{"title":"基于阳离子表面活性剂的石墨烯片电化学传感器用于阿托伐他汀的灵敏检测","authors":"Vinoda B. Patil ,&nbsp;Shweta J. Malode ,&nbsp;Suresh M. Tuwar ,&nbsp;Nagaraj P. Shetti","doi":"10.1016/j.sintl.2022.100198","DOIUrl":null,"url":null,"abstract":"<div><p>The present work investigates the electrochemical studies of atorvastatin (ATRV) by establishing graphene (GR) and cationic surfactant cetyltrimethylammonium bromide (CTAB) based electrochemical sensor (GR-CTAB/CPE). The morphological study of a modifier was executed utilizing the electronic scanning microscopy (SEM) technique. GR-CTAB/CPE was identified as a supersensitive electrode for the identification of ATRV, as the electrochemical sensor exhibited enhanced electrocatalytic property and increased peak current in pH 4.2 of phosphate buffer solution employing voltammetric approaches like cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The impact of pre-concentration time, supporting electrolyte (pH), scan rate, and concentration was examined. The number of protons and electrons involved in the electro-oxidative mechanism of ATRV was depicted. The ATRV at the developed sensor has a limit of detection of 2.46 ​× ​10<sup>−9</sup> ​M. The proposed method was proven effective in determining ATRV concentration in clinical and biological samples. The data obtained from the recovery studies suggests that the GR-CTAB/CPE was selective and highly sensible in identifying ATRV.</p></div>","PeriodicalId":21733,"journal":{"name":"Sensors International","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666351122000432/pdfft?md5=745f64aa47a79e0ac8bbc11d6c189406&pid=1-s2.0-S2666351122000432-main.pdf","citationCount":"10","resultStr":"{\"title\":\"Graphene sheet-based electrochemical sensor with cationic surfactant for sensitive detection of atorvastatin\",\"authors\":\"Vinoda B. Patil ,&nbsp;Shweta J. Malode ,&nbsp;Suresh M. Tuwar ,&nbsp;Nagaraj P. Shetti\",\"doi\":\"10.1016/j.sintl.2022.100198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The present work investigates the electrochemical studies of atorvastatin (ATRV) by establishing graphene (GR) and cationic surfactant cetyltrimethylammonium bromide (CTAB) based electrochemical sensor (GR-CTAB/CPE). The morphological study of a modifier was executed utilizing the electronic scanning microscopy (SEM) technique. GR-CTAB/CPE was identified as a supersensitive electrode for the identification of ATRV, as the electrochemical sensor exhibited enhanced electrocatalytic property and increased peak current in pH 4.2 of phosphate buffer solution employing voltammetric approaches like cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The impact of pre-concentration time, supporting electrolyte (pH), scan rate, and concentration was examined. The number of protons and electrons involved in the electro-oxidative mechanism of ATRV was depicted. The ATRV at the developed sensor has a limit of detection of 2.46 ​× ​10<sup>−9</sup> ​M. The proposed method was proven effective in determining ATRV concentration in clinical and biological samples. The data obtained from the recovery studies suggests that the GR-CTAB/CPE was selective and highly sensible in identifying ATRV.</p></div>\",\"PeriodicalId\":21733,\"journal\":{\"name\":\"Sensors International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666351122000432/pdfft?md5=745f64aa47a79e0ac8bbc11d6c189406&pid=1-s2.0-S2666351122000432-main.pdf\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666351122000432\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666351122000432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

本工作通过建立石墨烯(GR)和阳离子表面活性剂十六烷基三甲基溴化铵(CTAB)为基础的电化学传感器(GR-CTAB/CPE),对阿托伐他汀(ATRV)进行了电化学研究。利用电子扫描显微镜(SEM)技术对改性剂进行了形态学研究。采用循环伏安法(CV)和差分脉冲伏安法(DPV)等伏安方法,发现GR-CTAB/CPE在pH为4.2的磷酸盐缓冲溶液中表现出更强的电催化性能和更高的峰值电流,因此被认为是一种用于ATRV鉴定的超敏感电极。考察了预浓缩时间、支持电解质(pH)、扫描速率和浓度的影响。描述了参与ATRV电氧化机制的质子数和电子数。该传感器的ATRV检测限为2.46 × 10−9 M。所提出的方法被证明是有效的测定ATRV浓度在临床和生物样品。从恢复研究中获得的数据表明,GR-CTAB/CPE在识别ATRV方面具有选择性和高度敏感性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Graphene sheet-based electrochemical sensor with cationic surfactant for sensitive detection of atorvastatin

The present work investigates the electrochemical studies of atorvastatin (ATRV) by establishing graphene (GR) and cationic surfactant cetyltrimethylammonium bromide (CTAB) based electrochemical sensor (GR-CTAB/CPE). The morphological study of a modifier was executed utilizing the electronic scanning microscopy (SEM) technique. GR-CTAB/CPE was identified as a supersensitive electrode for the identification of ATRV, as the electrochemical sensor exhibited enhanced electrocatalytic property and increased peak current in pH 4.2 of phosphate buffer solution employing voltammetric approaches like cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The impact of pre-concentration time, supporting electrolyte (pH), scan rate, and concentration was examined. The number of protons and electrons involved in the electro-oxidative mechanism of ATRV was depicted. The ATRV at the developed sensor has a limit of detection of 2.46 ​× ​10−9 ​M. The proposed method was proven effective in determining ATRV concentration in clinical and biological samples. The data obtained from the recovery studies suggests that the GR-CTAB/CPE was selective and highly sensible in identifying ATRV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
17.40
自引率
0.00%
发文量
0
期刊最新文献
A method to detect enzymatic reactions with field effect transistor Blue luminescent carbon quantum dots derived from diverse banana peels for selective sensing of Fe(III) ions The application of ultrasonic measurement and machine learning technique to identify flow regime in a bubble column reactor A capacitive sensor-based approach for type-2 diabetes detection via bio-impedance analysis of erythrocytes GA-mADAM-IIoT: A new lightweight threats detection in the industrial IoT via genetic algorithm with attention mechanism and LSTM on multivariate time series sensor data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1