S. Tsuburaya, M. Mizuno, S. Yamada, Takeyoshi Tanaka, T. Wakamatsu, M. Morita, S. Sugahara
{"title":"建筑火灾疏散安全评估动态仿真程序的开发。第三部分:案例分析","authors":"S. Tsuburaya, M. Mizuno, S. Yamada, Takeyoshi Tanaka, T. Wakamatsu, M. Morita, S. Sugahara","doi":"10.3210/FST.26.379","DOIUrl":null,"url":null,"abstract":"In this study (1. limitation of the evacuation route according to the combustion expansion) (2. traffic control by the stay in the evacuation route), the integrated simulation program that purposes evaluate the evacuation safety at a building fire taking it into consideration is developed. The opening and shutting condition etc. of the evacuation action and the door make it link by running parallel to the evacuation action analysis and executing the smoke flow analysis in this simulation. Moreover, to enable the simulation to be used easily, special I/O interface (GUI) was developed. It reported on the outline of the evacuation safety evaluation simulation program at a building fire of development by (1) and (2) of the previous study. In this Part 3, it reports on the case study that uses this program.","PeriodicalId":12289,"journal":{"name":"Fire Science and Technology","volume":"117 1","pages":"379-383"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of the Dynamic Simulation Program for Evaluation of Evacuation Safety in the Building Fire Part 3 Case studies\",\"authors\":\"S. Tsuburaya, M. Mizuno, S. Yamada, Takeyoshi Tanaka, T. Wakamatsu, M. Morita, S. Sugahara\",\"doi\":\"10.3210/FST.26.379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study (1. limitation of the evacuation route according to the combustion expansion) (2. traffic control by the stay in the evacuation route), the integrated simulation program that purposes evaluate the evacuation safety at a building fire taking it into consideration is developed. The opening and shutting condition etc. of the evacuation action and the door make it link by running parallel to the evacuation action analysis and executing the smoke flow analysis in this simulation. Moreover, to enable the simulation to be used easily, special I/O interface (GUI) was developed. It reported on the outline of the evacuation safety evaluation simulation program at a building fire of development by (1) and (2) of the previous study. In this Part 3, it reports on the case study that uses this program.\",\"PeriodicalId\":12289,\"journal\":{\"name\":\"Fire Science and Technology\",\"volume\":\"117 1\",\"pages\":\"379-383\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Science and Technology\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3210/FST.26.379\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Science and Technology","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3210/FST.26.379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of the Dynamic Simulation Program for Evaluation of Evacuation Safety in the Building Fire Part 3 Case studies
In this study (1. limitation of the evacuation route according to the combustion expansion) (2. traffic control by the stay in the evacuation route), the integrated simulation program that purposes evaluate the evacuation safety at a building fire taking it into consideration is developed. The opening and shutting condition etc. of the evacuation action and the door make it link by running parallel to the evacuation action analysis and executing the smoke flow analysis in this simulation. Moreover, to enable the simulation to be used easily, special I/O interface (GUI) was developed. It reported on the outline of the evacuation safety evaluation simulation program at a building fire of development by (1) and (2) of the previous study. In this Part 3, it reports on the case study that uses this program.