S. Z. Mohammadi, Farideh Mousazadeh, Maryam Mohammadhasani-Pour
{"title":"改性丝网印刷电极对叶酸的电化学检测","authors":"S. Z. Mohammadi, Farideh Mousazadeh, Maryam Mohammadhasani-Pour","doi":"10.5599/jese.1360","DOIUrl":null,"url":null,"abstract":"In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chronoamperemetry (CHA) were used for the detection of folic acid at Ni-BTC MOF modified SPE. The results indicate that the as-prepared sensor has a good electrocatalytic effect on the detection of folic acid. This electrochemical sensor showed a dynamic linear response range from 0.08 to 635.0 µM and the detection limit was estimated to be 0.03±0.001 µM. Moreover, the feasibility of Ni-BTC MOF/SPE sensor to detect folic acid in real samples was also evaluated by the standard addition method.","PeriodicalId":15660,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"12 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2022-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Electrochemical detection of folic acid using a modified screen printed electrode\",\"authors\":\"S. Z. Mohammadi, Farideh Mousazadeh, Maryam Mohammadhasani-Pour\",\"doi\":\"10.5599/jese.1360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chronoamperemetry (CHA) were used for the detection of folic acid at Ni-BTC MOF modified SPE. The results indicate that the as-prepared sensor has a good electrocatalytic effect on the detection of folic acid. This electrochemical sensor showed a dynamic linear response range from 0.08 to 635.0 µM and the detection limit was estimated to be 0.03±0.001 µM. Moreover, the feasibility of Ni-BTC MOF/SPE sensor to detect folic acid in real samples was also evaluated by the standard addition method.\",\"PeriodicalId\":15660,\"journal\":{\"name\":\"Journal of Electrochemical Science and Engineering\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2022-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrochemical Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5599/jese.1360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.1360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
Electrochemical detection of folic acid using a modified screen printed electrode
In this work, an electrochemical sensor was established for the detection of folic acid based on Ni-BTC (BTC = benzene-1,3,5-tricarboxylic acid) metal-organic framework (MOF) modified screen-printed electrode (SPE). Electrochemical techniques (cyclic voltammetry (CV), differential pulse voltammetry (DPV), linear sweep voltammetry (LSV) and chronoamperemetry (CHA) were used for the detection of folic acid at Ni-BTC MOF modified SPE. The results indicate that the as-prepared sensor has a good electrocatalytic effect on the detection of folic acid. This electrochemical sensor showed a dynamic linear response range from 0.08 to 635.0 µM and the detection limit was estimated to be 0.03±0.001 µM. Moreover, the feasibility of Ni-BTC MOF/SPE sensor to detect folic acid in real samples was also evaluated by the standard addition method.