/bioeng.2022028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

摘要

该研究的主要目的是利用微型ct设备评估两种不同种植体表面早期加载牙种植体周围的骨密度和骨整合。将24颗Fixo®种植体(Oxyimplant, Biomec Italy) 3.5 × 8.5 mm,激光(试验组)和酸蚀表面(对照组)放置在6只幼年beagle犬的下颌骨上。MicroCT (Albira, germany)在每个种植体的两个不同表面上定义了七个感兴趣的区域。共研究了168个位置,并在每个种植体的冠状、横向和矢状扫描区域进行了4次等面扫描,以评估骨密度位置。在中、远端位置评估两种不同表面变量对骨评估的影响,显示骨密度的嵴、内侧和根尖类型。还分析种植体位置(P2、P3、P4和M1)以确定骨密度面积。硬组织密度结果显示,与Fixo®种植体的酸蚀表面相比,牙冠roi水平激光表面(p < 0.001)和种植体位置与P3区相关(p = 0.032)具有统计学意义。密度D4是Fixo®标准种植体周围三个不同位置最常见的骨类型,密度D3在Fixo®激光表面最常见。显微ct评价是测量种植体周围骨质量和位置的有力工具。Micro-CT研究显示,Fixo®激光表面(测试)种植体周围最常见的密度类型是冠状中、远端D3密度和中、根尖D4密度。Fixo®酸蚀面种植体在随访3个月时显示密度为D4型骨孔种植体。它是种植体周围骨密度的一种补充组织学和组织形态学分析方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A micro-CT evaluation of bone density around two different types of surfaces on one-piece fixo implants with early loading-an experimental study in dogs at 3 months
The study's main objective was to evaluate the bone density and osseointegration around dental implants with two different implant surfaces with early loading, using a micro-CT device. Twenty-four Fixo® implants (Oxyimplant, Biomec Italy) 3.5 × 8.5 mm with Laser (test group) and acid-etched surface (control group) were placed in six young beagle dog's mandibles. MicroCT (Albira, Germay) evaluation with seven regions of interest was defined in each implant on two different surfaces. A total of 168 sites were studied, and four isocountours were also done in each implant at coronal, transversal, and sagittal scanned areas to evaluate bone density location. The effect on the bone evaluation of two different surfaces variables was evaluated at the mesial and distal positions, showing crestal, medial, and apical types of bone density. Implant positions (P2, P3, P4, and M1) were also analyzed to determine bone density areas. The results of hard tissue density indicated a statistical significance for laser surface at crestal ROIs level (p < 0.001) and position of implants (p = 0.032) related to P3 areas compared to the acid-etched surface in Fixo® implants. Density D4 was the most common type of bone surrounding Fixo® standard implants at three different positions and density D3 was the most found on Fixo® laser surfaces. Micro-CT evaluation was a powerful tool for measuring the type of bone quality and location surrounding dental implants. Micro-CT study revealed that the most common density type found around Fixo® laser surface (test) implants was density D3 at the mesial and distal coronal part and density D4 at the middle and apical part. Fixo® implant with acid-etched surface showed the type of density D4 bone in hole implant at 3 months follow-up. It is a complementary histologic and histomorphometric analysis method for implant surrounding bone density.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
AIMS Bioengineering
AIMS Bioengineering ENGINEERING, BIOMEDICAL-
自引率
0.00%
发文量
17
审稿时长
4 weeks
期刊最新文献
Real data-based optimal control strategies for assessing the impact of the Omicron variant on heart attacks Decision support systems in healthcare: systematic review, meta-analysis and prediction, with example of COVID-19 Detection and analysis of coagulation effect in vein using MEMS laminar flow for the early heart stroke diagnosis An insight into the biomaterials used in craniofacial tissue engineering inclusive of regenerative dentistry Identification of diagnostic biomarkers of gestational diabetes mellitus based on transcriptome gene expression and alternations of microRNAs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1