求助PDF
{"title":"(电)加热催化剂技术的燃料惩罚比较=电加热催化剂技术增加燃料消耗的比较","authors":"Joseph Kessels, D. L. Foster, W.A.J. Bleuanus","doi":"10.2516/OGST/2009078","DOIUrl":null,"url":null,"abstract":"The conversion efficiency of three way catalytic converters is mainly defined by the temperature range wherein they are operating. Traditionally, ignition retard has been used to reduce the light-off time of the catalyst. This is however associated with a fuel penalty. With increasing vehicle electrification, electrically heating facilities present an alternative, especially for hybrid vehicles. Nevertheless, system complexity of hybrid vehicles prevents engineers to evaluate possible heating technologies and their corresponding fuel penalty with respect to traditional solutions. This paper evaluates the application of an electrically heated catalyst on a hybrid vehicle equipped with a Natural Gas (NG) engine. The effect of heating power on light-off time and fuel penalty is determined, using analysis techniques emerging from integrated powertrain control. By means of a case study, the importance of an integral approach is explained by comparing the fuel penalty and conversion efficiency improvement of electric heating with that of ignition retard. In this process, a mix of simulation and test data were combined, forming the foundations for future control developments of a suitable light-off strategy. © 2010 Institut francais du petrole.","PeriodicalId":19444,"journal":{"name":"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole","volume":"33 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Fuel penalty comparison for (electrically) heated catalyst technology = Comparaison de l’augmentation de consommation de carburant pour la technologie de catalyseurs chauffés à l’électricité\",\"authors\":\"Joseph Kessels, D. L. Foster, W.A.J. Bleuanus\",\"doi\":\"10.2516/OGST/2009078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The conversion efficiency of three way catalytic converters is mainly defined by the temperature range wherein they are operating. Traditionally, ignition retard has been used to reduce the light-off time of the catalyst. This is however associated with a fuel penalty. With increasing vehicle electrification, electrically heating facilities present an alternative, especially for hybrid vehicles. Nevertheless, system complexity of hybrid vehicles prevents engineers to evaluate possible heating technologies and their corresponding fuel penalty with respect to traditional solutions. This paper evaluates the application of an electrically heated catalyst on a hybrid vehicle equipped with a Natural Gas (NG) engine. The effect of heating power on light-off time and fuel penalty is determined, using analysis techniques emerging from integrated powertrain control. By means of a case study, the importance of an integral approach is explained by comparing the fuel penalty and conversion efficiency improvement of electric heating with that of ignition retard. In this process, a mix of simulation and test data were combined, forming the foundations for future control developments of a suitable light-off strategy. © 2010 Institut francais du petrole.\",\"PeriodicalId\":19444,\"journal\":{\"name\":\"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole\",\"volume\":\"33 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2516/OGST/2009078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2516/OGST/2009078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
引用
批量引用
Fuel penalty comparison for (electrically) heated catalyst technology = Comparaison de l’augmentation de consommation de carburant pour la technologie de catalyseurs chauffés à l’électricité
The conversion efficiency of three way catalytic converters is mainly defined by the temperature range wherein they are operating. Traditionally, ignition retard has been used to reduce the light-off time of the catalyst. This is however associated with a fuel penalty. With increasing vehicle electrification, electrically heating facilities present an alternative, especially for hybrid vehicles. Nevertheless, system complexity of hybrid vehicles prevents engineers to evaluate possible heating technologies and their corresponding fuel penalty with respect to traditional solutions. This paper evaluates the application of an electrically heated catalyst on a hybrid vehicle equipped with a Natural Gas (NG) engine. The effect of heating power on light-off time and fuel penalty is determined, using analysis techniques emerging from integrated powertrain control. By means of a case study, the importance of an integral approach is explained by comparing the fuel penalty and conversion efficiency improvement of electric heating with that of ignition retard. In this process, a mix of simulation and test data were combined, forming the foundations for future control developments of a suitable light-off strategy. © 2010 Institut francais du petrole.